Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty

被引:5
|
作者
Riechelmann, Felix [1 ]
Lettner, H. [2 ]
Mayr, R. [1 ]
Tandogan, R. [3 ,4 ]
Dammerer, D. [5 ]
Liebensteiner, M. [1 ]
机构
[1] Med Univ Innsbruck, Dept Orthopaed & Traumatol, Anichstr 35, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Anichstr 35, A-6020 Innsbruck, Austria
[3] Ortoklinik, Ankara, Turkiye
[4] Halic Univ, Dept Orthopaed & Traumatol, Istanbul, Turkiye
[5] Univ Hosp Krems, Krems, Austria
关键词
Total knee arthroplasty; Digital templating; Accuracy; EndoCert; Operative time; Storage cost; REPLACEMENT;
D O I
10.1007/s00402-023-04772-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTo analyze the match between preoperatively determined implant size (2D templating) and intraoperatively used implant size in total knee arthroplasty (TKA). Also examined were the factors that might influence templating accuracy (gender, surgeon experience, obesity, etc.).Materials and methodsThe study was retrospective and conducted in a specialized ENDOCERT arthroplasty center. Digital templating was done with the MediCAD software. If the planned and implanted TKA components (both femur and tibia) were the same size, the match was classified "exact." A deviation of +/- one size (at the femur or tibia or both) was classified "accurate." A deviation of +/- two or more sizes (at the femur or tibia or both) was classified "inaccurate." Obesity, gender, implant type and surgeon experience were investigated for potential influence on templating accuracy. Chi-square tests and Cohen's weighted kappa test were used for statistical analysis.ResultsA total of 482 cases [33.6% male, 66.4% female, age 69 +/- 11, body mass index (BMI) 30.3 +/- 5.8] were included. When the femur and tibia were taken together, exact size match was observed in 34% (95% CI 29.9-38.3%) of cases, accurate size match in 57.5% (95% CI 53-61.8%) and inaccurate size match in 8.5% (95% CI 6.3-11.2%). Inaccurate size match prolonged operative time (p = 0.028). Regarding the factors potentially influencing templating accuracy, only gender had a significant influence, with templating being more accurate in men (p = 0.004). BMI had no influence on accuracy (p = 0.87). No effect on accuracy was observed for implant type and surgeon experience.ConclusionsThe accuracy of 2D size templating in TKA is low, even in a specialized ENDOCERT arthroplasty center. The study findings challenge the usefulness of preoperative 2D size templating and highlight the importance of more reliable templating methods.
引用
收藏
页码:4705 / 4711
页数:7
相关论文
共 50 条
  • [1] Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty
    Felix Riechelmann
    H. Lettner
    R. Mayr
    R. Tandogan
    D. Dammerer
    M. Liebensteiner
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 4705 - 4711
  • [2] Comparison of analog 2D and digital 3D preoperative templating for predicting implant size in total knee arthroplasty
    Kobayashi, Atsushi
    Ishii, Yoshinori
    Takeda, Mitsuhiro
    Noguchi, Hideo
    Higuchi, Hiroshi
    Toyabe, Sinichi
    COMPUTER AIDED SURGERY, 2012, 17 (02) : 96 - 101
  • [3] The accuracy of preoperative implant size prediction achieved by digital templating in total knee arthroplasty is not affected by the quality of lateral knee radiographs
    Pichler, Lorenz
    Klein, Leonhard
    Perka, Carsten F.
    Gwinner, Clemens
    El Kayali, Moses K. D.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [4] Comparison of digital and plain radiography preoperative templating in total knee arthroplasty
    J. Lewis
    M. Hossain
    A. Mustafa
    A. Sinha
    European Journal of Orthopaedic Surgery & Traumatology, 2008, 18 : 357 - 360
  • [5] Comparison of digital and plain radiography preoperative templating in total knee arthroplasty
    Lewis, J.
    Hossain, M.
    Mustafa, A.
    Sinha, A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2008, 18 (05): : 357 - 360
  • [6] 2D versus 3D templating in total knee arthroplasty
    Ettinger, Max
    Claassen, Leif
    Paes, Peter
    Calliess, Tilman
    KNEE, 2016, 23 (01): : 149 - 151
  • [7] Precision of preoperative digital templating in total hip arthroplasty
    Efe, Turgay
    El Zayat, Bilal Farouk
    Heyse, Thomas J.
    Timmesfeld, Nina
    Fuchs-Winkelmann, Susanne
    Schmitt, Jan
    ACTA ORTHOPAEDICA BELGICA, 2011, 77 (05): : 616 - 621
  • [8] A comparison of acetate and digital templating for total knee arthroplasty
    Specht, Lawrence M.
    Levitz, Seth
    Healy, William L.
    Tilzey, John F.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (464) : 179 - 183
  • [9] Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty
    Hernandez-Vaquero, Daniel
    Abat, Ferran
    Sarasquete, Juan
    Carlos Monllau, Juan
    WORLD JOURNAL OF ORTHOPEDICS, 2013, 4 (04): : 287 - 290
  • [10] Accuracy of Preoperative 3D vs 2D Digital Templating for Cementless Total Hip Arthroplasty Using a Direct Anterior Approach
    Aubert, Thomas
    Galanzino, Giacomo
    Gerard, Philippe
    Le Strat, Vincent
    Rigoulot, Guillaume
    Lhotellier, Luc
    ARTHROPLASTY TODAY, 2023, 24