Shaking Table Testing of a Scaled Nuclear Power Plant Structure with Base Isolation

被引:0
|
作者
Song, Linlin [1 ,2 ]
Zhang, Xueming [1 ,2 ]
Wei, Mingyang [1 ,2 ]
Sun, Yunlun [3 ]
Chen, Shicai [4 ]
Chen, Yan [3 ]
机构
[1] Shijiazhuang Tiedao Univ, Minist Educ, Key Lab Rd & Railway Engn Safety Control, Shijiazhuang 050043, Peoples R China
[2] Shijiazhuang Tiedao Univ, State Key Lab Mech Behav & Syst, Safety Traff Engn Struct, Shijiazhuang 050043, Peoples R China
[3] Chinergy Co Ltd, Beijing 100193, Peoples R China
[4] Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
SEISMIC ISOLATION; RISK-ASSESSMENT; SYSTEMS;
D O I
10.1155/2023/2536474
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To investigate the seismic performance and isolation effect of a high-temperature gas-cooled reactor, a 1/20 scale model including a reactor, a spent-fuel plant, and a nuclear auxiliary plant was fabricated. In addition, 220 mm lead-rubber bearings were designed and produced for use in the shaking table test, which included both isolated and nonisolated conditions. Two historical earthquake records and three artificial earthquake motions were used to input the ground motion in the tests. The results demonstrated that the seismic performance of the plant was better and that the structure was in an elastic state, under a safe shutdown earthquake event. Isolation bearings were found to effectively reduce the dominate frequency of the structure. The acceleration amplification factor of the superstructure was found to be less than 1. The isolation test results showed that the peak of the floor response spectrum at the pressure vessel support was less than 0.1 g. In the nonisolation test, the peak of the floor response spectrum was greater than 1 g. In the isolation test, the relative displacement of the structure was less than 1.1 mm, which was relatively small. The structure maintained a good isolation performance and exhibited improved safety under extreme ground motion.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Shaking table tests on base-isolated nuclear power plant
    Wang, Tao
    Wang, Fei
    Hou, Gang-Ling
    Ding, Lu-Tong
    Gongcheng Lixue/Engineering Mechanics, 2014, 31 (10): : 62 - 68
  • [2] Theoretical analysis of bearings in tension and shaking table tests on a base-isolated nuclear power plant structure
    Liu W.
    Cheng Y.
    Li S.
    Yang J.
    He W.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2019, 38 (14): : 153 - 160
  • [3] Scaled Soil-Structure Interaction Model for Shaking Table Testing
    Goktepe, F.
    Omid, A. J.
    Celebi, E.
    ACTA PHYSICA POLONICA A, 2017, 132 (03) : 588 - 590
  • [4] Shaking table tests on failure characteristics of base isolation system for a DFBR plant
    Sato, N
    Kato, A
    Fukushima, Y
    Iizuka, M
    NUCLEAR ENGINEERING AND DESIGN, 2002, 212 (1-3) : 293 - 305
  • [5] Shaking table testing of a scaled wind turbine structure model considering soil-structure interaction
    Ding, Yanqiong
    Nie, Minggang
    Xu, Yazhou
    Bai, Guoliang
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2024, 57 (10): : 25 - 32
  • [6] SHAKING TABLE TEST FOR BASE-ISOLATED NUCLEAR ISLAND STRUCTURE MODEL
    Yang Jie
    Li ShaoPing
    Yuan Fang
    Xia ZuFeng
    Huang XiaoLin
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 2, 2017,
  • [7] Shaking table testing on a scaled semi-active controlled three-dimensional floor isolation system
    Shi Y.-D.
    Du Y.
    Han Q.-H.
    Wei X.
    Wu H.
    Liu M.-J.
    Tang Z.-Y.
    Gongcheng Lixue/Engineering Mechanics, 2021, 38 (07): : 99 - 107and119
  • [8] Shaking table test study of nuclear power plant model considering soil-structure interaction effect
    Zhao, Jinyi
    Chen, Hao
    Zhou, Zhiguang
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 168
  • [9] The Application of base isolation in a power plant structure
    Fu, Yanwei
    3RD INTERNATIONAL CONFERENCE ON AIR POLLUTION AND ENVIRONMENTAL ENGINEERING, 2020, 631
  • [10] SHAKING-TABLE STUDY OF BASE ISOLATION FOR MASONRY BUILDINGS
    PAULSON, TJ
    ABRAMS, DP
    MAYES, RL
    JOURNAL OF STRUCTURAL ENGINEERING, 1991, 117 (11) : 3315 - 3336