Multi-objective optimization for capacity matching and energy performance of heat-pump-driven liquid-desiccant air-conditioning system

被引:8
|
作者
Lee, Jae-Hee [1 ]
Cheon, Seong-Yong [1 ]
Jeong, Jae-Weon [1 ]
机构
[1] Hanyang Univ, Coll Engn, Dept Architectural Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
基金
新加坡国家研究基金会;
关键词
Liquid desiccant; Heat pump; Capacity matching; Energy performance; Multi-objective optimization; DESIGN OPTIMIZATION; MASS-TRANSFER; DEHUMIDIFICATION; EFFICIENCY; HUMIDITY;
D O I
10.1016/j.applthermaleng.2023.120615
中图分类号
O414.1 [热力学];
学科分类号
摘要
In heat-pump-driven liquid-desiccant (HPLD) air-conditioning systems, releasing condensing heat from heat pump to regenerator solution and exhaust air (i.e., capacity matching) is important for maintaining dehumidi-fication performance, operational feasibility, and system stability. Therefore, this study optimizes capacity matching, especially focusing on releasing extra condensing heat, which has simply been assumed to be well-treated in previous studies, in conjunction with energy performance. With four design variables under various outdoor air conditions, a multi-objective optimization is conducted to simultaneously maximize system coeffi-cient of performance (COP) and minimize a newly defined capacity-matching index of extra condenser. Pareto front, a set of optimum points, is obtained using a multi-objective genetic algorithm. Final optimum solutions are then determined and discussed based on a decision-making scenario. In optimization results, the regenerator air and solution flow rates should be respectively greater and lower than those of the absorber. The optimum temperature of absorber inlet solution is generally distributed at approximately 18 degrees C, while that of regenerator inlet solution is significantly influenced by the decision-making scenario. Finally, the system COP was maximally increased by 24 %, and the capacity-matching index of extra condenser was maximally decreased by 55 %, compared with each initial value.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Multi-objective optimization of the HVAC (heating, ventilation, and air conditioning) system performance
    Wei, Xiupeng
    Kusiak, Andrew
    Li, Mingyang
    Tang, Fan
    Zeng, Yaohui
    ENERGY, 2015, 83 : 294 - 306
  • [42] Comparison of Modelled and Measured Heat and Mass Transfer in a Liquid Desiccant Air-Conditioning System
    Mandow, Wael
    Muetzel, Martin
    Fleig, Daniel
    Lowenstein, Andrew
    Jordan, Ulrike
    PROCEEDINGS OF THE ISES EUROSUN 2018 CONFERENCE - 12TH INTERNATIONAL CONFERENCE ON SOLAR ENERGY FOR BUILDINGS AND INDUSTRY, 2018, : 648 - 658
  • [43] Multi absorber stand alone liquid desiccant air-conditioning systems for higher performance
    Kumar, Ritunesh
    Dhar, P. L.
    Jain, Sanjeev
    Asati, A. K.
    SOLAR ENERGY, 2009, 83 (05) : 761 - 772
  • [44] R744 heat pump driven liquid desiccant air conditioning system for hot and humid climates
    Reddy, Y. Siva Kumar
    Guruchethan, A. M.
    Kochunni, Sarun Kumar
    Singh, Simarpreet
    Maiya, M. P.
    Hafner, Armin
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 56
  • [45] Performance optimization of a heat pump driven liquid desiccant dehumidification system using exergy analysis
    Zhang, Qinling
    Liu, Xiaohua
    Zhang, Tao
    Xie, Ying
    ENERGY, 2020, 204
  • [46] Four E analysis and multi-objective optimization of an ice thermal energy storage for air-conditioning applications
    Sanaye, Sepehr
    Shirazi, Alec
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2013, 36 (03) : 828 - 841
  • [47] Study on noncondensing air-conditioning system performance when combining a desiccant cooling system with a CO2 heat pump
    Tsay, Yaw-Shyan
    Kato, Shinsuke
    Ooka, Ryozo
    Koganei, Makoto
    Nishida, Kousaku
    Kawamoto, Koichi
    HVAC&R RESEARCH, 2006, 12 (3C): : 917 - 933
  • [48] Efficiency and performance evaluation of a novel EV Air-conditioning and battery cooling system with desiccant-coated heat pump
    Zadeh, Peyman Gholamali
    Chung, Jae Dong
    APPLIED THERMAL ENGINEERING, 2025, 264
  • [49] Study on technology of potential energy storage in liquid desiccant cooling air-conditioning system
    Jiang Yi
    Zhang Xiaosong
    Yin Yonggao
    Jae, Won Young
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 405 - +
  • [50] Multi-objective Capacity Optimization of Integrated Energy System with Compressed Air Energy Storage
    Wang, Haiyang
    Li, Ke
    Zhang, Chenghui
    Ma, Xin
    PROCEEDINGS OF THE 15TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2020), 2020, : 484 - 489