Safety and feasibility study of a novel robotic system in an in vivo porcine vascular model

被引:1
|
作者
Moschovaki-Zeiger, Ornella [1 ]
Arkoudis, Nikolaos-Achilleas [1 ]
Spiliopoulos, Stavros [1 ]
机构
[1] Natl & Kapodistrian Univ Athens, Attikon Univ Gen Hosp, Med Sch, Dept Radiol 2,Intervent Radiol Unit, 1st Rimini St, GR-12461 Athens, Greece
关键词
Robotics; Endovascular intervention; Visceral catheterization; Remote intervention; Robotic-assisted intervention; TECHNOLOGY; TUMORS; BRAIN;
D O I
10.1186/s42155-024-00425-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeThe goal of this preclinical study is to assess the functionality, technical feasibility, and safety of a new vascular robotic LIBERTYR 3 System, in the microcatheterization of vascular targets using a range of guidewires and microcatheters.Material and methodsAn anesthetized pig served as an arterial model for the robotic device (LIBERTYR3; Microbot Medical Ltd, Yoqneam, IL). The primary efficacy endpoint was the evaluation of its capability to selectively catheterize predetermined distal arterial branches in the liver, kidneys, and mesenteric arteries (technical success), under fluoroscopy guidance. The primary safety endpoint was the occurrence of angiographic acute catheterization-related complications (dissection, thrombosis, embolism, perforation). The catheterizations were conducted by two interventional radiologists that present different work experience in endovascular procedures (18 and 2 years respectively), using a variety of microcatheters and wires. Various procedural parameters such as functionality, practicality, ease of use, and time required for selective catheterization, were evaluated, and recorded.ResultsAll pre-determined arteries were successfully selectively catheterized (100% technical success), by both operators. No angiographic acute complications occurred. The microcatheters and wires were manipulated using the remote portable console in an effortless manner that maintained a high level of accuracy. Mean time for selective catheterization was 131 +/- 82 s. The robot's conversion function to manual operation was successfully demonstrated.ConclusionRobotic navigation and catheterization of selected target arteries were accomplished without observable vascular damage, suggesting that the LIBERTYR 3 robotic system is a reliable and safe tool for robotic-assisted endovascular navigation. Further experimental studies are required to evaluate safety and efficacy prior to introduction into clinical practice.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Safety and feasibility study of a novel robotic system in an in vivo porcine vascular model
    Ornella Moschovaki-Zeiger
    Nikolaos-Achilleas Arkoudis
    Stavros Spiliopoulos
    CVIR Endovascular, 7
  • [2] Robotic Renal Autotransplantation: A Feasibility Study in a Porcine Model
    Kubota, Risa
    Araki, Motoo
    Wada, Koichiro
    Kawamura, Kasumi
    Maruyama, Yuki
    Mitsui, Yosuke
    Sadahira, Takuya
    Ariyoshi, Yuichi
    Iwata, Takehiro
    Nishimura, Shingo
    Takamoto, Atsushi
    Sako, Tomoko
    Edamura, Kohei
    Kobayashi, Yasuyuki
    Kano, Yuzuki
    Kitagawa, Masashi
    Tanabe, Katsuyuki
    Sugiyama, Hitoshi
    Wada, Jun
    Watanabe, Masami
    Watanabe, Toyohiko
    Nasu, Yasutomo
    ACTA MEDICA OKAYAMA, 2020, 74 (01) : 53 - 58
  • [3] How Safe Are the Laparoscopic and Robotic Graspers? Evaluation of the Novel Avatera Robotic Surgical System: An Acute In Vivo Study on a Porcine Model
    Tatanis, Vasileios
    Natsos, Anastasios
    Tsaturyan, Arman
    Vagionis, Athanasios
    Peteinaris, Angelis
    Faitatziadis, Solon
    Gkeka, Kristiana
    Pagonis, Konstantinos
    Obaidat, Mohammed
    Anaplioti, Eirini
    Koumoundourou, Dimitra
    Bravou, Vassiliki
    Vrettos, Theofanis
    Kallidonis, Panagiotis
    Liatsikos, Evangelos
    UROLOGY RESEARCH AND PRACTICE, 2023, 49 (06) : 387 - 391
  • [4] Feasibility and safety of a novel 3D-printed biodegradable biliary stent in an in vivo porcine model: a preliminary study
    Jae Hyun Kim
    Dong-Heon Ha
    Eui Soo Han
    YoungRok Choi
    Jiwon Koh
    Ijin Joo
    Jung Hoon Kim
    Dong-Woo Cho
    Joon Koo Han
    Scientific Reports, 12
  • [5] Feasibility and safety of a novel 3D-printed biodegradable biliary stent in an in vivo porcine model: a preliminary study
    Kim, Jae Hyun
    Ha, Dong-Heon
    Han, Eui Soo
    Choi, YoungRok
    Koh, Jiwon
    Joo, Ijin
    Kim, Jung Hoon
    Cho, Dong-Woo
    Han, Joon Koo
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [6] Feasibility Study of a Novel Transapical Chordal Implantation System in a Porcine Model
    Lu, Yuntao
    Chen, Jinmiao
    Yin, Minyan
    Yang, Ye
    Wang, Wenshuo
    Dong, Lili
    Song, Wenyu
    Meng, Jian
    Zhou, Qingliang
    Wei, Lai
    INTERNATIONAL HEART JOURNAL, 2024, 65 (01) : 128 - 134
  • [7] Feasibility Study of a Novel Transcatheter Tricuspid Annuloplasty System in a Porcine Model
    Pan, Wenzhi
    Long, Yuliang
    Zhang, Xiaochun
    Chen, Shasha
    Li, Wei
    Pan, Cuizhen
    Guo, Yingqiang
    Zhou, Daxin
    Ge, Junbo
    JACC-BASIC TO TRANSLATIONAL SCIENCE, 2022, 7 (06): : 600 - 607
  • [8] Robot-Assisted Radical Nephrectomy Using the Novel Avatera Robotic Surgical System: A Feasibility Study in a Porcine Model
    Gkeka, Kristiana
    Tsaturyan, Arman
    Faitatziadis, Solon
    Peteinaris, Angelis
    Anaplioti, Eirini
    Pagonis, Konstantinos
    Vagionis, Athanasios
    Tatanis, Vasileios
    Vrettos, Theofanis
    Kallidonis, Panagiotis
    Liatsikos, Evangelos
    JOURNAL OF ENDOUROLOGY, 2023, 37 (03) : 273 - 278
  • [9] Feasibility study of a novel robotic system for transperitoneal partial nephrectomy An in vivo experimental animal study
    Faitatziadis, Solon
    Tatanis, Vasileios
    Katsakiori, Paraskevi
    Peteinaris, Angelis
    Gkeka, Kristiana
    Vagionis, Athanasios
    Spinos, Theodoros
    Tsaturyan, Arman
    Vrettos, Theofanis
    Kallidonis, Panagiotis
    Stolzenburg, Jens-Uwe
    Liatsikos, Evangelos
    ARCHIVIO ITALIANO DI UROLOGIA E ANDROLOGIA, 2023, 95 (04) : 11852
  • [10] IN VIVO FEASIBILITY TEST USING FLEXIBLE URETEROSCOPIC ROBOTIC SYSTEM, EASYURETERO FOR RENAL STONE RETRIEVAL IN PORCINE MODEL
    Han, Hyun Ho
    Moon, Young Joon
    Jung, Hae Do
    Kim, Joonhwan
    Cheon, Byungsik
    Han, Jungmin
    Cho, Sung Yong
    Kwon, Dong-Soo
    Lee, Joo Yong
    JOURNAL OF UROLOGY, 2022, 207 (05): : E202 - E202