Safety and feasibility study of a novel robotic system in an in vivo porcine vascular model

被引:1
|
作者
Moschovaki-Zeiger, Ornella [1 ]
Arkoudis, Nikolaos-Achilleas [1 ]
Spiliopoulos, Stavros [1 ]
机构
[1] Natl & Kapodistrian Univ Athens, Attikon Univ Gen Hosp, Med Sch, Dept Radiol 2,Intervent Radiol Unit, 1st Rimini St, GR-12461 Athens, Greece
关键词
Robotics; Endovascular intervention; Visceral catheterization; Remote intervention; Robotic-assisted intervention; TECHNOLOGY; TUMORS; BRAIN;
D O I
10.1186/s42155-024-00425-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeThe goal of this preclinical study is to assess the functionality, technical feasibility, and safety of a new vascular robotic LIBERTYR 3 System, in the microcatheterization of vascular targets using a range of guidewires and microcatheters.Material and methodsAn anesthetized pig served as an arterial model for the robotic device (LIBERTYR3; Microbot Medical Ltd, Yoqneam, IL). The primary efficacy endpoint was the evaluation of its capability to selectively catheterize predetermined distal arterial branches in the liver, kidneys, and mesenteric arteries (technical success), under fluoroscopy guidance. The primary safety endpoint was the occurrence of angiographic acute catheterization-related complications (dissection, thrombosis, embolism, perforation). The catheterizations were conducted by two interventional radiologists that present different work experience in endovascular procedures (18 and 2 years respectively), using a variety of microcatheters and wires. Various procedural parameters such as functionality, practicality, ease of use, and time required for selective catheterization, were evaluated, and recorded.ResultsAll pre-determined arteries were successfully selectively catheterized (100% technical success), by both operators. No angiographic acute complications occurred. The microcatheters and wires were manipulated using the remote portable console in an effortless manner that maintained a high level of accuracy. Mean time for selective catheterization was 131 +/- 82 s. The robot's conversion function to manual operation was successfully demonstrated.ConclusionRobotic navigation and catheterization of selected target arteries were accomplished without observable vascular damage, suggesting that the LIBERTYR 3 robotic system is a reliable and safe tool for robotic-assisted endovascular navigation. Further experimental studies are required to evaluate safety and efficacy prior to introduction into clinical practice.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Feasibility and safety of a novel in vivo model to assess playground falls in children
    Ehrlich, Peter F.
    Young, Justin G.
    Ulin, Sheryl
    Wooley, Charles
    Armstrong, Thomas J.
    Buschmann, Bethany
    Galecki, Andrzej
    Ashton-Miller, James A.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2013, 75 (01): : 54 - 59
  • [22] Safety and Feasibility of Electrochemotherapy of the Pancreas in a Porcine Model
    Dezman, Rok
    Cemazar, Maja
    Sersa, Gregor
    Seliskar, Alenka
    Erjavec, Vladimira
    Trotovsek, Blaz
    Gasljevic, Gorana
    Bosnjak, Masa
    Tratar, Ursa Lampreht
    Kos, Bor
    Djokic, Mihajlo
    Milevoj, Nina
    Stukelj, Marina
    Boc, Nina
    Izlakar, Jani
    Popovic, Peter
    PANCREAS, 2020, 49 (09) : 1168 - 1173
  • [23] Feasibility study evaluating a magnetic marker in an ex-vivo porcine model
    Peek, Mirjam C. L.
    Zada, Ali
    Ahmed, Muneer
    Baker, Rose
    Sekino, Masaki
    Kusakabe, Moriaki
    Douek, Michael
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2018, 460 : 334 - 339
  • [24] Initial experience with the novel modular robotic system Carina in urology: a prospective study on safety feasibility and surgical settings
    Gaurab Pokhrel
    ZeYuan Wang
    Jinshan Cui
    Bingzhai Jin
    Haoke Zheng
    Jin Tao
    Yafeng Fan
    Yunlong Liu
    Yonghao Zhan
    Shuanbao Yu
    Biao Dong
    Xuepei Zhang
    Scientific Reports, 15 (1)
  • [25] Evaluation of a Novel Cryoablation System In vivo Testing in a Chronic Porcine Model
    Weimar, Timo
    Lee, Anson M.
    Ray, Shuddhadeb
    Schuessler, Richard B.
    Damiano, Ralph J., Jr.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2012, 7 (06) : 410 - 416
  • [26] Feasibility and safety of Stanford A aortic dissection complete endovascular repair system in a porcine model
    Peng, Yucheng
    Lin, Wenhui
    Lou, Deda
    Luo, Songyuan
    Li, Bo
    Su, Mingcheng
    Liu, Jitao
    Tang, Yue
    Luo, Jianfang
    BMC CARDIOVASCULAR DISORDERS, 2023, 23 (01)
  • [27] Feasibility and safety of Stanford A aortic dissection complete endovascular repair system in a porcine model
    Yucheng Peng
    Wenhui Lin
    Deda Lou
    Songyuan Luo
    Bo Li
    Mingcheng Su
    Jitao Liu
    Yue Tang
    Jianfang Luo
    BMC Cardiovascular Disorders, 23
  • [28] Feasibility and Safety of Robotic Peripheral Vascular Interventions Results of the RAPID Trial
    Mahmud, Ehtisham
    Schmid, Florian
    Kalmar, Peter
    Deutschmann, Hannes
    Hafner, Franz
    Rief, Peter
    Brodmann, Marianne
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (19) : 2058 - 2064
  • [29] Novel Robotic Valvuloplastic Esophagogastrostomy Technique After Proximal Gastrectomy: A Safety and Feasibility Study
    Amini, Neda
    Kinoshita, Takahiro
    Arrieta, Manuel
    Yoshida, Mitsumasa
    Nagata, Hiromi
    Habu, Takumi
    Komatsu, Masaru
    Yura, Masahiro
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2025, 35 (02):
  • [30] A novel Robotic Gait Training System (RGTS) may facilitate functional recovery after stroke: A feasibility and safety study
    Lin, Li-Fong
    Huang, Shih-Wei
    Chang, Kwang-Hwa
    Ouyang, Jin-Han
    Liou, Tsan-Hon
    Lin, Yen-Nung
    NEUROREHABILITATION, 2017, 41 (02) : 453 - 461