Dynamic thermal performance and energy-saving potential analysis of a modular pipe-embedded building envelope integrated with thermal diffusive materials

被引:6
|
作者
Yang, Yang [1 ,3 ]
Chen, Sarula [2 ,3 ]
机构
[1] Hefei Univ Technol, Coll Architecture & Art, Hefei 230601, Peoples R China
[2] Anhui Jianzhu Univ, Coll Architecture & Urban Planning, Hefei 230601, Peoples R China
[3] State Key Lab Green Bldg Western China, Xian 710055, Peoples R China
基金
安徽省自然科学基金; 中国国家自然科学基金;
关键词
building energy efficiency; pipe-embedded building envelope; thermal diffusive material; thermal characteristics; numerical simulation; HEAT-TRANSFER; WATER; VALIDATION; FACADE; WALL;
D O I
10.1007/s12273-023-1039-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the context of racing to carbon neutrality, the pipe-embedded building system makes the opaque envelopes gradually regarded as the multi-functional element, which also provides an opportunity for thermal insulation solutions to transform from high to zero-carbon attributes. Based on the re-examination of the heat transfer process of conventional pipe-embedded radiant (CPR) walls, the modular pipe-embedded radiant (MPR) wall integrated with thermal diffusive materials is proposed to enhance the heat transfer capacity of CPR walls in the direction parallel to the wall surface, thereby forming a more stable and continuous invisible thermal barrier layer inside the opaque envelopes. A comprehensive thermal and energy-saving analysis study regarding the influence mechanism of several key factors of MPR walls, e.g., the inclination angle of the filler cavity (theta-value), geometry size of the filler cavity (a:b-value) and thermal conductivity of the filler (lambda f-value), is conducted based on a validated numerical model. Results show that the dynamic thermal behaviors of MPR walls can be significantly improved due to that the radial thermal resistance in the filler cavity of MPR walls can be reduced by 50%, while the maximum extra exterior surface heat loss caused by the optimization measures is only 2.1%. Besides, a better technical effect can be achieved by setting the major axis of the filler cavity towards the room side, where the interior surface heat load/total injected heat first decreases/increases and then increases/decreases with the increase of the theta-value. In particular, the MPR wall with theta L = 60 degrees can obtain the best performance when other conditions remain the same. Moreover, the performance indicators of MPR walls can be further improved with the increase of the cavity size (a:b-value), while showing a trend of rapid improvement in the lambda f-value range of 2-5 lambda C and slow improvement increase in the lambda f-value range of 5-12 lambda C. In addition, the improvement effect brought by optimizing the theta-value is more obvious as the a:b-value or lambda f-value increases.
引用
收藏
页码:2285 / 2305
页数:21
相关论文
共 50 条
  • [21] A simplified method for the thermal performance analysis of double-layer pipe-embedded external wall
    Zhao, Yaxin
    Zha, Fuhai
    Li, Xianting
    JOURNAL OF BUILDING ENGINEERING, 2023, 80
  • [22] Quantitative evaluation of thermal performance and energy saving potential of the building integrated with PCM in a subarctic climate
    Kenzhekhanov, Sultan
    Memon, Shazim Ali
    Adilkhanova, Indira
    ENERGY, 2020, 192
  • [23] Building envelope regulations on thermal comfort in glass facade buildings and energy-saving potential for PMV-based comfort control
    Hwang, Ruey-Lung
    Shu, Shiu-Ya
    BUILDING AND ENVIRONMENT, 2011, 46 (04) : 824 - 834
  • [24] Environmental thermal performance of prefabricated buildings based on building wall energy-saving technology
    Zou D.
    Sun C.
    International Journal of Sustainable Development and Planning, 2020, 15 (06): : 965 - 969
  • [25] Study on the construction of the database of energy-saving building wall's thermal performance in Hangzhou
    Wu, Fang
    Zhu, Jiang
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 943 - 948
  • [26] A comprehensive study on transient thermal behaviors and performances of the modular pipe-embedded energy wall system under intermittent operation conditions
    Yang, Yang
    Chen, Sarula
    Zhang, Jiqiang
    ENERGY, 2023, 280
  • [27] Automated Analysis of the Energy-Saving Potential in a Thermal Engineering System for Phosphorus Production
    S. V. Panchenko
    Theoretical Foundations of Chemical Engineering, 2004, 38 : 538 - 544
  • [28] Automated analysis of the energy-saving potential in a thermal engineering system for phosphorus production
    Panchenko, S.V.
    Teoreticheskie Osnovy Khimicheskoi Tekhnologii, 2004, 38 (05): : 570 - 576
  • [29] Numerical study on thermal comfort and energy-saving potential of a prefabricated temporary house integrated with composite phase change materials
    Ye, Rongda
    Wang, Jun
    Jiang, Hong
    Xie, Ning
    ENERGY AND BUILDINGS, 2022, 268
  • [30] Automated analysis of the energy-saving potential in a thermal engineering system for phosphorus production
    Panchenko, SV
    THEORETICAL FOUNDATIONS OF CHEMICAL ENGINEERING, 2004, 38 (05) : 538 - 544