Femoral Neck System versus Three Cannulated Screws for Fixation of Femoral Neck Fractures in Younger Patients: A Retrospective Cohort Study

被引:5
|
作者
Yan, Shuang G. [1 ]
Cui, Yiliang [1 ]
Li, Di [2 ,6 ]
Liu, Fanxiao [3 ]
Hua, Xingyi [1 ]
Schmidutz, Florian [4 ,5 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Orthopaed Surg, Hefei, Peoples R China
[2] Naval Med Univ, Changhai Hosp, Affiliated Hosp 1, Dept Orthopaed Surg, Shanghai, Peoples R China
[3] Shandong First Med Univ, Shandong Prov Hosp, Dept Orthopaed, Jinan, Peoples R China
[4] Univ Hosp Munich LMU, Dept Orthopaed Surg Phys Med & Rehabil, Munich, Germany
[5] Ortho Zentrum Rosenheim, Rosenheim, Germany
[6] Naval Med Univ, Changhai Hosp, Dept Orthopaed Surg, Shanghai, Peoples R China
关键词
Cannulated cancellous screws; femoral neck fracture; femoral neck system; internal fixation; ADULTS; HIP;
D O I
10.1080/08941939.2023.2266752
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To compare the clinical results of a new femoral neck system (FNS) and cannulated compression screws (CCS) for the treatment of femoral neck fractures in younger patients.Methods: Retrospective study was performed in younger patients with femoral neck fractures that were treated with FNS or CCS from August 2017 to August 2022. The hip functional outcomes were assessed with the Harris hip score (HHS). Secondary outcomes included the surgical time, surgical blood loss, satisfaction visual analog scale (VAS), fluoroscopy frequency, fracture healing time and complications.Results: A total of 49 patients (22 FNS and 27 CCS) with a minimum follow-up of 12 months were included. There was also no significant difference in HHSs (p = 0.27) and satisfaction VAS (p = 0.10) between them. Patients with FNS had more blood loss (50.45 +/- 5.28 mL vs. 20.67 +/- 4.71 ml, p < 0.01), lower fluoroscopy frequency (16.64 +/- 3.32 vs. 23.59 +/- 3.39, p < 0.01) and lower fracture healing time (3.76 +/- 0.42 vs. 4.46 +/- 0.59 months, p < 0.01). The femoral neck shortening and incidence of nail withdrawal in the FNS group was significantly lower than CCS group (2.91 +/- 1.95 vs. 4.44 +/- 1.52 mm, p < 0.01; 4.5% vs. 22.2%, p = 0.03).Conclusions: The FNS and CCS get similar hip functions. The FNS can reduce fluoroscopy exposure and the complications such as femoral neck shortening and nail withdrawal. Thus, FNS can be an alternative to CCS for the fixation of femoral neck fractures in younger patients.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Comparison of the clinical efficacy of a femoral neck system versus cannulated screws in the treatment of femoral neck fracture in young adults
    He, Changjun
    Lu, Yao
    Wang, Qian
    Ren, Cheng
    Li, Ming
    Yang, Mingyi
    Xu, Yibo
    Li, Zhong
    Zhang, Kun
    Ma, Teng
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [42] Arthroplasty Versus Internal Fixation for the Treatment of Undisplaced Femoral Neck Fractures: A Retrospective Cohort Study
    Afaq, Shaikh
    O'Hara, Nathan N.
    Schemitsch, Emil H.
    Bzovsky, Sofia
    Sprague, Sheila
    Poolman, Rudolf W.
    Frihagen, Frede
    Heels-Ansdell, Diane
    Bhandari, Mohit
    Swiontkowski, Marc
    Slobogean, Gerard P.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 : S9 - S14
  • [43] Is there an increased risk for subtrochanteric stress fracture with the Femoral Neck System versus multiple cannulated screws fixation?
    Hsu, Megan R.
    Shu, Henry T.
    Luksameearunothai, Kitchai
    Margalit, Adam
    Yu, Andrew T.
    Hasenboehler, Erik A.
    Shafiq, Babar
    JOURNAL OF ORTHOPAEDICS, 2022, 30 : 127 - 133
  • [44] Percutaneous cannulated screw fixation of femoral neck fractures: The three point principle
    Bout, CA
    Cannegieter, DM
    Juttmann, JW
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (02): : 135 - 139
  • [45] Femoral neck system (FNS) versus 4 cannulated compression screws (CCSs) in the treatment of young patients with Pauwels type III femoral neck fracture: a retrospective comparative study
    Gao, Yang
    Ma, Tianle
    Chang, Xiaohu
    Jia, Peng
    Li, Xiaoteng
    Tang, Xin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [46] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Zheng Wang
    Yong Yang
    Gangning Feng
    Haohui Guo
    Zhirong Chen
    Yaogeng Chen
    Qunhua Jin
    BioMedical Engineering OnLine, 21
  • [47] Comparison of Femoral Neck System Versus Cannulated Cancellous Screws for the Fixation of Femoral Neck Fracture in Young Adults: A Systematic Review and Meta-Analysis
    Gupta, Govind K.
    Rai, Arpita
    Mandal, Subhankar
    Rani, Sudha
    Shekhar, Shubhendu
    Halder, Subhajit
    Prasad, Pancham
    Kumar, Amit
    Ul Haque, Zeya
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
  • [48] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Wang, Zheng
    Yang, Yong
    Feng, Gangning
    Guo, Haohui
    Chen, Zhirong
    Chen, Yaogeng
    Jin, Qunhua
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [49] Biomechanical comparison of femoral neck system and cannulated screws coupled with medial plate for treating Pauwels III femoral neck fractures
    Nan, Chong
    Li, Yanjun
    Liu, Yuxiu
    Ma, Liang
    Ma, Zhanbei
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (04) : 1161 - 1170
  • [50] Multiple screws versus sliding hip screws in femoral neck fractures A protocol of cohort study
    Zhao, Yu
    Yin, Kun
    Zhao, Huiling
    Peng, Zeli
    MEDICINE, 2020, 99 (27) : E20970