Fault ride through constrained protection scheme for distribution networks with DFIG-based wind parks

被引:6
|
作者
Yoosefian, Davood [1 ]
Askarian-Abyaneh, Hossein [1 ]
Kheshti, Mostafa [2 ]
Li, Qi [3 ]
Terzija, Vladimir [4 ]
机构
[1] Amirkabir Univ Technol, Dept Elect Engn, Tehran, Iran
[2] Univ Warwick, Sch Engn, Intelligent Control & Smart Energy ICSE Res Grp, Coventry, England
[3] Chongqing Univ, Chong Qing Shi, Peoples R China
[4] Skolkovo Inst Sci & Technol Skoltech, Ctr Energy Sci & Technol CEST, Moscow, Russia
关键词
Communication link; Coordination; Fault ride through (FRT); Overcurrent relay; Wind turbine;
D O I
10.1016/j.epsr.2022.108973
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The main protection of distribution networks is based on overcurrent relays (OCRs). Due to the slow operation of these relays, some distributed generations (DGs), e.g. wind parks, may be unable to meet the fault ride through (FRT) requirements, which leads to unnecessary generation loss during faults. This paper proposes a new pro-tection scheme for distribution networks that considers the FRT requirements of DFIG-Based wind parks. This is achieved by considering both the protection coordination constraints and FRT requirements in a single protec-tion scheme. Considering the FRT requirements, the new method determines whether each overcurrent relay operates fast enough. If not, the proposed scheme determines a suitable solution for each relay to facilitate a faster operation. The proposed method is tested on the IEEE 33 bus test network and compared with conventional methods. Its superior impact on improving the FRT requirements and hence preventing unnecessary discon-nection of DFIG-Based wind parks during short circuit faults is demonstrated through simulation results, proving by this its applicability and efficacy.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Low Voltage Ride-Through Enhancement in DFIG-Based Wind Turbine
    Gatavi, Ehsan
    Hellany, Ali
    Nagrial, Mahmood
    Rizk, Jamal
    2016 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC), 2016,
  • [32] High-Order Sliding Mode Control for DFIG-Based Wind Turbine Fault Ride-Through
    Benbouzid, Mohamed
    Beltran, Brice
    Amirat, Yassine
    Yao, Gang
    Han, Jingang
    Mangel, Herve
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 7670 - 7674
  • [33] A Dynamic Multi-Cell FCL to Improve the Fault Ride through Capability of DFIG-Based Wind Farms
    Shafiee, M. R.
    Kartijkolaie, H. Shahbabaei
    Firouzi, M.
    Mobayen, S.
    Fekih, A.
    ENERGIES, 2020, 13 (22)
  • [34] Coordinated Control of SMES and DVR for Improving Fault Ride-Through Capability of DFIG-based Wind Turbine
    Bouaziz, Fatma
    Masmoudi, Abdelkarim
    Abdelkafi, Achraf
    Krichen, Lotfi
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2022, 12 (01): : 359 - 371
  • [35] Fault Ride Through Technique for DFIG-based Wind Turbines Under Grid Three-phase Faults
    Makolo, Peter
    Justo, Jackson J.
    Mwasilu, Francis
    Zamora, Ramon
    2018 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2018,
  • [36] Efficient fault-ride-through control strategy of DFIG-based wind turbines during the grid faults
    Mohammadi, J.
    Afsharnia, S.
    Vaez-Zadeh, S.
    ENERGY CONVERSION AND MANAGEMENT, 2014, 78 : 88 - 95
  • [37] Multi-agent system-assisted fault section location scheme for distribution networks with DFIG-based wind DGs
    Li, Xu
    Gui, Lin
    Chen, Jun
    Lu, Yuping
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 233
  • [38] Enhancing the fault ride through capability of DFIG-based wind energy system using saturated core fault current limiter
    Tripathi, Prashant Mani
    Sahoo, Subhendu Sekhar
    Chatterjee, Kalyan
    JOURNAL OF ENGINEERING-JOE, 2019, (18): : 4916 - 4921
  • [39] Study of fault ride-through for DFIG based wind turbines
    Bing, X
    Fox, B
    Flynn, D
    PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION, RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1 AND 2, 2004, : 411 - 416
  • [40] Evaluation of Fault Ride Through Capability Enhancement of DFIG-Based Wind Turbine with Bi-2212 Superconducting Fault Current Limiter
    Romphochai, Sillawat
    Hongesombut, Komsan
    2015 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2015,