Non-enzymatic glucose sensor using nanostructured copper oxide thin films deposited by spray pyrolysis

被引:10
|
作者
Martinez-Saucedo, G. [1 ]
Ugalde-Reygadas, M. [2 ]
Pena, J. J. Alcantar [1 ]
Lastra-Medina, G. [1 ,2 ]
Marquez-Marin, J. [2 ]
Torres-Delgado, G. [2 ]
Castanedo-Perez, R. [2 ]
Chavez-Urbiola, I. R. [1 ]
机构
[1] Ctr Ingn & Desarrollo Ind, Ave Playa Pie de la Cuesta 702, Santiago De Queretaro 76125, Queretaro, Mexico
[2] IPN, Unidad Queretaro, Ctr Invest & Estudios Avanzados, Queretaro 76230, Qro, Mexico
关键词
Glucose sensor; Biosensor; Thin film; Copper oxides; NANOWIRE ARRAYS; NANOPARTICLES; ELECTRODE;
D O I
10.1016/j.surfin.2023.102702
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Thin-film thickness effect on glucose sensitivity for a non-enzymatic sensor is affected by two main factors, film ' s conductivity, and roughness. The thin-film thickness effect is studied with copper oxide films grown by spray pyrolysis. The film is deposited with thickness in the 83 <= tau film <= 892 nm range on a nickel electrode and employed for glucose sensing in a three-electrode system as a working electrode. As the film thickness increases up to 434 nm, the signal stability and sensibility improve. For a greater thickness, the glucose sensibility starts to decrease smoothly. The sensibility increment from the thinnest film to our best condition is twofold from 0.25 to 0.47 mAmM-1/cm2, and a lineal behavior is observed for a wide glucose concentration range of 0-8 mM. This work shows that a simple solution-based technique such as spray pyrolysis can be employed to obtain functional glucose sensors.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Performances presented by zinc oxide thin films deposited by spray pyrolysis
    Nunes, P
    Fernandes, B
    Fortunato, E
    Vilarinho, P
    Martins, R
    THIN SOLID FILMS, 1999, 337 (1-2) : 176 - 179
  • [32] Highly sensitive non-enzymatic glucose sensor with copper oxide nanoparticle impregnated mesoporous silica
    Anees Y. Khan
    Rajdip Bandyopadhyaya
    Journal of Porous Materials, 2021, 28 : 1097 - 1104
  • [33] Highly sensitive non-enzymatic glucose sensor with copper oxide nanoparticle impregnated mesoporous silica
    Khan, Anees Y.
    Bandyopadhyaya, Rajdip
    JOURNAL OF POROUS MATERIALS, 2021, 28 (04) : 1097 - 1104
  • [34] Non-Enzymatic Glucose Sensor Based on a Copper Oxide Nanoflowers Electrode Decorated with Pt Nanoparticles
    Song, Min-Jung
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2018, 56 (05): : 705 - 710
  • [35] A Non-Enzymatic Glucose Sensor based on Copper Oxide Nanowires-SingleWall Carbon Nanotubes
    Bao, Jing
    Hou, Changjun
    Zhang, Yuchan
    Li, Qiong
    Huo, Danqun
    Yang, Mei
    Luo, Xiaogang
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (03) : B47 - B51
  • [36] Non-Enzymatic Amperometric Glucose Sensor Based on Carbon Nanodots and Copper Oxide Nanocomposites Electrode
    Sridara, Tharinee
    Upan, Jantima
    Saianand, Gopalan
    Tuantranont, Adisorn
    Karuwan, Chanpen
    Jakmunee, Jaroon
    SENSORS, 2020, 20 (03)
  • [37] Non-enzymatic Amperometric Glucose Sensor Based on Copper Nanowires Decorated Reduced Graphene Oxide
    Ju, Lele
    Wu, Guosong
    Lu, Biao
    Li, Xiaoyun
    Wu, Huaping
    Liu, Aiping
    ELECTROANALYSIS, 2016, 28 (10) : 2543 - 2551
  • [38] Synthesis and characterizations of biscuit-like copper oxide for the non-enzymatic glucose sensor applications
    Velmurugan, Murugan
    Karikalan, Natarajan
    Chen, Shen-Ming
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2017, 493 : 349 - 355
  • [39] Growth of Copper Oxide Thin Films Deposited by Ultrasonic-Assisted Spray Pyrolysis Deposition Method
    Han, In Sub
    Park, Il-Kyu
    KOREAN JOURNAL OF MATERIALS RESEARCH, 2018, 28 (09): : 516 - 521
  • [40] Fabrication of non-enzymatic glucose sensor dependent upon Au nanoparticles deposited on carboxylated graphene oxide
    Dilmac, Yusuf
    Guler, Muhammet
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 864