Culturable airborne fungi communities in naturally ventilated indoor spaces of old residential buildings in Poland

被引:2
|
作者
Kacprzak, Malgorzata [1 ]
Stolarska, Magdalena [2 ]
Lis, Piotr [2 ]
机构
[1] Warsaw Univ Technol, Inst Civil Engn, Fac Civil Engn Mech & Petrochem, Plock, Poland
[2] Czestochowa Tech Univ, Fac Infrastruct & Environm Engn, Czestochowa, Poland
关键词
Culturable fungi; indoor space; natural ventilation; carbon dioxide; microclimate; seasonal variation; OUTDOOR AIR; ENVIRONMENTS; BACTERIAL;
D O I
10.1177/01436244231205363
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The fungal communities inhabiting apartments inmultifamily buildings (N = 33 apartments) with natural ventilation were determined during seasonal variation in the south part of Poland (Silesia region). Itwas found that the average level of CO2 concentration usually not exceeded 1000 ppm. The minimal value was noted in November - 402 ppm, however the maximal concentration was equal 6156 ppm and obtained in June. The average fungal colony forming units (CFU/m(3)) was calculated as follows: 1.06 x 10(2) (February), 1.17 x 10(2) (June) and 2.98 x 10(2) (November). The most frequently occurred species/genera: yeast and yeast-like fungi, Aspergillus niger, Penicillium spp., Cladosporium cladosporioides, Rhodotorula rubra; Culvaraia lunata, Dematiaceae family, Ulocladium consortiale, Verticillium spp.; Fusarium spp., Alternaria alternata; Oidiodendron griseum. The cluster analysis showed no mutual similarity between communities of air fungi isolated from bathrooms of all studied apartments as well as between communities isolated from other indoor spaces (rooms, kitchens, halls). This suggests that natural ventilation has no (or minimal effect) on the propagation of fungal spores between apartments. Statistically significant positive correlation between the concentration of fungi in the air and external humidity, carbon dioxide levels (February, November), and external temperature (November) were found. Practical application: This study provides that natural ventilation has no effect on the spread of fungal spores inside the building and are not contributed to increase of fungal airborne health risk transmission. It also shows evidence of seasonal changes in carbon dioxide in multi-family homes with natural ventilation. This may give input to establish CO2 benchmark data in such type of buildings.
引用
收藏
页码:659 / 675
页数:17
相关论文
共 50 条
  • [21] Profile and distribution characteristics of culturable airborne fungi in residential homes with children in Beijing, China
    Fang, Zhiguo
    Tang, Qingqing
    Gong, Chanjuan
    Ouyang, Zhiyun
    Liu, Peng
    Sun, Li
    Wang, Xiaoyong
    INDOOR AND BUILT ENVIRONMENT, 2017, 26 (09) : 1232 - 1242
  • [22] RNN-based forecasting of indoor temperature in a naturally ventilated residential building
    Weng, Kui
    Mourshed, Monjur
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 3103 - 3108
  • [23] A study of the effectiveness of passive climate control in naturally ventilated residential buildings in Singapore
    Wong, N. H.
    Li, S.
    BUILDING AND ENVIRONMENT, 2007, 42 (03) : 1395 - 1405
  • [24] An optimised window control strategy for naturally ventilated residential buildings in warm climates
    Tan, Zijing
    Deng, Xiang
    SUSTAINABLE CITIES AND SOCIETY, 2020, 57
  • [25] Development of a metamodel to assess building thermal performance for naturally ventilated residential buildings
    Veiga, Rodolfo Kirch
    Eli, Leticia Gabriela
    Krelling, Amanda Fraga
    Olinger, Marcelo Salles
    Melo, Ana Paula
    Lamberts, Roberto
    PROCEEDINGS OF BUILDING SIMULATION 2021: 17TH CONFERENCE OF IBPSA, 2022, 17 : 1849 - 1856
  • [26] The Effect Of Openings Type On Indoor Temperature Of Naturally Ventilated Buildings In The Tropical Climate
    Iqbal, Muhammad
    Atthaillah
    Nayan, Ahmad
    Indriani, Lena
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2025, 28 (08): : 1769 - 1777
  • [27] An investigation of indoor thermal environments and thermal comfort in naturally ventilated educational buildings
    de la Hoz-Torres, Maria Luisa
    Aguilar, Antonio J.
    Ruiz, Diego P.
    Martinez-Aires, Ma Dolores
    JOURNAL OF BUILDING ENGINEERING, 2024, 84
  • [28] Influence of weather and indoor climate on clothing of occupants in naturally ventilated school buildings
    de Carvalho, Paulo Matos
    da Silva, Manuel Gameiro
    Ramos, Joao Esteves
    BUILDING AND ENVIRONMENT, 2013, 59 : 38 - 46
  • [29] Comparison of indoor airborne spore collections in residential, commercial and school buildings
    Hu, F
    Barnes, CS
    Kusko, G
    Portnoy, J
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2002, 109 (01) : S54 - S54
  • [30] Temporal/seasonal variations of size-dependent airborne fungi indoor/outdoor relationships for a wind-induced naturally ventilated airspace
    Liao, CM
    Luo, WC
    Chen, SC
    Chen, JW
    Liang, HM