Flexural performance of steel fiber reinforced concrete filled stainless steel tubular trusses

被引:4
|
作者
Kong, Wenyuan [1 ]
Zhou, Wenbo [2 ]
Chen, Libo [1 ]
Liao, Qinglong [3 ]
Zhu, Yao [1 ]
Chen, Yu [1 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 350116, Peoples R China
[2] Dongfang Elect Chengdu Engn & Consulting Co Ltd, Chengdu 610036, Peoples R China
[3] Zhongmei Engn Grp Ltd, Nanchang 330000, Peoples R China
基金
中国国家自然科学基金;
关键词
Concrete-filled steel tubular truss; Steel fiber reinforced concrete; Stainless steel tubular; Flexural performance; Ultimate bearing capacity; Overall deflection; ANALYTICAL BEHAVIOR; STUB COLUMNS; BRACE TRUSS; CFST CHORD; STRENGTH;
D O I
10.1016/j.compstruct.2022.116266
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The stainless steel tubular truss is known for dealing with corrosion problem of tubular truss, and mechanical properties of tubular truss can be improved ulteriorly by filling concrete to effectively avoid local buckling of steel tubular. To study the influence of the filling position of steel fiber reinforced concrete (SFRC) on flexural behavior of stainless steel tubular truss, four-point bending tests were carried out on four specimens. The specimens consist of three SFRC-filled stainless steel tubular trusses and a hollow section stainless steel tubular truss as control group. The experimental results show that filling the chord with SFRC can significantly improve the bearing capacity of the stainless steel tubular truss. At the same time, the internal mechanism of SFRC improving the bearing capacity of the structure is analyzed from the perspectives of failure mode, overall deformation characteristics and strain development of material. The effects of several different SFRC filling methods on improving the mechanical performance of specimens were compared. Finally, the finite element method is used to analyze the tested specimens. The accuracy of the proposed finite element modeling is proved, and the optimal filling method to make full use of the material property of SFRC is obtained through stress analysis.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Experimental and Theoretical Studies on Flexural Performance of Stainless Steel Reinforced Concrete Beams
    Li, Qingfu
    Guo, Wei
    Liu, Chenhui
    Kuang, Yihang
    Geng, Huitao
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [32] Influence of load condition on flexural properties and shear properties of steel tubular columns filled with steel-reinforced concrete
    Guan, Ping
    Chen, Lanxiang
    Progress in Industrial and Civil Engineering III, Pt 1, 2014, 638-640 : 127 - 131
  • [33] Flexural performance of round-ended concrete-filled steel tubular specimens
    Guo, Jun-Tao
    Wang, Zhi-Bin
    Tan, Ee Loon
    Gao, Yang-Hong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 215
  • [34] An Experimental Investigation On Flexural Behaviour Of Stainless Steel Fiber Reinforced Concrete Beam Elements
    Prasath, P.
    Silambarasan, D.
    2013 INTERNATIONAL CONFERENCE ON CURRENT TRENDS IN ENGINEERING AND TECHNOLOGY (ICCTET), 2013, : 146 - 151
  • [35] Flexural strength assessment of steel fiber reinforced concrete
    Lok, TS
    Xiao, JR
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 1999, 11 (03) : 188 - 196
  • [36] Flexural behavior of steel fiber reinforced concrete - Discussion
    Maalej, M
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 1999, 11 (02) : 179 - 180
  • [37] FLEXURAL PROPERTIES OF STEEL FIBER REINFORCED-CONCRETE
    SWAMY, RN
    ALNOORI, K
    CONCRETE, 1975, 9 (06): : 30 - 31
  • [38] Properties of flexural fatigue of steel fiber reinforced concrete
    Mizukoshi, Mutsumi
    Shimauchi, Hirotoshi
    Kaguma, Hirofumi
    Matsui, Shigeyuki
    Transactions of the Japan Concrete Institute, 1994, 16 : 311 - 316
  • [39] Flexural And Compressional Behavior Of Steel Fiber Reinforced Concrete
    Sivapriya, S., V
    Ridhuvaran, S.
    Karthick, V
    Gopikrishna, R.
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2018, 9 (06): : 405 - 412
  • [40] FLEXURAL STRENGTH OF STEEL FIBER REINFORCED-CONCRETE
    SWAMY, RN
    MANGAT, PS
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1974, 57 (DEC): : 701 - 707