A novel potentiometric approach for the sensitive detection of cadmium in real samples using modified carbon paste electrodes

被引:0
|
作者
EL-Sanafery, Safa S. S. [1 ]
Ibrahim, Mahmoud W. W. [2 ]
Abbas, Ashraf A. A. [2 ]
Mohamed, Gehad G. G. [2 ,3 ]
机构
[1] Menoufia Univ, Fac Sci, Chem Dept, Shibin Al Kawm 32511, Egypt
[2] Cairo Univ, Fac Sci, Chem Dept, Giza 12613, Egypt
[3] Egypt Japan Univ Sci & Technol, Basic & Appl Sci Inst, Nanosci Dept, Alexandria 21934, Egypt
关键词
carbon paste electrode; inductively coupled plasma; ionophore; plasticizer; potentiometric; SOLID-PHASE EXTRACTION; ABSORPTION SPECTROMETRIC DETERMINATION; CLOUD POINT EXTRACTION; TRACE CADMIUM; SPECTROPHOTOMETRIC DETERMINATION; LIQUID EXTRACTION; AQUEOUS-SOLUTION; WATER SAMPLES; LEAD; PRECONCENTRATION;
D O I
10.1002/elan.202300034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The goal of this study was to demonstrate a novel potentiometric technique for the measurement of Cd(II) ion. A new ionophore called [5 '-(ethane-1,2-diylbis(sulfanediyl))bis(3-phenyl-4H-1,2,4-triazol-4-amine) (ESPTA)] was prepared and used as an electroactive material in the fabrication of new carbon paste electrode (CPE) for the quantification of Cd(II) ion. The paste was prepared by mixing ESPTA, graphite, graphene, and TCP or o-NPOE as a plasticizer in different weight percent ratios. The developed electrodes I, II, III, and IV showed divalent Nernstian response of 29.80 +/- 0.05, 29.80 +/- 0.08, 29.86 +/- +/- 0.04 and 29.75 +/- 0.33 mV decade 1 over the concentration ranges of 1.0 x 10(-5)-1.0 x 10(-1), 1.0 x 10(-8)-1.0 x 10(-1), 1.0 x 10(-6)-1.0 x 10(-1) and 1.0 x 10(-7)-1.0 x 10(-1) molL(-1) with percentage of (2.65 ESPTA: 66.32 graphite: 31.03 TCP), (2.65 ESPTA: 13.27 graphite : 53.05 graphene : 31.03 TCP), (2.75 ESPTA: 68.68 graphite: 28.57 o-NPOE) and (2.75 ESPTA: 13.74 graphite : 54.94 graphene : 28.57 o-NPOE), for electrodes I, II, III, and IV, respectively. In order to improve the performance characteristics of electrodes I, II, III, and IV, response time, the effect of temperature, and pH were examined. The electrodes showed high selectivity for Cd(II) over different mono-, di- or trivalent cations. These modified electrodes were applied for the determination of the concentration of Cd(II) in different real samples like Nido Milk, juice extractions and tap water samples with high percentage recovery. The F- and t-test values showed that there is no statistically significant difference between the results obtained and those from the stated method of inductively coupled plasma. Low standard and relative standard deviation values, good percentage recovery, and modest detection and quantification limitations were all displayed by the electrodes. The outcomes showed the potentiometric method's effectiveness in detecting Cd(II) in actual samples and its potential for use in routine analysis.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Potentiometric Determination of Oxymetazoline Hydrochloride Using Modified Carbon Paste Electrodes
    Issa, Yousry M.
    Khalil, Mohamed M.
    Zayed, Sayed I. M.
    Mustafa, Naglaa
    PORTUGALIAE ELECTROCHIMICA ACTA, 2021, 39 (05) : 381 - 392
  • [2] Lead determination by potentiometric method using a new modified carbon paste electrode in real food samples
    Hussein, Khaled M.
    Omar, M. M.
    Mohamed, Gehad G.
    EL-Sanafery, Safa S.
    MICROCHEMICAL JOURNAL, 2025, 208
  • [3] Flow Injection Potentiometric Determination of Pancuronium Bromide in Pharmaceutical Preparation and Urine Samples Using Modified Carbon Paste Electrodes
    Zayed, Sayed Imam Mohamed
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2011, 59 (02) : 254 - 259
  • [4] Flow Injection Potentiometric Determination of Terazosin Hydrochloride Using Modified Carbon Paste Electrodes
    Zayed, Sayed I. M.
    Khalil, Mohamed M.
    Issa, Yousry M.
    Khalefa, Huda R.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (05): : 2327 - 2340
  • [5] Determination of haloperidol drug in ampoules and in urine samples using a potentiometric modified carbon paste electrode
    Abu Shawish, Hazem M.
    Almonem, Khaled I. Abed
    Saadeh, Salman M.
    Al-Iham, Wael S.
    MEASUREMENT, 2016, 78 : 180 - 186
  • [6] Potentiometric determination of oxybutynin hydrochloride in pharmaceutical formulations at modified carbon paste electrodes
    Mostafa, Maysa R.
    Mohamed, Gehad G.
    Mohamed, Marwa E.
    Frag, Eman Y. Z.
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2020, 59 (03): : 324 - 332
  • [7] Selective and sensitive determination of Cd(II) ions in various samples using a novel modified carbon paste electrode
    Aglan, Refaat F.
    Named, Mostafa M.
    Saleh, Hosam M.
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2019, 10 (1)
  • [8] Selective and sensitive determination of Cd(II) ions in various samples using a novel modified carbon paste electrode
    Refaat F. Aglan
    Mostafa M. Hamed
    Hosam M. Saleh
    Journal of Analytical Science and Technology, 10
  • [9] A sensitive approach for the detection and analysis of indigo carmine using poly (Niacin) modified carbon paste sensor
    Madappa, Sharmila Battira
    Manjunatha, Jamballi Gangadarappa Gowda
    Aljuwayid, Ahmed Muteb
    Habila, Mohamed A.
    Sillanpaa, Mika
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2023, 17 (04) : 3962 - 3972
  • [10] A sensitive approach for the detection and analysis of indigo carmine using poly (Niacin) modified carbon paste sensor
    Sharmila Battira Madappa
    Jamballi Gangadarappa Gowda Manjunatha
    Ahmed Muteb Aljuwayid
    Mohamed A. Habila
    Mika Sillanpaa
    Journal of Food Measurement and Characterization, 2023, 17 : 3962 - 3972