Comparing Real-Time Continuous Glucose Monitoring to Self-Monitoring of Blood Glucose: Advantages and Limitations for Children and Adolescents With Type 1 Diabetes

被引:1
|
作者
Aljuhani, Reyof [1 ]
Adas, Merna [1 ]
Alnaami, Raghad [1 ]
Alshehri, Reham [1 ]
Alqarni, Rahaf [1 ]
NoorSaeed, Sundus [2 ]
Al-Agha, Abdulmoein [3 ]
机构
[1] King Abdulaziz Univ Hosp, Med, Jeddah, Saudi Arabia
[2] King Abdulaziz Univ, Pediat, Jeddah, Saudi Arabia
[3] King Abdulaziz Univ Hosp, Pediat, Jeddah, Saudi Arabia
关键词
hypoglycemia; glycemic control; t1d; smbg; rtcgm;
D O I
10.7759/cureus.51496
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We aimed to determine the benefits and drawbacks of real-time continuous glucose monitoring (rtCGM) compared with those of self-monitoring of blood glucose (SMBG) in children and adolescents with type 1 diabetes (T1D) and their impact on glycemic control, hypo-and hyperglycemic episodes, exercise, quality of life, and psychosocial factors. Methodology This quantitative, comparative, cross-sectional study was conducted between July 2022 and March 2023 at the Pediatric Endocrine Outpatient Clinic, King Abdulaziz University Hospital, Saudi Arabia. Data were obtained via a clinical interview with children and adolescents with T1D aged 2-18 years. Results The study involved 121 participants, with 71 (58.7%) male patients and 50 (41.3%) female patients. The participants' mean age was 11.9 +/- 4.4 years. Compared with patients using SMBG, patients using rtCGM demonstrated a more significant decrease in the mean glycated hemoglobin (HbA1c) level from baseline (7.79 +/- 1.17 vs. 8.92 +/- 1.63, P = 0.001), a reduction in the number of hypoglycemic episodes (85.7% vs. 70.6%, P = 0.028), and stable blood glucose level during exercise (97.2% vs. 76.4%, P = 0.001). Additionally, 65 (92.9%) rtCGM users had undisturbed sleep compared with 22 (43.1%) SMBG users. Approximately 64 (91.4%) rtCGM users reported that the sensor helped decrease their anxiety levels and pain sensations. Conclusions In this novel study in Saudi Arabia, rtCGM demonstrated a significantly better impact than SMBG on glycemic control, hypo-and hyperglycemic episodes, and psychosocial factors in children and adolescents with T1D.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Cost-utility of real-time continuous glucose monitoring versus self-monitoring of blood glucose in people with insulin-treated Type 2 diabetes in Canada
    Alshannaq, Hamza
    Isitt, John J.
    Pollock, Richard F.
    Norman, Gregory J.
    Cogswell, Greg
    Lynch, Peter M.
    Roze, Stephane
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2023, 12 (10)
  • [22] Cost-utility of real-time continuous glucose monitoring versus self-monitoring of blood glucose in people with insulin-treated Type II diabetes in France
    Alshannaq, Hamza
    Pollock, Richard F.
    Joubert, Michael
    Ahmed, Waqas
    Norman, Gregory J.
    Lynch, Peter M.
    Roze, Stephane
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2024, 13 (03)
  • [23] Cost-Effectiveness of a Real-Time Continuous Glucose Monitoring System vs. Self-Monitoring of Blood Glucose in Type 2 Diabetes Patients on Insulin in Canada
    Isitt, John J.
    Roze, Stephane
    Cogswell, Gregory
    Lynch, Peter M.
    DIABETES, 2022, 71
  • [24] COST-EFFECTIVENESS OF A REAL-TIME CONTINUOUS GLUCOSE MONITORING SYSTEM VERSUS SELF-MONITORING OF BLOOD GLUCOSE IN TYPE 2 DIABETES PATIENTS ON INSULIN IN THE UNITED KINGDOM
    Isitt, J.
    Roze, S.
    Leelarathna, L.
    Cogswell, G.
    Norman, G.
    Lynch, P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A32 - A33
  • [25] Randomized comparison of the metabolic effect of continuous glucose monitoring system (CGMS) and self-monitoring blood glucose (SMBG) in children with type 1 diabetes
    Deiss, DA
    Hartmann, R
    Schmidt, J
    Kordonouri, O
    DIABETES, 2004, 53 : A460 - A461
  • [26] Effects of continuous glucose monitoring versus self-monitoring of blood glucose among adults with type 2 diabetes
    Zheng, M.
    Luo, Y.
    Khoja, A.
    Lin, W.
    Hu, P.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2022, 186
  • [27] Comparison of flash glucose monitoring with real time continuous glucose monitoring in children and adolescents with type 1 diabetes treated with continuous subcutaneous insulin infusion
    Massa, Guy G.
    Gys, Inge
    Bevilacqua, Esmiralda
    Wijnands, Anne
    Zeevaert, Renate
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2019, 152 : 111 - 118
  • [28] Self-monitoring of blood glucose in children and teens with diabetes
    Bui, H
    Perlman, K
    Daneman, D
    PEDIATRIC DIABETES, 2005, 6 (01) : 50 - 62
  • [29] Self-monitoring of blood glucose in type 2 diabetes
    Lowe, Julia
    AUSTRALIAN PRESCRIBER, 2010, 33 (05) : 138 - 140
  • [30] Self-monitoring of blood glucose for type 2 diabetes
    Bloomgarden, Zachary
    Ning, Guang
    JOURNAL OF DIABETES, 2015, 7 (05) : 593 - 594