Femoral Neck System versus Three Cannulated Screws for Fixation of Femoral Neck Fractures in Younger Patients: A Retrospective Cohort Study

被引:5
|
作者
Yan, Shuang G. [1 ]
Cui, Yiliang [1 ]
Li, Di [2 ,6 ]
Liu, Fanxiao [3 ]
Hua, Xingyi [1 ]
Schmidutz, Florian [4 ,5 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Orthopaed Surg, Hefei, Peoples R China
[2] Naval Med Univ, Changhai Hosp, Affiliated Hosp 1, Dept Orthopaed Surg, Shanghai, Peoples R China
[3] Shandong First Med Univ, Shandong Prov Hosp, Dept Orthopaed, Jinan, Peoples R China
[4] Univ Hosp Munich LMU, Dept Orthopaed Surg Phys Med & Rehabil, Munich, Germany
[5] Ortho Zentrum Rosenheim, Rosenheim, Germany
[6] Naval Med Univ, Changhai Hosp, Dept Orthopaed Surg, Shanghai, Peoples R China
关键词
Cannulated cancellous screws; femoral neck fracture; femoral neck system; internal fixation; ADULTS; HIP;
D O I
10.1080/08941939.2023.2266752
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To compare the clinical results of a new femoral neck system (FNS) and cannulated compression screws (CCS) for the treatment of femoral neck fractures in younger patients.Methods: Retrospective study was performed in younger patients with femoral neck fractures that were treated with FNS or CCS from August 2017 to August 2022. The hip functional outcomes were assessed with the Harris hip score (HHS). Secondary outcomes included the surgical time, surgical blood loss, satisfaction visual analog scale (VAS), fluoroscopy frequency, fracture healing time and complications.Results: A total of 49 patients (22 FNS and 27 CCS) with a minimum follow-up of 12 months were included. There was also no significant difference in HHSs (p = 0.27) and satisfaction VAS (p = 0.10) between them. Patients with FNS had more blood loss (50.45 +/- 5.28 mL vs. 20.67 +/- 4.71 ml, p < 0.01), lower fluoroscopy frequency (16.64 +/- 3.32 vs. 23.59 +/- 3.39, p < 0.01) and lower fracture healing time (3.76 +/- 0.42 vs. 4.46 +/- 0.59 months, p < 0.01). The femoral neck shortening and incidence of nail withdrawal in the FNS group was significantly lower than CCS group (2.91 +/- 1.95 vs. 4.44 +/- 1.52 mm, p < 0.01; 4.5% vs. 22.2%, p = 0.03).Conclusions: The FNS and CCS get similar hip functions. The FNS can reduce fluoroscopy exposure and the complications such as femoral neck shortening and nail withdrawal. Thus, FNS can be an alternative to CCS for the fixation of femoral neck fractures in younger patients.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients
    Hu, Huaijian
    Cheng, Jingbo
    Feng, Mingli
    Gao, Zhihua
    Wu, Jingwei
    Lu, Shibao
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [2] Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients
    Huaijian Hu
    Jingbo Cheng
    Mingli Feng
    Zhihua Gao
    Jingwei Wu
    Shibao Lu
    Journal of Orthopaedic Surgery and Research, 16
  • [3] Comment on "Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients"
    Tang, Yunfeng
    Wang, Guangling
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [4] Comment on “Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients”
    Yunfeng Tang
    Guangling Wang
    Journal of Orthopaedic Surgery and Research, 16
  • [5] Comparison of femoral neck system versus cannulated cancellous screws for the fixation of femoral neck fracture: a single-center retrospective cohort study
    Caldaria, A.
    Gambuti, E.
    Biagi, N.
    Spadoni, E.
    Saracco, A.
    Massari, L.
    Caruso, G.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, : 3207 - 3213
  • [6] Fixation of femoral neck fractures using divergent versus parallel cannulated screws
    Papanastassiou I.D.
    Mavrogenis A.F.
    Kokkalis Z.T.
    Nikolopoulos K.
    Skourtas K.
    Papagelopoulos P.J.
    Journal of Long-Term Effects of Medical Implants, 2011, 21 (01) : 63 - 69
  • [7] Letter to the editor regarding "Comparison of femoral neck system versus cannulated cancellous screws for the fixation of femoral neck fracture: a single-center retrospective cohort study"
    Pan, Zhicheng
    Liu, Wangxin
    Zhang, Qi
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (06): : 3215 - 3216
  • [8] Cannulated screws fixation as an alternative treatment of femoral neck osteoporotic fractures
    Ciesielczyk, B
    Tuchocka-Piotrowska, A
    ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 : 516 - +
  • [9] Fixation of femoral neck fracture with femoral neck system: a retrospective cohort study of 43 patients
    Jae Youn Yoon
    Seong-Eun Byun
    Young-Ho Cho
    BMC Musculoskeletal Disorders, 25
  • [10] Fixation of femoral neck fracture with femoral neck system: a retrospective cohort study of 43 patients
    Yoon, Jae Youn
    Byun, Seong-Eun
    Cho, Young-Ho
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)