Multi-objective optimization for capacity matching and energy performance of heat-pump-driven liquid-desiccant air-conditioning system

被引:8
|
作者
Lee, Jae-Hee [1 ]
Cheon, Seong-Yong [1 ]
Jeong, Jae-Weon [1 ]
机构
[1] Hanyang Univ, Coll Engn, Dept Architectural Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
基金
新加坡国家研究基金会;
关键词
Liquid desiccant; Heat pump; Capacity matching; Energy performance; Multi-objective optimization; DESIGN OPTIMIZATION; MASS-TRANSFER; DEHUMIDIFICATION; EFFICIENCY; HUMIDITY;
D O I
10.1016/j.applthermaleng.2023.120615
中图分类号
O414.1 [热力学];
学科分类号
摘要
In heat-pump-driven liquid-desiccant (HPLD) air-conditioning systems, releasing condensing heat from heat pump to regenerator solution and exhaust air (i.e., capacity matching) is important for maintaining dehumidi-fication performance, operational feasibility, and system stability. Therefore, this study optimizes capacity matching, especially focusing on releasing extra condensing heat, which has simply been assumed to be well-treated in previous studies, in conjunction with energy performance. With four design variables under various outdoor air conditions, a multi-objective optimization is conducted to simultaneously maximize system coeffi-cient of performance (COP) and minimize a newly defined capacity-matching index of extra condenser. Pareto front, a set of optimum points, is obtained using a multi-objective genetic algorithm. Final optimum solutions are then determined and discussed based on a decision-making scenario. In optimization results, the regenerator air and solution flow rates should be respectively greater and lower than those of the absorber. The optimum temperature of absorber inlet solution is generally distributed at approximately 18 degrees C, while that of regenerator inlet solution is significantly influenced by the decision-making scenario. Finally, the system COP was maximally increased by 24 %, and the capacity-matching index of extra condenser was maximally decreased by 55 %, compared with each initial value.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Inactivation of airborne microbial contaminants by a heat-pump-driven liquid-desiccant air-conditioning system
    Lee, Jae-Hee
    Bang, Jong-Il
    Sung, Minki
    Jeong, Jae-Weon
    JOURNAL OF BUILDING ENGINEERING, 2022, 50
  • [2] Hybrid heat-pump-driven liquid-desiccant system: Experimental performance analysis for residential air-conditioning applications
    Lee, Jae-Hee
    Jeong, Jae-Weon
    Applied Thermal Engineering, 2021, 195
  • [3] Hybrid heat-pump-driven liquid-desiccant system: Experimental performance analysis for residential air-conditioning applications
    Lee, Jae-Hee
    Jeong, Jae-Weon
    APPLIED THERMAL ENGINEERING, 2021, 195
  • [4] Optimization of solution concentration in liquid desiccant air-conditioning system driven by heat pump
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    ENERGY AND BUILDINGS, 2020, 225
  • [5] Investigation on capacity matching in liquid desiccant and heat pump hybrid air-conditioning systems
    Niu, Xiaofeng
    Xiao, Fu
    Ma, Zhenjun
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (01): : 160 - 170
  • [6] Simulation on a liquid-desiccant air conditioning system without pump
    Zhao, Wei
    Zhu, Ruiqi
    Kan, Yisong
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2002, 36 (01): : 30 - 34
  • [7] Optimization of NTUm allocation between dehumidifier and regenerator in liquid-desiccant air-conditioning system
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 127 : 250 - 259
  • [8] Dynamic model and response characteristics of liquid desiccant air-conditioning system driven by heat pump
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    Wang, Andong
    BUILDING SIMULATION, 2021, 14 (06) : 1773 - 1784
  • [9] Dynamic model and response characteristics of liquid desiccant air-conditioning system driven by heat pump
    Bowen Guan
    Xiaohua Liu
    Tao Zhang
    Andong Wang
    Building Simulation, 2021, 14 : 1773 - 1784
  • [10] ENERGY SAVING IN A HEAT PUMP AIR-CONDITIONING SYSTEM USING LIQUID DESICCANT AND MEMBRANE CONTACTORS
    Bergero, Stefano
    Chiari, Anna
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 1, 2012, : 869 - 878