Experimental study on fire characteristics in a double long-narrow confined space connected by multiple lateral doors

被引:4
|
作者
Peng, Min [1 ]
Wu, Zhenkun [1 ]
Zhou, Yun [1 ]
Ming, Yuyang [1 ]
Song, Chunxiao [1 ]
He, Kun [2 ]
Zhu, Guoqing [1 ]
机构
[1] China Univ Min & Technol, Sch Safety Engn, Xuzhou 221116, Jiangsu, Peoples R China
[2] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
关键词
Double long-narrow confined space; Smoke characteristic; Flame extension; Flame spillover phenomenon; TEMPERATURE DISTRIBUTION; SMOKE MOVEMENT; TUNNEL; PRESSURE; BENEATH;
D O I
10.1016/j.csite.2023.103404
中图分类号
O414.1 [热力学];
学科分类号
摘要
A series of experiments were carried out within a scaled-down, elongated, and narrow space featuring multiple lateral doors. These experiments aimed to thoroughly examine the fire characteristics both inside the enclosed compartment and within the connected tunnel, which were induced by the fire occurring in the compartment. It shows that the classic maximum temperature model obtained from a single confined space underestimates or overestimates the values in the carriage and tunnel, and the three-region plume law cannot effectively cover the temperature values inside the carriage, the prediction relations for the double confined space scenario are proposed. The rate of temperature decrease beneath the ceiling in the double long-narrow confined space is greater than in a single confined space, with a significantly reduced impact of HRR on the decay rate. The study also provides a segmented characterization of the influence of HRR on temperature attenuation. Additionally, distinct flame extension and spillover patterns are observed at different fire source locations. These include ceiling jet flame overflow primarily from the upper part of the lateral door and direct overflow from the entire door height. The study's findings offer valuable insights for fire assessment and control in complex confined rail systems.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Experimental investigation on extinguishing characteristics of liquid nitrogen in underground long and narrow space
    Li, Huaxiang
    Zhang, Guowei
    Jia, Boyan
    Zhu, Guoqing
    Guo, Dong
    Zhang, Peng
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 114
  • [32] Experimental study on the interaction between fire and water mist in long and narrow spaces
    Zhang, Peihong
    Tang, Xing
    Tian, Xiangliang
    Liu, Chang
    Zhong, Maohua
    APPLIED THERMAL ENGINEERING, 2016, 94 : 706 - 714
  • [33] Experimental study on the pulse water mist fire suppression system performance in a confined space
    Lun, P. Y.
    Zhang, Q.
    Li, X. K.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2020, 42 (05)
  • [34] Experimental study on the pulse water mist fire suppression system performance in a confined space
    P. Y. Lun
    Q. Zhang
    X. K. Li
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42
  • [35] An Experimental Investigation of the Influence of Flow and Pipe Diameter on the Fire Extinguishing Efficiency of Nitrogen Injection in a Narrow Confined Underground Space
    Zhang, Guowei
    Guo, Dong
    Li, Bin
    Zhang, Zhiwei
    Yuan, Diping
    FIRE-SWITZERLAND, 2022, 5 (06):
  • [36] Experimental study of double-panel confined masonry walls under lateral loading
    Belghiat, Choayb
    Messabhia, Ali
    Plassiard, Jean-Patrick
    Guenfoud, Mohamed
    Ple, Olivier
    Perrotin, Pascal
    JOURNAL OF BUILDING ENGINEERING, 2018, 20 : 531 - 543
  • [37] Experimental Study on Transmission Characteristics of Coal Dust Explosion in Confined Laneway Space
    Cheng Lei
    Jing Guoxun
    Yang Shuzhao
    Duan Zhenwei
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL. VIII, PTS A AND B, 2010, 8 : 1536 - 1540
  • [38] Experimental and Mechanism Study of Electrically Charged Water Mist for Controlling Kerosene Fire in a Confined Space
    Xu, Yong-liang
    Wang, Lan-yun
    Liang, Dong-lin
    Yu, Ming-gao
    Chu, Ting-xiang
    2013 INTERNATIONAL CONFERENCE ON PERFORMANCE-BASED FIRE AND FIRE PROTECTION ENGINEERING (ICPFFPE 2013), 2014, 71 : 246 - 252
  • [39] Numerical Study on the Influence of Ventilation on the Heat Flow of Cable Fire in Narrow-long Space
    Xiong, Yanyi
    Ma, Yiwei
    Shen, Bing
    Zhu, Kezhou
    Zhao, Huiping
    2020 5TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY AND ENVIRONMENTAL PROTECTION, 2020, 621
  • [40] An experimental study on fire characteristics of urban complex underground space based on BIM
    Cui, Jinrong
    Mei, Hao
    Sun, Haosen
    Ye, Jingqi
    Hu, Wei
    Xu, Yong
    CAAI TRANSACTIONS ON INTELLIGENCE TECHNOLOGY, 2023, 8 (04) : 1403 - 1414