Clinical and radiologic outcomes of Lima ProMade custom 3D-printed glenoid components in primary and revision reverse total shoulder arthroplasty with severe glenoid bone loss: a minimum 2-year follow-up

被引:4
|
作者
Rashid, Mustafa S. [1 ]
Cunningham, Lindsay [1 ]
Shields, David W. [1 ]
Walton, Michael J. [1 ]
Monga, Puneet [1 ]
Bale, Richard S. [1 ]
Trail, Ian A. [1 ]
机构
[1] Wrightington Hosp, Dept Orthopaed Surg, Wigan, Lancs, England
关键词
Custom; 3D-printed; complex; shoulder; replacement; arthroplasty; revision; HEMIARTHROPLASTY;
D O I
10.1016/j.jse.2023.04.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of this study is to report the clinical and radiologic outcomes of patients undergoing primary or revision reverse total shoulder arthroplasty using custom 3D-printed components to manage severe glenoid bone loss with a minimum of 2-year follow-up.Methods: Following ethical approval, patients were identified and invited to participate. Inclusion criteria were (1) severe glenoid bone loss necessitating the need for custom implants and (2) patients with definitive glenoid and humeral components implanted more than 2 years prior. Included patients underwent clinical assessment using the Oxford Shoulder Score (OSS), Constant-Murley score, American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), and the quick Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH). Radiographic assessment included anteroposterior and axial projections. Patients were invited to attend a computed tomography (CT) scan to confirm osseointegration. Statistical analysis used descriptive statistics (mean and standard deviation [SD]) and paired t test for parametric data.Results: Eleven patients declined to participate. Five patients were deceased prior to study commencement, leaving 42 remaining pa-tients in this analysis. Three patients had revision surgery before the 2-year follow-up; of these, 2 retained their custom glenoid com-ponents. Mean follow-up was 31.6 months from surgery (range 24-52 months). All 4 scores improved: OSS from a mean 15 (SD 8.4) to 36 (SD 12) (P < .001), Constant-Murley score from a mean 15 (SD 11.2) to 52 (SD 20.1) (P < .001), QuickDASH from a mean 70 (SD 21) to 31 (SD 24.8) (P = .004), and the ASES score from a mean 22 (SD 17.8) to 71 (SD 23.3) (P = .007). Radiologic evaluation demonstrated good osseointegration in all but 1 included patient.Conclusion: The utility of custom 3D-printed components for managing severe glenoid bone loss in primary and revision reverse total shoulder arthroplasty yields significant clinical improvements in this complex cohort. Large complex glenoid bone defects can be managed successfully with custom 3D-printed glenoid components.
引用
收藏
页码:2017 / 2026
页数:10
相关论文
共 48 条
  • [41] Tibial implant varus >3° does not adversely affect outcomes or revision rates in functionally aligned image-based robotic total knee arthroplasty in a minimum of 2-year follow-up
    Koutserimpas, Christos
    Garibaldi, Riccardo
    Olivier, Flora
    Servien, Elvire
    Batailler, Cecile
    Lustig, Sebastien
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2025,
  • [42] Use of Customized 3D-Printed Titanium Augment With Tantalum Trabecular Cup for Large Acetabular Bone Defects in Revision Total Hip Arthroplasty: A Midterm Follow-Up Study
    Kong, Keyu
    Zhao, Chen
    Chang, Yongyun
    Qiao, Hua
    Hu, Yi
    Li, Huiwu
    Zhang, Jingwei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [43] The use of bilobed porous-coated acetabular components without structural bone graft for type III acetabular defects in revision total hip arthroplasty - A prospective study with a minimum 2-year follow-up
    Moskal, JT
    Shen, FH
    JOURNAL OF ARTHROPLASTY, 2004, 19 (07): : 867 - 873
  • [44] Reverse Total Shoulder Arthroplasty for Treatment of 3- and 4-Part Proximal Humeral Fractures: Clinical and Radiological Analysis With Minimum Follow-Up of 2 Years
    Barbosa, Luis
    Pires, Luis
    Rego, Paulo
    Alonso, Raul
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2020, 11
  • [45] A new 3D printing porous trabecular titanium metal acetabular cup for primary total hip arthroplasty: a minimum 2-year follow-up of 92 consecutive patients
    Xiao Geng
    Yang Li
    Feng Li
    Xinguang Wang
    Ke Zhang
    Zhongjun Liu
    Hua Tian
    Journal of Orthopaedic Surgery and Research, 15
  • [46] Clinical Outcomes of Two-Stage Implantation in Reverse Shoulder Arthroplasty for Postinfectious End-Stage Glenohumeral Arthritis in Native Shoulders: A Single-Center Cohort Study with a Minimum 2-Year Follow-up
    Bilgin, Emre
    Tezgel, Okan
    Ucan, Vahdet
    Kapicioglu, Mehmet
    Turgut, Ali
    Bilsel, Kerem
    CLINICS IN ORTHOPEDIC SURGERY, 2023, 15 (02) : 272 - 280
  • [47] A new 3D printing porous trabecular titanium metal acetabular cup for primary total hip arthroplasty: a minimum 2-year follow-up of 92 consecutive patients (vol 15, 383, 2020)
    Geng, Xiao
    Li, Yang
    Li, Feng
    Wang, Xinguang
    Zhang, Ke
    Liu, Zhongjun
    Tian, Hua
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [48] Revision hip arthroscopy for hip synovial chondromatosis is effective despite inferior postoperative clinical outcomes compared to patients undergoing primary hip arthroscopy: a matched control study with minimum 2-year follow-up
    Zhu, Yichuan
    Zhang, Xin
    Wang, Jianquan
    Gao, Guanying
    Xu, Yan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):