Limited angular remodelling after in-situ fixation for slipped capital femoral epiphysis

被引:0
|
作者
Anderson, Mattias [1 ,2 ]
Herngren, Bengt [2 ,3 ]
Tropp, Hans [2 ,4 ]
Risto, Olof [2 ,3 ]
机构
[1] Univ Hosp, Dept Orthopaed, S-58185 Linkoping, Sweden
[2] Linkoping Univ, Dept Biomed & Clin Sci, Linkoping, Sweden
[3] Ryhov Cty Hosp, Futurum Acad Hlth & Care, Jonkoping Cty Council, Dept Orthopaed, Jonkoping, Sweden
[4] Linkoping Univ, Ctr Med Image Sci & Visualizat CMIV, Linkoping, Sweden
关键词
Slipped capital femoral epiphysis; SCFE; Remodelling; MODIFIED DUNN PROCEDURE; TERM-FOLLOW-UP; ACETABULAR CARTILAGE; CONTINUED GROWTH; IMPINGEMENT; ANGLE;
D O I
10.1186/s12891-023-07117-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundIn Sweden, most children with slipped capital femoral epiphysis (SCFE) are operated on with a single smooth pin or a short-threaded screw, allowing further growth of the femoral neck. Using the Swedish Pediatric Orthopaedic Quality registry, SPOQ, we investigated whether angular remodelling occurs adjacent to the proximal femoral epiphysis after fixation of SCFE using implants, allowing continued growth of the femoral neck.MethodsDuring 2008-2010 a total national population of 155 children were reported to the SPOQ registry. Following our strict inclusion criteria, radiographs of 51 hips were further assessed. The lateral Head Shaft Angle (HSA), the Notzli 3-point alpha-angle, the anatomic alpha-angle, and the Anterior Offset Ratio (AOR) on the first postoperative radiographs and at follow-up were measured to describe the occurrence of remodelling. Slip severity was categorised as mild, moderate or severe according to postoperative HSA.ResultsMean and SD values for the change in HSA were 3,7 degrees (5,0 degrees), for 3-point alpha-angle 6,8 degrees (8,9 degrees), and anatomic alpha-angle 13,0 degrees (16,3 degrees). The overall increase in AOR was 0,038 (0.069). There were no significant differences between the slip severity groups.ConclusionsWe found limited angular remodelling after in situ fixation with smooth pins or short threaded screws for SCFE. The angular remodelling and the reduction of the CAM deformity was less than previously described after fixation of SCFE with similar implants. Results about the same magnitude with non-growth sparing techniques suggest that factors other than longitudinal growth of the femoral neck are important for angular remodelling.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Gait abnormalities following slipped capital femoral epiphysis treated with in situ fixation
    Henry, Brice
    Detrembleur, Christine
    Mahaudens, Philippe
    Boulet, Sophie
    Docquier, Pierre-Louis
    GAIT & POSTURE, 2019, 69 : 156 - 161
  • [32] Prospective evaluation of in situ screw fixation for stable slipped capital femoral epiphysis
    DeVries, Clarabelle A.
    Badrinath, Raghav
    Baird, Samuel G.
    Bomar, James D.
    Upasani, Vidyadhar V.
    JOURNAL OF CHILDRENS ORTHOPAEDICS, 2022, 16 (05) : 385 - 392
  • [33] FIXATION WITH A SINGLE SCREW FOR SLIPPED CAPITAL FEMORAL EPIPHYSIS
    WARD, WT
    STEFKO, J
    WOOD, KB
    STANITSKI, CL
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06): : 799 - 809
  • [34] Factors Affecting Slip Progression After In Situ Screw Fixation of Stable Slipped Capital Femoral Epiphysis
    Makarewich, Christopher A.
    Wait, Eric S.
    Fedorak, Graham T.
    MacWilliams, Bruce A.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2022, 42 (05) : E414 - E420
  • [35] Displaced femoral neck fractures at the bone-screw interface after in situ fixation of slipped capital femoral epiphysis
    Canale, ST
    Casillas, M
    Banta, JV
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1997, 17 (02) : 212 - 215
  • [36] Slipped capital femoral epiphysis, fixation by single screw in situ: A kinematic and radiographic study
    Sangeux, Morgan
    Passmore, Elyse
    Gomez, Glenn
    Balakumar, Jitendra
    Graham, H. Kerr
    CLINICAL BIOMECHANICS, 2014, 29 (05) : 523 - 530
  • [37] Chondrolysis after slipped capital femoral epiphysis
    Warner, WC
    Beaty, JH
    Canale, ST
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 1996, 5 (03): : 168 - 172
  • [38] Technical note: bone marrow aspirate needle to assist in-situ screw fixation of slipped capital femoral epiphysis
    Watkins, Colyn J.
    Novais, Eduardo
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2021, 30 (02): : 123 - 125
  • [39] Temporal trends in surgical implants for in situ fixation of stable slipped capital femoral epiphysis
    Chervonski, Ethan
    Wingo, Taylor
    Pargas-Colina, Carlos
    Castaneda, Pablo
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2024, 33 (05): : 437 - 442
  • [40] Slipped capital femoral epiphysis: Physeal histologic features before and after fixation
    Guzzanti, V
    Falciglia, F
    Stanitski, CL
    Stanitski, DF
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2003, 23 (05) : 571 - 577