Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty

被引:5
|
作者
Riechelmann, Felix [1 ]
Lettner, H. [2 ]
Mayr, R. [1 ]
Tandogan, R. [3 ,4 ]
Dammerer, D. [5 ]
Liebensteiner, M. [1 ]
机构
[1] Med Univ Innsbruck, Dept Orthopaed & Traumatol, Anichstr 35, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Anichstr 35, A-6020 Innsbruck, Austria
[3] Ortoklinik, Ankara, Turkiye
[4] Halic Univ, Dept Orthopaed & Traumatol, Istanbul, Turkiye
[5] Univ Hosp Krems, Krems, Austria
关键词
Total knee arthroplasty; Digital templating; Accuracy; EndoCert; Operative time; Storage cost; REPLACEMENT;
D O I
10.1007/s00402-023-04772-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTo analyze the match between preoperatively determined implant size (2D templating) and intraoperatively used implant size in total knee arthroplasty (TKA). Also examined were the factors that might influence templating accuracy (gender, surgeon experience, obesity, etc.).Materials and methodsThe study was retrospective and conducted in a specialized ENDOCERT arthroplasty center. Digital templating was done with the MediCAD software. If the planned and implanted TKA components (both femur and tibia) were the same size, the match was classified "exact." A deviation of +/- one size (at the femur or tibia or both) was classified "accurate." A deviation of +/- two or more sizes (at the femur or tibia or both) was classified "inaccurate." Obesity, gender, implant type and surgeon experience were investigated for potential influence on templating accuracy. Chi-square tests and Cohen's weighted kappa test were used for statistical analysis.ResultsA total of 482 cases [33.6% male, 66.4% female, age 69 +/- 11, body mass index (BMI) 30.3 +/- 5.8] were included. When the femur and tibia were taken together, exact size match was observed in 34% (95% CI 29.9-38.3%) of cases, accurate size match in 57.5% (95% CI 53-61.8%) and inaccurate size match in 8.5% (95% CI 6.3-11.2%). Inaccurate size match prolonged operative time (p = 0.028). Regarding the factors potentially influencing templating accuracy, only gender had a significant influence, with templating being more accurate in men (p = 0.004). BMI had no influence on accuracy (p = 0.87). No effect on accuracy was observed for implant type and surgeon experience.ConclusionsThe accuracy of 2D size templating in TKA is low, even in a specialized ENDOCERT arthroplasty center. The study findings challenge the usefulness of preoperative 2D size templating and highlight the importance of more reliable templating methods.
引用
收藏
页码:4705 / 4711
页数:7
相关论文
共 50 条
  • [21] Validating a Novel 2D to 3D Knee Reconstruction Method on Preoperative Total Knee Arthroplasty Patient Anatomies
    Factor, Shai
    Gurel, Ron
    Dan, Dor
    Benkovich, Guy
    Sagi, Amit
    Abialevich, Artsiom
    Benkovich, Vadim
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (05)
  • [22] Prediction of Total Knee Arthroplasty Sizes with Demographics, including Hand and Foot Sizes
    Chan, Vincent W. K.
    Chan, Ping Keung
    Fu, Henry
    Cheung, Man Hong
    Cheung, Amy
    Tang, Thomas C. M.
    Chiu, Kwong Yuen
    JOURNAL OF KNEE SURGERY, 2024, 37 (08) : 602 - 606
  • [23] Evaluation and validation of 2D biomechanical models of the knee for radiograph-based preoperative planning in total knee arthroplasty
    Asseln, Malte
    Eschweiler, Jorg
    Trepczynski, Adam
    Damm, Philipp
    Radermacher, Klaus
    PLOS ONE, 2020, 15 (01):
  • [24] A Comparison of Acetate vs Digital Templating for Preoperative Planning of Total Hip Arthroplasty
    Iorio, Richard
    Siegel, Jodi
    Specht, Lawrence M.
    Tilzey, John F.
    Hartman, Audrey
    Healy, William L.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (02): : 175 - 179
  • [25] Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty
    Kosashvili, Yona
    Shasha, Nadav
    Olschewski, Eli
    Safir, Oleg
    White, Larry
    Gross, Allan
    Backstein, David
    CANADIAN JOURNAL OF SURGERY, 2009, 52 (01) : 6 - 11
  • [26] Digital vs conventional templating techniques in preoperative planning for total hip arthroplasty
    White, LM
    Couch, GG
    Backstein, D
    Shasha, N
    Salonen, DC
    Gross, AE
    RADIOLOGY, 2001, 221 : 236 - 237
  • [27] Assessment of a new digital templating system in preoperative planning for total hip arthroplasty
    Chong, KB
    Cho, SW
    Choi, SW
    Park, SC
    Won, YY
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1296 - 1296
  • [28] Acetate templating on calibrated standing digital radiograph improves accuracy of preoperative templating for total hip arthroplasty
    Wang, Q.
    Xiao, J.
    Zhu, L.
    Zhao, X.
    Liu, Z.
    Wang, J.
    Qin, Y.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (03) : 341 - 347
  • [29] Algorithm based automatic templating is less accurate than manual digital templating in total knee arthroplasty
    Seaver, Thomas
    McAlpine, Kenneth
    Garcia, Enrique
    Niu, Ruijia
    Smith, Eric L.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (07) : 1472 - 1476
  • [30] Reliable prediction of implant size and axial alignment in AI-based 3D preoperative planning for total knee arthroplasty
    Lan, Qing
    Li, Shulin
    Zhang, Jiahao
    Guo, Huiling
    Yan, Laipeng
    Tang, Faqiang
    SCIENTIFIC REPORTS, 2024, 14 (01):