Analysis of the utility of transbronchial lung biopsy culture under endobronchial ultrasonography with a guide-sheath

被引:1
|
作者
Shimoda, Masafumi [1 ]
Morimoto, Kozo [1 ,2 ,3 ]
Tanaka, Yoshiaki [1 ]
Ito, Masashi [1 ]
Moue, Iori [1 ]
Yoshimori, Kozo [1 ]
Ohta, Ken [1 ]
机构
[1] Fukujuji Hosp, Resp Dis Ctr, Japan AntiTB Assoc JATA, 3-1-24 Mastuyama, Kiyose, Tokyo 2048522, Japan
[2] Fukujuji Hosp, Japan AntiTB Assoc, Div Clin Res, Kiyose, Tokyo, Japan
[3] Nagasaki Univ, Grad Sch Biomed Sci, Dept Clin Mycobacteriosis, Nagasaki, Japan
关键词
D O I
10.1038/s41598-023-43078-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Transbronchial lung biopsy (TBLB) culture is not common in clinical practice, and TBLB culture for patients with mycobacterial disease provide limited value because the diagnostic accuracy of TBLB culture is very low. Recently, bronchoscopic devices have been further developed, such as endobronchial ultrasonography with a guide-sheath (EBUS-GS). Therefore, this study investigated the utility of TBLB culture obtained by using EBUS-GS compared to washing cultures. A total of 31 patients who underwent TBLB culture by using EBUS-GS (GS-TBLB) were collected retrospectively at Fukujuji Hospital from January 2018 to December 2022. The diagnostic accuracies of GS-TBLB culture and bronchial and device washing cultures (namely, washing culture) were compared. The patients comprised 13 individuals with nontuberculous mycobacteriosis, 7 with pulmonary aspergillosis, 6 with lung abscess, and 5 with pulmonary tuberculosis. The diagnostic accuracy of GS-TBLB culture was lower to that of TBLB culture than those of washing culture (n = 11 [35.5%] vs. n = 20 [64.5%], p = 0.016), and there was only one patient with positive GS-TBLB culture results and negative washing culture results. Comparing between patients with mycobacteria and non-mycobacteria, GS-TBLB culture positivity were no significant difference between patients with mycobacteria and non-mycobacteria (n = 6 [33.3%] vs. n = 5 [38.5%], p = 1.000), however, patients with mycobacteria diagnosed by washing culture more than those with non-mycobacteria (n = 15 [83.3%] vs. n = 5 [38.5%], p = 0.021). Our results demonstrate that the utility of TBLB culture for the diagnosis of pulmonary infections might provide limited value even if EBUS-GS is performed and lung tissue is successfully obtained.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Utility of radial probe endobronchial ultrasound guided transbronchial lung biopsy
    Kim, Eun Jin
    Jung, Chi Young
    Kim, Kyung Chan
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [32] Combining transbronchial biopsy using endobronchial ultrasonography with a guide sheath and positron emission tomography for the diagnosis of small peripheral pulmonary lesions
    Mizugaki, Hidenori
    Shinagawa, Naofumi
    Kanegae, Kakuko
    Yamada, Noriyuki
    Asahina, Hajime
    Kikuchi, Eiki
    Oizumi, Satoshi
    Tamaki, Nagara
    Nishimura, Masaharu
    LUNG CANCER, 2010, 68 (02) : 211 - 215
  • [33] Diagnosis of Peripheral Pulmonary Lesions with Transbronchial Lung Cryobiopsy by Guide Sheath and Radial Endobronchial Ultrasonography: A Prospective Control Study
    Jiang, Ling
    Xu, Jian
    Liu, Chunfang
    Gao, Na
    Zhao, Jing
    Han, Xue
    Zhang, Xiaolin
    Zhao, Xiaohui
    Liu, Yuan
    Wang, Weixue
    Zhao, Junjun
    CANADIAN RESPIRATORY JOURNAL, 2021, 2021
  • [34] Diagnostic Value and Safety of Addition of Transbronchial Needle Aspiration to Transbronchial Biopsy Through Endobronchial Ultrasonography Using a Guide Sheath Under Virtual Bronchoscopic Navigation for the Diagnosis of Peripheral Pulmonary Lesions
    Ito, Takayasu
    Nishida, Kazuki
    Iwano, Shingo
    Okachi, Shotaro
    Nakamura, Shota
    Morise, Masahiro
    Toyofumi, Chen Yoshikawa Fengshi
    Ishii, Makoto
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2024, 31 (04)
  • [35] Endobronchial Ultrasound-guided Sheath Placement to Guide Transbronchial Biopsy of Mediastinal Lymphadenopathy and Lung Mass A New Technique
    Harris, Kassem
    Bessich, Jamie
    Sterman, Daniel H.
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2015, 22 (02) : 158 - 161
  • [36] Safety of transbronchial lung biopsy using radial probe endobronchial ultrasound and a guide sheath performed by beginners learning the procedure
    Eom, Jung Seop
    Lee, Min Ki
    Mok, Jeong Ha
    Kim, Changhwan
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [37] Safety Of Transbronchial Lung Biopsy Using Radial Probe Endobronchial Ultrasound And A Guide Sheath During The Learning Curve Phase
    Mok, J.
    Na, H.
    Eom, J.
    Jo, E.
    Kim, M.
    Lee, K.
    Kim, K.
    Park, H.
    Lee, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [38] FACTORS INFLUENCING DIAGNOSTIC YIELD OF TRANSBRONCHIAL BIOPSY USING ENDOBRONCHIAL ULTRASONOGRAPHY WITH A GUIDE SHEATH (EBUS-GS) IN PERIPHERAL PULMONARY LESIONS
    Imaizumi, Kazuyoshi
    Minesawa, Tomoyuki
    Isogai, Sumito
    Okamura, Takuya
    Morikawa, Sayako
    Niwa, Yoshikazu
    Takeyama, Tomoko
    Mieno, Yuki
    Morishita, Mariko
    Uozu, Sakurako
    Hoshino, Tami
    Hayashi, Masamichi
    Nakanishi, Toru
    Okazawa, Mitsushi
    RESPIROLOGY, 2013, 18 : 56 - 56
  • [39] Endobronchial ultrasound-guided transbronchial biopsy with or without a guide sheath for peripheral pulmonary malignancy
    Huang, Chun-Ta
    Chang, Lih-Yu
    Chen, Chung-Yu
    Ruan, Sheng-Yuan
    Lin, Ching-Kai
    Tsai, Yi-Ju
    Ho, Chao-Chi
    Yu, Chong-Jen
    ERJ OPEN RESEARCH, 2021, 7 (03)
  • [40] SYSTEMATIC REVIEW OF ENDOBRONCHIAL ULTRASONOGRAPHY WITH GUIDE SHEATH
    Jarman, J. W.
    March, J.
    Goldstein, L. J.
    Liao, R.
    Kalsekar, I
    Khanna, R.
    Chitnis, A.
    VALUE IN HEALTH, 2018, 21 : S173 - S173