A novel potentiometric approach for the sensitive detection of cadmium in real samples using modified carbon paste electrodes

被引:0
|
作者
EL-Sanafery, Safa S. S. [1 ]
Ibrahim, Mahmoud W. W. [2 ]
Abbas, Ashraf A. A. [2 ]
Mohamed, Gehad G. G. [2 ,3 ]
机构
[1] Menoufia Univ, Fac Sci, Chem Dept, Shibin Al Kawm 32511, Egypt
[2] Cairo Univ, Fac Sci, Chem Dept, Giza 12613, Egypt
[3] Egypt Japan Univ Sci & Technol, Basic & Appl Sci Inst, Nanosci Dept, Alexandria 21934, Egypt
关键词
carbon paste electrode; inductively coupled plasma; ionophore; plasticizer; potentiometric; SOLID-PHASE EXTRACTION; ABSORPTION SPECTROMETRIC DETERMINATION; CLOUD POINT EXTRACTION; TRACE CADMIUM; SPECTROPHOTOMETRIC DETERMINATION; LIQUID EXTRACTION; AQUEOUS-SOLUTION; WATER SAMPLES; LEAD; PRECONCENTRATION;
D O I
10.1002/elan.202300034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The goal of this study was to demonstrate a novel potentiometric technique for the measurement of Cd(II) ion. A new ionophore called [5 '-(ethane-1,2-diylbis(sulfanediyl))bis(3-phenyl-4H-1,2,4-triazol-4-amine) (ESPTA)] was prepared and used as an electroactive material in the fabrication of new carbon paste electrode (CPE) for the quantification of Cd(II) ion. The paste was prepared by mixing ESPTA, graphite, graphene, and TCP or o-NPOE as a plasticizer in different weight percent ratios. The developed electrodes I, II, III, and IV showed divalent Nernstian response of 29.80 +/- 0.05, 29.80 +/- 0.08, 29.86 +/- +/- 0.04 and 29.75 +/- 0.33 mV decade 1 over the concentration ranges of 1.0 x 10(-5)-1.0 x 10(-1), 1.0 x 10(-8)-1.0 x 10(-1), 1.0 x 10(-6)-1.0 x 10(-1) and 1.0 x 10(-7)-1.0 x 10(-1) molL(-1) with percentage of (2.65 ESPTA: 66.32 graphite: 31.03 TCP), (2.65 ESPTA: 13.27 graphite : 53.05 graphene : 31.03 TCP), (2.75 ESPTA: 68.68 graphite: 28.57 o-NPOE) and (2.75 ESPTA: 13.74 graphite : 54.94 graphene : 28.57 o-NPOE), for electrodes I, II, III, and IV, respectively. In order to improve the performance characteristics of electrodes I, II, III, and IV, response time, the effect of temperature, and pH were examined. The electrodes showed high selectivity for Cd(II) over different mono-, di- or trivalent cations. These modified electrodes were applied for the determination of the concentration of Cd(II) in different real samples like Nido Milk, juice extractions and tap water samples with high percentage recovery. The F- and t-test values showed that there is no statistically significant difference between the results obtained and those from the stated method of inductively coupled plasma. Low standard and relative standard deviation values, good percentage recovery, and modest detection and quantification limitations were all displayed by the electrodes. The outcomes showed the potentiometric method's effectiveness in detecting Cd(II) in actual samples and its potential for use in routine analysis.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Potentiometric Determination of Maprotiline Hydrochloride in Pharmaceutical and Biological Matrices Using a Novel Modified Carbon Paste Electrode
    Radic, Josip
    Perovic, Dorotea
    Gricar, Ema
    Kolar, Mitja
    SENSORS, 2022, 22 (23)
  • [32] Determination of Microgram Amounts of Copper in Real Samples Using New Modified Carbon Paste Electrode
    Youssef, Ahmed Fahmy A.
    Issa, Yousry M.
    Shehab, Ola R.
    Sherief, Heba
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (06): : 4752 - 4769
  • [33] Fabrication of Carbon Paste Electrodes Modified with Multi-walled Carbon Nanotubes for the Potentiometric Determination of Chromium(III)
    Fakhrabad, Azam Hosseini
    Khoshnood, Razieh Sanavi
    Ebrahimi, Mahmoud
    Abedi, Mohammad Reza
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (07) : 951 - 957
  • [34] A sensitive amperometric detection of neurotransmitter acetylcholine using carbon dot-modified carbon paste electrode
    Bodur, Onur Can
    Dinc, Saliha
    Ozmen, Mustafa
    Arslan, Fatma
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2021, 68 (01) : 20 - 29
  • [35] Fabrication of Carbon Paste Electrodes Modified with Multi-walled Carbon Nanotubes for the Potentiometric Determination of Chromium(III)
    Razieh Sanavi Azam Hosseini Fakhrabad
    Mahmoud Khoshnood
    Mohammad Reza Ebrahimi
    Journal of Analytical Chemistry, 2020, 75 : 951 - 957
  • [36] Detection of vitamin b1 (thiamine) using modified carbon paste electrodes with polypyrrole
    Muppariqoh, N. M.
    Wahyuni, W. T.
    Putra, B. R.
    3RD INTERNATIONAL SEMINAR ON SCIENCES SCIENCES ON PRECISION AND SUSTAINABLE AGRICULTURE (ISS-2016), 2017, 58
  • [37] A novel electrochemical ion imprinting sensor modified with carbon nanocomposites and its high selectivity for cadmium ion detection in real samples
    Zhang, Yi
    Xu, Wanzhen
    Liu, Yanmeng
    Huang, Weihong
    Yang, Wenming
    POLYMER INTERNATIONAL, 2023, 72 (12) : 1096 - 1103
  • [38] Detection of Allura Red in Food Samples Using Carbon Paste Modified with Lanthanum and Titanium Oxides
    Vargas-Varela, Anthony
    Cardenas-Riojas, Andy A.
    Nagles, Edgar
    Hurtado, John
    CHEMISTRYSELECT, 2023, 8 (05):
  • [39] Potentiometric determination of urinary iodide using a nanoparticle modified carbon paste electrode
    Wang, Ning
    Wang, Fenfen
    Liao, Yeting
    Liu, Huanhuan
    Li, Yijun
    He, Xiwen
    ANALYTICAL METHODS, 2017, 9 (21) : 3159 - 3165
  • [40] Modified carbon paste electrode with ionic liquid and SiO2 nanoparticles for potentiometric determination of Copper(II) ions in real samples
    SoheilaSaghiri
    Ebrahimi, Mahmoud
    Beyramabadi, Safar Ali
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2016, 5 (08): : 326 - 331