A glassy carbon electrode modified with a composite consisting of electrodeposited chitosan and carboxylated multi-walled carbon nanotubes for simultaneous voltammetric determination of dopamine, serotonin and melatonin

被引:12
|
作者
Tang, Shanshan [1 ]
Liang, Axin [1 ]
Liu, Miao [1 ]
Wang, Wei [1 ]
Zhang, Fulai [1 ]
Luo, Aiqin [1 ]
机构
[1] Beijing Inst Technol, Sch Life Sci, Key Lab Mol Med & Biotherapy, Beijing 100081, Peoples R China
关键词
Electrochemical sensor; Simultaneous detection; MWCNTs; Electrodeposited chitosan; ASCORBIC-ACID; HYDROQUINONE; CATECHOL;
D O I
10.1007/s42823-023-00556-6
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A glassy carbon electrode modified with a composite consisting of electrodeposited chitosan and carboxylated multi-walled carbon nanotubes (e-CS/MWCNTs/GCE) was used as a working electrode for simultaneous determination of dopamine (DA), serotonin (5-HT) and melatonin (MT), which were related to circadian rhythms. The electrochemical characterizations of the working electrode were carried out via electrochemical impedance spectroscopy and chronocoulometry. It was found that electrochemical modification method, that was cyclic voltammetry, may can cause continuous CS polymerization on MWCNTs surface to form a dense membrane with more active sites on the electrode, and the electrochemically active surface area of e-CS/MWCNTs/GCE obtained was about 7 times that of GCE. The electrochemical behaviour of DA, 5-HT and MT on working electrode were carried out via differential pulse voltammetry and cyclic voltammetry. The results showed that e-CS/MWCNTs/GCE solved the problem that the bare electrode could not detect three substances simultaneously, and can catalyze oxidation potential difference as low as 0.17 V of two substances reaction at the same time, indicating very good electrocatalytic activity. By optimizing the detection conditions, the sensor showed a good linear response to DA, 5-HT and MT in the range of 20-1000 mu mol/L, 9-1000 mu mol/L and 20-1000 mu mol/L, and the detection limits were 12 mu mol/L, 10 mu mol/L and 22 mu mol/L (S/N = 3), respectively. In addition, the proposed sensor was successfully applied to the simultaneous detection of DA, 5-HT and MT in human saliva samples.
引用
收藏
页码:2129 / 2139
页数:11
相关论文
共 50 条
  • [21] A Highly Sensitive Modified Glassy Carbon Electrode with a Carboxylated Multi-walled Carbon Nanotubes/Nafion Nano Composite for Voltammetric Sensing of Dianabol in Biological Fluid
    Alourfi, Nouf M.
    Mohammed, Gharam I.
    Nassef, Hossam M.
    Alwael, Hassan
    Bahaidarah, Effat A.
    Bashammakh, Abdulaziz S.
    Mujawar, Liyakat H.
    El-Shahawi, Mohammad S.
    Analytical Sciences, 2021, 37 (12): : 1795 - 1802
  • [22] Rapid Detection of Semicarbazide Based on Glassy Carbon Electrode Modified with Carboxylated Multi-Walled Carbon Nanotubes
    He Bao-Shan
    Du Geng-An
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (10) : 1511 - 1516
  • [23] Multi-walled carbon nanotubes modified glassy carbon electrode for sensitive determination of ketoconazole
    Borowiec, Joanna
    Wei, Lili
    Zhu, Lihua
    Zhang, Jingdong
    ANALYTICAL METHODS, 2012, 4 (02) : 444 - 448
  • [24] An application of a glassy carbon electrode and a glassy carbon electrode modified with multi-walled carbon nanotubes in electroanalytical determination of oxycarboxin
    Leniart, Andrzej
    Brycht, Mariola
    Burnat, Barbara
    Skrzypek, Sawomira
    IONICS, 2018, 24 (07) : 2111 - 2121
  • [25] An application of a glassy carbon electrode and a glassy carbon electrode modified with multi-walled carbon nanotubes in electroanalytical determination of oxycarboxin
    Andrzej Leniart
    Mariola Brycht
    Barbara Burnat
    Sławomira Skrzypek
    Ionics, 2018, 24 : 2111 - 2121
  • [26] Voltammetric determination of resorcinol on the surface of a glassy carbon electrode modified with multi-walled carbon nanotube
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsem
    Hajisadeghian, Elahe
    Golestaneh, Mahshid
    ARABIAN JOURNAL OF CHEMISTRY, 2016, 9 : S1563 - S1568
  • [27] Voltammetric determination of antibacterial drug gemifloxacin in solubilized systems at multi-walled carbon nanotubes modified glassy carbon electrode
    Jain, Rajeev
    Rather, Jahangir Ahmad
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 83 (02) : 340 - 346
  • [28] Electrochemical Determination of Dopamine at Pre-Anodized Helical Multi-Walled Carbon Nanotubes Modified Glassy Carbon Electrode
    Li, Zhiguo
    Jia, Yongmei
    Liu, Yuge
    Ye, Cui
    Hua, Guifang
    Zhong, Yiping
    Zhang, Lingling
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (02)
  • [29] A Novel Glassy Carbon Electrode Modified with Multi-Walled Carbon Nanotubes for Potentiometric Xipamide Determination
    Tantawy, Mahmoud A.
    El Fiky, Haitham A.
    Badawey, Amr M.
    Ghany, Maha F. Abd El
    Fares, Nermine, V
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (05)
  • [30] Electrochemical properties and the determination of nicotine at a multi-walled carbon nanotubes modified glassy carbon electrode
    Huayu Xiong
    Yunfei Zhao
    Peng Liu
    Xiuhua Zhang
    Shengfu Wang
    Microchimica Acta, 2010, 168 : 31 - 36