Quantitative performance of photon-counting CT at low dose: Virtual monochromatic imaging and iodine quantification

被引:15
|
作者
Vrbaski, Stevan [1 ,2 ,3 ]
Bache, Steve [2 ]
Rajagopal, Jayasai [1 ,4 ]
Samei, Ehsan [1 ,5 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[2] Univ Trieste, Dept Phys, Trieste, Italy
[3] Elettra Sincrotrone Trieste, Trieste, Italy
[4] NIH, Radiol & Imaging Sci, Clin Ctr, Bethesda, MD USA
[5] Duke Univ, Med Ctr, Dept Radiol, Clin Imaging Phys Grp, Durham, NC 27705 USA
基金
美国国家卫生研究院;
关键词
iodine quantification; photon-counting CT; virtual monochromatic imaging; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; ITERATIVE-RECONSTRUCTION; ACCURACY; ATTENUATION; IMAGES;
D O I
10.1002/mp.16583
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundQuantitative imaging techniques, such as virtual monochromatic imaging (VMI) and iodine quantification (IQ), have proven valuable diagnostic methods in several specific clinical tasks such as tumor and tissue differentiation. Recently, a new generation of computed tomography (CT) scanners equipped with photon-counting detectors (PCD) has reached clinical status. PurposeThis work aimed to investigate the performance of a new photon-counting CT (PC-CT) in low-dose quantitative imaging tasks, comparing it to an earlier generation CT scanner with an energy-integrating detector dual-energy CT (DE-CT). The accuracy and precision of the quantification across size, dose, material types (including low and high iodine concentrations), displacement from iso-center, and solvent (tissue background) composition were explored. MethodsQuantitative analysis was performed on two clinical scanners, Siemens SOMATOM Force and NAEOTOM Alpha using a multi-energy phantom with plastic inserts mimicking different iodine concentrations and tissue types. The tube configurations in the dual-energy scanner were 80/150Sn kVp and 100/150Sn kVp, while for PC-CT both tube voltages were set to either 120 or 140 kVp with photon-counting energy thresholds set at 20/65 or 20/70 keV. The statistical significance of patient-related parameters in quantitative measurements was examined using ANOVA and pairwise comparison with the posthoc Tukey honest significance test. Scanner bias was assessed in both quantitative tasks for relevant patient-specific parameters. ResultsThe accuracy of IQ and VMI in the PC-CT was comparable between standard and low radiation doses (p < 0.01). The patient size and tissue type significantly affect the accuracy of both quantitative imaging tasks in both scanners. The PC-CT scanner outperforms the DE-CT scanner in the IQ task in all cases. Iodine quantification bias in the PC-CT (-0.9 & PLUSMN; 0.15 mg/mL) at low doses in our study was comparable to that of DE-CT (range -2.6 to 1.5 mg/mL, published elsewhere) at a 1.7x higher dose, but the dose reduction severely biased DE-CT (4.72 & PLUSMN; 0.22 mg/mL). The accuracy in Hounsfield units (HU) estimation was comparable for 70 and 100 keV virtual imaging between scanners, but PC-CT was significantly underestimating virtual 40 keV HU values of dense materials in the phantom representing the extremely obese population. ConclusionsThe statistical analysis of our measurements reveals better IQ at lower radiation doses using new PC-CT. Although VMI performance was mostly comparable between the scanners, the DE-CT scanner quantitatively outperformed PC-CT when estimating HU values in the specific case of very large phantoms and dense materials, benefiting from increased X-ray tube potentials.
引用
收藏
页码:5421 / 5433
页数:13
相关论文
共 50 条
  • [21] Spectral photon-counting CT in cardiovascular imaging
    Sandfort, Veit
    Persson, Mats
    Pourmorteza, Amir
    Noel, Peter B.
    Fleischmann, Dominik
    Willemink, Martin J.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (03) : 218 - 225
  • [22] Development and Clinical Applications of a Virtual Imaging Framework for Optimizing Photon-counting CT
    Abadi, Ehsan
    McCabe, Cindy
    Harrawood, Brian
    Sotoudeh-Paima, Saman
    Segars, W. Paul
    Samei, Ehsan
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [23] Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT
    Oechsner, Tim
    Soschynski, Martin
    Schlett, Christopher L.
    Krauss, Tobias
    Schupppert, Christopher
    Mueller-Peltzer, Katharina
    Vecsey-Nagy, Milan
    Kravchenko, Dmitrij
    Varga-Szemes, Akos
    Emrich, Tilman
    Scheu, Raphael
    Taron, Jana
    Bamberg, Fabian
    Hagar, Muhammad Taha
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 183
  • [24] The potential of photon-counting CT for quantitative contrast-enhanced imaging in radiotherapy
    Simard, Mikael
    Lapointe, Andreanne
    Lalonde, Arthur
    Bahig, Houda
    Bouchard, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (11):
  • [25] Liver Iodine Quantification With Photon-Counting Detector CT: Accuracy in an Abdominal Phantom and Feasibility in Patients
    Sartoretti, Thomas
    Mergen, Victor
    Jungblut, Lisa
    Alkadhi, Hatem
    Euler, Andre
    ACADEMIC RADIOLOGY, 2023, 30 (03) : 461 - 469
  • [26] Performance of iodine quantification through high-pitch dual-source photon-counting CT: a phantom study
    Liu, Peng
    Zhou, Shanshui
    Dong, Haipeng
    Li, Jiqiang
    Xu, Zhihan
    Lin, Shushen
    Yang, Wenjie
    Yan, Fuhua
    Qin, Le
    JAPANESE JOURNAL OF RADIOLOGY, 2025, 43 (02) : 309 - 318
  • [27] Photon-Counting CT: Virtual Study, Real Benefit
    Menu, Yves
    RADIOLOGY, 2025, 314 (01)
  • [28] First-generation clinical dual-source photon-counting CT: ultra-low-dose quantitative spectral imaging
    Liu, Leening P.
    Shapira, Nadav
    Chen, Andrew A.
    Shinohara, Russell T.
    Sahbaee, Pooyan
    Schnall, Mitchell
    Litt, Harold, I
    Noel, Peter B.
    EUROPEAN RADIOLOGY, 2022, 32 (12) : 8579 - 8587
  • [29] Visual and Quantitative Evaluation of Low-Concentration Bismuth in Dual-Contrast Imaging of Iodine and Bismuth Using Clinical Photon-Counting CT
    Ataei, Afrouz
    Vasan, Vasantha
    Soesbe, Todd C.
    Brewington, Cecelia C.
    Zhou, Zhongxing
    Yu, Lifeng
    Hallam, Kristina A.
    Ren, Liqiang
    SENSORS, 2024, 24 (11)
  • [30] First-generation clinical dual-source photon-counting CT: ultra-low-dose quantitative spectral imaging
    Leening P. Liu
    Nadav Shapira
    Andrew A. Chen
    Russell T. Shinohara
    Pooyan Sahbaee
    Mitchell Schnall
    Harold I. Litt
    Peter B. Noël
    European Radiology, 2022, 32 : 8579 - 8587