Limited angular remodelling after in-situ fixation for slipped capital femoral epiphysis

被引:0
|
作者
Anderson, Mattias [1 ,2 ]
Herngren, Bengt [2 ,3 ]
Tropp, Hans [2 ,4 ]
Risto, Olof [2 ,3 ]
机构
[1] Univ Hosp, Dept Orthopaed, S-58185 Linkoping, Sweden
[2] Linkoping Univ, Dept Biomed & Clin Sci, Linkoping, Sweden
[3] Ryhov Cty Hosp, Futurum Acad Hlth & Care, Jonkoping Cty Council, Dept Orthopaed, Jonkoping, Sweden
[4] Linkoping Univ, Ctr Med Image Sci & Visualizat CMIV, Linkoping, Sweden
关键词
Slipped capital femoral epiphysis; SCFE; Remodelling; MODIFIED DUNN PROCEDURE; TERM-FOLLOW-UP; ACETABULAR CARTILAGE; CONTINUED GROWTH; IMPINGEMENT; ANGLE;
D O I
10.1186/s12891-023-07117-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundIn Sweden, most children with slipped capital femoral epiphysis (SCFE) are operated on with a single smooth pin or a short-threaded screw, allowing further growth of the femoral neck. Using the Swedish Pediatric Orthopaedic Quality registry, SPOQ, we investigated whether angular remodelling occurs adjacent to the proximal femoral epiphysis after fixation of SCFE using implants, allowing continued growth of the femoral neck.MethodsDuring 2008-2010 a total national population of 155 children were reported to the SPOQ registry. Following our strict inclusion criteria, radiographs of 51 hips were further assessed. The lateral Head Shaft Angle (HSA), the Notzli 3-point alpha-angle, the anatomic alpha-angle, and the Anterior Offset Ratio (AOR) on the first postoperative radiographs and at follow-up were measured to describe the occurrence of remodelling. Slip severity was categorised as mild, moderate or severe according to postoperative HSA.ResultsMean and SD values for the change in HSA were 3,7 degrees (5,0 degrees), for 3-point alpha-angle 6,8 degrees (8,9 degrees), and anatomic alpha-angle 13,0 degrees (16,3 degrees). The overall increase in AOR was 0,038 (0.069). There were no significant differences between the slip severity groups.ConclusionsWe found limited angular remodelling after in situ fixation with smooth pins or short threaded screws for SCFE. The angular remodelling and the reduction of the CAM deformity was less than previously described after fixation of SCFE with similar implants. Results about the same magnitude with non-growth sparing techniques suggest that factors other than longitudinal growth of the femoral neck are important for angular remodelling.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] The outcome of in-situ fixation of unstable slipped capital femoral epiphysis
    Lang, Pamela
    Panchal, Hemali
    Delfosse, Erin M.
    Silva, Mauricio
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2019, 28 (05): : 452 - 457
  • [2] Slipped capital femoral epiphysis: long-term outcome and remodelling after in situ fixation
    Reinhardt, Max
    Stauner, Kerstin
    Schuh, Alexander
    Steger, Wolfgang
    Schraml, Annemarie
    HIP INTERNATIONAL, 2016, 26 (01) : 25 - 30
  • [3] Growth and Deformity after In Situ Fixation of Slipped Capital Femoral Epiphysis
    Druschel, C.
    Placzek, R.
    Funk, J. F.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2013, 151 (04): : 371 - 379
  • [4] PERCUTANEOUS IN SITU FIXATION OF SLIPPED CAPITAL FEMORAL EPIPHYSIS
    Chlebeck, Jesse D.
    Birch, Christopher E.
    Lisle, Jennifer W.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2016, 6 (01):
  • [5] A Simple Modified Technique for In-Situ Screw Fixation in Slipped Capital Femoral Epiphysis
    K. Venkatadass
    V. Durga Prasad
    Chirag Parsana
    A. Gomathi
    S. Rajasekaran
    Indian Journal of Orthopaedics, 2021, 55 : 1022 - 1027
  • [6] A Simple Modified Technique for In-Situ Screw Fixation in Slipped Capital Femoral Epiphysis
    Venkatadass, K.
    Prasad, V. Durga
    Parsana, Chirag
    Gomathi, A.
    Rajasekaran, S.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (04) : 1022 - 1027
  • [7] Limited angular remodelling after in-situ fixation for slipped capital femoral epiphysisA study on radiographs from the Swedish pediatric orthopaedic quality registry for SCFE
    Mattias Anderson
    Bengt Herngren
    Hans Tropp
    Olof Risto
    BMC Musculoskeletal Disorders, 25
  • [8] In situ fixation of the slipped capital femoral epiphysis with a single screw
    Stevens, DB
    Short, BA
    Burch, JM
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 1996, 5 (02): : 85 - 89
  • [9] In situ fixation of slipped capital femoral epiphysis with Steinmann pins
    Lehmann, Trude G.
    Engesaeter, Ingvild O.
    Laborie, Lene B.
    Rosendahl, Karen
    Lie, Stein Atle
    Engesaeter, Lars B.
    ACTA ORTHOPAEDICA, 2011, 82 (03) : 333 - 338
  • [10] In Situ Fixation for Slipped Capital Femoral Epiphysis Perspectives in 2011
    Millis, Michael B.
    Novais, Eduardo N.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A : 46 - 51