DEMIST: A Deep-Learning-Based Detection-Task-Specific Denoising Approach for Myocardial Perfusion SPECT

被引:0
|
作者
Rahman, Md Ashequr [1 ]
Yu, Zitong [1 ]
Laforest, Richard [2 ]
Abbey, Craig K. [3 ]
Siegel, Barry A. [2 ]
Jha, Abhinav K. [1 ,2 ]
机构
[1] Washington Univ, Dept Biomed Engn, St. Louis, MO 63130 USA
[2] Washington Univ, Mallinckrodt Inst Radiol, St. Louis, MO 63130 USA
[3] Univ Calif Santa Barbara, Dept Psychol & Brain Sci, Santa Barbara, CA 93106 USA
关键词
Task analysis; Observers; Noise reduction; Single photon emission computed tomography; Vectors; Protocols; Image reconstruction; Detection; image denoising; myocardial perfusion imaging (MPI); objective task-based evaluation; single-photon emission computed tomography (SPECT); IMAGE QUALITY; OBSERVER PERFORMANCE; DEFECT DETECTION; SIGNAL-DETECTION; CARDIAC SPECT; NOISE; REGULARIZATION; OPTIMIZATION; SIMULATION;
D O I
10.1109/TRPMS.2024.3379215
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
There is an important need for methods to process myocardial perfusion imaging (MPI) single-photon emission computed tomography (SPECT) images acquired at lower-radiation dose and/or acquisition time such that the processed images improve observer performance on the clinical task of detecting perfusion defects compared to low-dose images. To address this need, we build upon concepts from model-observer theory and our understanding of the human visual system to propose a detection task-specific deep-learning-based approach for denoising MPI SPECT images (DEMIST). The approach, while performing denoising, is designed to preserve features that influence observer performance on detection tasks. We objectively evaluated DEMIST on the task of detecting perfusion defects using a retrospective study with anonymized clinical data in patients who underwent MPI studies across two scanners ( $N\,\,=$ 338). The evaluation was performed at low-dose levels of 6.25%, 12.5%, and 25% and using an anthropomorphic channelized Hotelling observer. Performance was quantified using area under the receiver operating characteristics curve (AUC). Images denoised with DEMIST yielded significantly higher AUC compared to corresponding low-dose images and images denoised with a commonly used task-agnostic deep learning-based denoising method. Similar results were observed with stratified analysis based on patient sex and defect type. Additionally, DEMIST improved visual fidelity of the low-dose images as quantified using root mean squared error and structural similarity index metric. A mathematical analysis revealed that DEMIST preserved features that assist in detection tasks while improving the noise properties, resulting in improved observer performance. The results provide strong evidence for further clinical evaluation of DEMIST to denoise low-count images in MPI SPECT.
引用
收藏
页码:439 / 450
页数:12
相关论文
共 50 条
  • [1] Frequency specific denoising for myocardial perfusion SPECT using deep learning
    Du, Yu
    Sun, Jingzhang
    Li, Chien-Ying
    Wu, Tung-Hsin
    Yang, Bang-Hung
    Mok, Greta
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [2] Observer-study-based evaluation of a taskspecific deep-learning-based denoising method for myocardial perfusion SPECT using clinical data
    Rahman, Md Ashequr
    Yu, Zitong
    Siegel, Barry
    Jha, Abhinav
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [3] Deep learning-based multi-frequency denoising for myocardial perfusion SPECT
    Du, Yu
    Sun, Jingzhang
    Li, Chien-Ying
    Yang, Bang-Hung
    Wu, Tung-Hsin
    Mok, Greta S. P.
    EJNMMI PHYSICS, 2024, 11 (01):
  • [4] Need for objective task-based evaluation of deep learning-based denoising methods: A study in the context of myocardial perfusion SPECT
    Yu, Zitong
    Rahman, Md Ashequr
    Laforest, Richard
    Schindler, Thomas H. H.
    Gropler, Robert J. J.
    Wahl, Richard L. L.
    Siegel, Barry A. A.
    Jha, Abhinav K. K.
    MEDICAL PHYSICS, 2023, 50 (07) : 4122 - 4137
  • [5] Investigating the limited performance of a deep-learning-based SPECT denoising approach: An observer-study-based characterization
    Yu, Zitong
    Rahman, Md Ashequr
    Jha, Abhinav K.
    MEDICAL IMAGING 2022: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2022, 12035
  • [6] Deep-Learning-Based Preprocessing for Quantitative Myocardial Perfusion MRI
    Scannell, Cian M.
    Veta, Mitko
    Villa, Adriana D. M.
    Sammut, Eva C.
    Lee, Jack
    Breeuwer, Marcel
    Chiribiri, Amedeo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (06) : 1689 - 1696
  • [7] Improving detection accuracy of perfusion defect in standard dose SPECT-myocardial perfusion imaging by deep-learning denoising
    Junchi Liu
    Yongyi Yang
    Miles N. Wernick
    P. Hendrik Pretorius
    Piotr J. Slomka
    Michael A. King
    Journal of Nuclear Cardiology, 2022, 29 : 2340 - 2349
  • [8] Improving detection accuracy of perfusion defect in standard dose SPECT-myocardial perfusion imaging by deep-learning denoising
    Liu, Junchi
    Yang, Yongyi
    Wernick, Miles N.
    Pretorius, P. Hendrik
    Slomka, Piotr J.
    King, Michael A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (05) : 2340 - 2349
  • [9] Deep learning with noise-to-noise training for denoising in SPECT myocardial perfusion imaging
    Liu, Junchi
    Yang, Yongyi
    Wernick, Miles N.
    Pretorius, P. Hendrik
    King, Michael A.
    MEDICAL PHYSICS, 2021, 48 (01) : 156 - 168
  • [10] Deep learning–based denoising of low-dose SPECT myocardial perfusion images: quantitative assessment and clinical performance
    Narges Aghakhan Olia
    Alireza Kamali-Asl
    Sanaz Hariri Tabrizi
    Parham Geramifar
    Peyman Sheikhzadeh
    Saeed Farzanefar
    Hossein Arabi
    Habib Zaidi