Closed-Loop Insulin Delivery Systems for People with Type 1 Diabetes and Chronic Very Poor Metabolic Control: It Works and Is Safe!

被引:2
|
作者
Deepchand, Sonia [1 ]
Balla, Vanessa [1 ]
Eroukhmanoff, Juliette [1 ]
Sall, Khadijatou Ly [1 ]
Romain, Benedicte [1 ]
Lejeune, Marie [1 ]
Penfornis, Alfred [1 ,2 ]
Amadou, Coralie [1 ,2 ,3 ]
机构
[1] Sud Francilien Hosp, Diabet Dept, Corbeil Essonnes, France
[2] Paris Saclay Univ, Med Sch, Paris, France
[3] Sud Francilien Hosp, Diabet Dept, F-91190 Corbeil Essonnes, France
关键词
Closed-loop systems; Continuous glucose monitoring; Type; 1; diabetes; Poor metabolic control; GLYCEMIC CONTROL; RETINOPATHY;
D O I
10.1089/dia.2023.0379
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the percentage of patients with type 1 diabetes (T1D) and very poor metabolic control who would agree to be treated with a hybrid closed-loop (HCL) insulin delivery system, and to assess metabolic improvement and safety. In a single center, we identified all patients aged >18 years with hemoglobin A1c (HbA1c) >11% (97 mmol/mol) before HCL treatment. We collected metabolic control and safety data up to 1 year post-HCL in those who accepted HCL after it was proposed to them. We identified 65 patients eligible for the study, 32 (50%) already used, or accepted to start using HCL. Patients were aged 18-49 years; mean(+/- standard deviation) baseline HbA1c was 12.5(+/- 1.8)% (113 +/- 20 mmol/mol). After 1 year, 25 patients (78%) were still using HCL and their mean HbA1c decreased to 9.4(+/- 1.9)% (79 mmol/mol) (P < 0.001). The rate of acute metabolic events was similar during the year of follow-up to the rate in the 3 years before HCL initiation. HCL systems should be considered in patients with T1D and very poor metabolic control.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 50 条
  • [31] Impact of closed-loop systems in metabolic control and quality of life in pediatric patients with type 1 diabetes
    Itza Martin, N.
    Arias Lozano, C.
    Collar Serecigni, P.
    Ibarra Solis, S.
    Carcavilla Urqui, A.
    Gonzalez Casado, I.
    HORMONE RESEARCH IN PAEDIATRICS, 2024, 97 : 238 - 238
  • [32] Comparative Effectiveness of Hybrid Closed-Loop Automated Insulin Delivery Systems Among Patients with Type 1 Diabetes
    Folk, Sara
    Zappe, Janet
    Wyne, Kathleen
    Dungan, Kathleen M.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024,
  • [33] Metabolic modelling and the closed-loop insulin delivery problem
    Steil, Garry
    Rebrin, Kerstin
    Mastrototaro, John J.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2006, 74 : S183 - S186
  • [34] Randomized Trial of Closed-Loop Control in Very Young Children with Type 1 Diabetes
    Ware, J.
    Allen, J. M.
    Boughton, C. K.
    Wilinska, M. E.
    Hartnell, S.
    Thankamony, A.
    de Beaufort, C.
    Schierloh, U.
    Froehlich-Reiterer, E.
    Mader, J. K.
    Kapellen, T. M.
    Rami-Merhar, B.
    Tauschmann, M.
    Nagl, K.
    Hofer, S. E.
    Campbell, F. M.
    Yong, J.
    Hood, K. K.
    Lawton, J.
    Roze, S.
    Sibayan, J.
    Bocchino, L. E.
    Kollman, C.
    Hovorka, R.
    NEW ENGLAND JOURNAL OF MEDICINE, 2022, 386 (03): : 209 - 219
  • [35] Evaluation of a portable ambulatory prototype for automated overnight closed-loop insulin delivery in young people with type 1 diabetes
    Elleri, Daniela
    Allen, Janet M.
    Biagioni, Martina
    Kumareswaran, Kavita
    Leelarathna, Lalantha
    Caldwell, Karen
    Nodale, Marianna
    Wilinska, Malgorzata E.
    Acerini, Carlo L.
    Dunger, David B.
    Hovorka, Roman
    PEDIATRIC DIABETES, 2012, 13 (06) : 449 - 453
  • [36] Strengths and Challenges of Closed-Loop Insulin Delivery During Exercise in People With Type 1 Diabetes: Potential Future Directions
    Paldus, Barbora
    Morrison, Dale
    Lee, Melissa
    Zaharieva, Dessi P.
    Riddell, Michael C.
    O'Neal, David N.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (04): : 1077 - 1084
  • [37] Pharmacokinetics of insulin lispro in type 2 diabetes during closed-loop insulin delivery
    Ruan, Yue
    Thabit, Hood
    Kumareswaran, Kavita
    Hovorka, Roman
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 117 (02) : 298 - 307
  • [38] Hybrid Closed-Loop Control Is Safe and Effective for People with Type 1 Diabetes Who Are at Moderate to High Risk for Hypoglycemia
    Anderson, Stacey M.
    Buckingham, Bruce A.
    Breton, Marc D.
    Robic, Jessica L.
    Barnett, Charlotte L.
    Wakeman, Christian A.
    Oliveri, Mary C.
    Brown, Sue A.
    Ly, Trang T.
    Clinton, Paula K.
    Hsu, Liana J.
    Kingman, Ryan S.
    Norlander, Lisa M.
    Loebner, Sarah E.
    Reuschel-DiVirglio, Suzette
    Kovatchev, Boris P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (06) : 356 - 363
  • [39] Insulin pump therapy in youth with type 1 diabetes: toward closed-loop systems
    Tauschmann, Martin
    Hovorka, Roman
    EXPERT OPINION ON DRUG DELIVERY, 2014, 11 (06) : 943 - 955
  • [40] SLEEP IN CAREGIVERS OF VERY YOUNG CHILDREN WITH TYPE 1 DIABETES USING A SENSOR AUGMENTED PUMP OR CLOSED-LOOP INSULIN DELIVERY
    Madrid-Valero, J.
    Gregory, A.
    Ware, J.
    Allen, J.
    Boughton, C.
    Hartnell, S.
    Wilinska, M.
    Thankamony, A.
    De Beaufort, C.
    Schierloh, U.
    Campbell, F.
    Sibayan, J.
    Bocchino, L.
    Kollman, C.
    Hovorka, R.