Rapid, Multispecies Detection of SARS-CoV-2 Antibodies via a Meta-Surface Plasmon Resonance Biosensor

被引:1
|
作者
Zhao, Ya [1 ,2 ]
Li, Rui [3 ]
Liu, Zuqing [1 ]
Zhou, Hanlin [4 ]
Yang, Jingyu [1 ]
Zhang, Shaoran [2 ]
Huang, Liping [3 ,4 ]
Liu, Gang L. [3 ]
Zhang, Qiang [1 ,5 ,6 ]
Jin, Meilin [1 ,2 ,5 ]
机构
[1] Huazhong Agr Univ, Coll Vet Med, Wuhan 430070, Peoples R China
[2] Huazhong Agr Univ, Natl Key Lab Agr Microbiol, Wuhan 430070, Peoples R China
[3] Huazhong Univ Sci & Technol, Coll Life Sci & Technol, 1037 Luo Yu Rd, Wuhan 430074, Peoples R China
[4] Liangzhun Shanghai Ind Co Ltd, 1582 Gu Mei Rd, Shanghai 200233, Peoples R China
[5] Hubei Jiangxia Lab, Wuhan 430200, Peoples R China
[6] Huazhong Agr Univ, Coll Biomed & Hlth, Wuhan 430070, Peoples R China
关键词
SPIKE;
D O I
10.1155/2024/9350822
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Public health concerns have been raised by numerous reports of severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) and its variations infecting a range of animals. Wildlife reservoirs may facilitate the evolution of viral types capable of causing human infection in the future. Therefore, epidemiological monitoring of animals in close contact with humans is necessary. Yet, infection symptoms are not obvious in most animals, which leads to a short nucleic acid test-detection period and limits the application of this method in animals. The use of virus- and pseudovirus-based neutralizing antibody detection techniques is restricted to establishments with elevated biosafety standards. Traditional enzyme-linked immunosorbent assays (ELISA) do not offer multispecies detection and are time-consuming and labor-intensive. This work developed a polyethyleneimine-gold nanoparticle meta-surface plasmon resonance biosensor system-based multispecies SARS-CoV-2 antibody detection platform that is fast, sensitive, has a high throughput, and is fully automated. The test can be done in 30 min and specificity is up to 100% for detection in cats, dogs, and minks. Moreover, the coincidence rate was up to 99.36% (313/315) for the detection of pseudovirus in clinical and immune sera. Additionally, this method's detection sensitivity in cat, dog, and mink serum is 2,048, 1,024, and 4,096 times, which is much better than indirect ELISA and comparable to indirect immunofluorescence assays. An efficient method for COVID-19 epidemiology screening in animal serum will be made available by this platform.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Numerical Analysis of a Highly Sensitive Surface Plasmon Resonance Sensor for SARS-CoV-2 Detection
    Uddin, Syed Mohammad Ashab
    Chowdhury, Sayeed Shafayet
    Kabir, Ehsan
    PLASMONICS, 2021, 16 (06) : 2025 - 2037
  • [22] High-Sensitivity Zinc-Based Surface Plasmon Resonance Biosensor for SARS-CoV-2 Detection Using Kretschmann Configuration
    Malakalapalli, Snehanagasri
    Santhosh, Chella
    Vasimalla, Yesudasu
    Balaji, Ramachandran
    Maloji, Suman
    Kumar, Santosh
    PLASMONICS, 2025,
  • [23] Numerical Study of Titanium Dioxide and MXene Nanomaterial-Based Surface Plasmon Resonance Biosensor for Virus SARS-CoV-2 Detection
    Swati Srivastava
    Sachin Singh
    Adarsh Chandra Mishra
    Pooja Lohia
    D. K. Dwivedi
    Plasmonics, 2023, 18 : 1477 - 1488
  • [24] Numerical Study of Titanium Dioxide and MXene Nanomaterial-Based Surface Plasmon Resonance Biosensor for Virus SARS-CoV-2 Detection
    Srivastava, Swati
    Singh, Sachin
    Mishra, Adarsh Chandra
    Lohia, Pooja
    Dwivedi, D. K.
    PLASMONICS, 2023, 18 (04) : 1477 - 1488
  • [25] Design and Modelling of Surface Plasmon Resonance Biosensor Employing BaTiO3 and Graphene Nanostructure for Detection of SARS-CoV-2 Virus
    Alaaudeen, K. M.
    Manoharadas, Salim
    Dhasarathan, Vigneswaran
    Rajeshkannan, S.
    PLASMONICS, 2024, 20 (2) : 709 - 719
  • [26] Rapid and sensitive detection of SARS-CoV-2 antibodies by biolayer interferometry
    John V. Dzimianski
    Nicholas Lorig-Roach
    Sara M. O’Rourke
    David L. Alexander
    Jacqueline M. Kimmey
    Rebecca M. DuBois
    Scientific Reports, 10
  • [27] Rapid and sensitive detection of SARS-CoV-2 antibodies by biolayer interferometry
    Dzimianski, John V.
    Lorig-Roach, Nicholas
    O'Rourke, Sara M.
    Alexander, David L.
    Kimmey, Jacqueline M.
    DuBois, Rebecca M.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [28] Biosensor for rapid detection of SARS-CoV-2 in real-world samples
    Forinova, Michala
    Pilipenco, Alina
    Visova, Ivana
    Kuncak, Jakub
    Lynn, N. Scott
    Yudin, Petr
    Dostalek, Jakub
    Honig, Vaclav
    Palus, Martin
    Maskova, Hana
    Dycka, Filip
    Sterba, Jan
    Vrabcova, Marketa
    Arnostova, Judita
    Spasovova, Monika
    Tung, Chao-Ping
    Yang, An-Suei
    Dejneka, Alexandr
    Vaisocherova-Lisalova, Hana
    2021 IEEE SENSORS, 2021,
  • [30] Detection of Penicillin via Surface Plasmon Resonance Biosensor
    Zhang Ying
    Jin Wei
    Yang Meng-chao
    Zhang Ti-qiang
    Zhou Chao
    Xie Fei
    Song Qi
    Ren Hao
    Jin Qin-han
    Mu Ying
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2012, 28 (05) : 792 - 796