Activity standardisation of 177Lu

被引:1
|
作者
Nedjadi, Youcef [1 ]
Juget, Frederic [1 ]
Duran, M. Teresa [1 ]
Desorgher, Laurent [1 ]
Bochud, Francois [1 ]
Bailat, Claude [1 ]
机构
[1] Inst Radiophys, Lausanne, Switzerland
关键词
Activity standardisation; 4 pi ss-4 pi gamma coincidence counting; Plastic scintillation; TDCR; Lu-177; ENERGY ELECTRONS; DECAY DATA; TB-161;
D O I
10.1016/j.apradiso.2023.110986
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Lu-177 decays through low-energy ss-and gamma-emissions in addition to conversion and Auger electrons. To support the use of this radiopharmaceutical in Switzerland, a Lu-177 solution was standardised using the ss-gamma coincidence technique, as well as the TDCR method. The solution had no Lu-177m impurity. Primary coincidence measurements, with plastic scintillators for beta detection, were carried out using both analogue and digital electronics. TDCR measurements using only defocusing were also made. Monte Carlo calculations were used to compute the detection efficiency. The coincidence measurements with both analogue and digital electronics are compatible within one standard uncertainty, but they are lower than (and discrepant with) the TDCR measurements. An ampoule of this solution was submitted to the BIPM as a contribution to the Systeme International de Reference.
引用
收藏
页数:11
相关论文
共 50 条
  • [32] Quantifying the impact of residual activity on therapeutic index: an updated dosimetric comparison between [177Lu]Lu-PSMA-10.1 and [177Lu]Lu-PSMA I&T
    Rinscheid, A.
    Dierks, A.
    Kircher, M.
    Pfob, C.
    Bundschuh, R. A.
    Lapa, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S811 - S812
  • [33] Accuracy of 177Lu activity quantification in SPECT imaging: a phantom study
    Uribe, Carlos F.
    Esquinas, Pedro L.
    Tanguay, Jesse
    Gonzalez, Marjorie
    Gaudin, Emilie
    Beauregard, Jean-Mathieu
    Celler, Anna
    EJNMMI PHYSICS, 2017, 4
  • [34] Quantitative SPECT/CT reconstruction for 177Lu and 177Lu/90Y targeted radionuclide therapies
    Shcherbinin, S.
    Piwowarska-Bilska, H.
    Celler, A.
    Birkenfeld, B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (18): : 5733 - 5747
  • [35] Incorporation Of 177Lu During Care Of 177Lu-PSMA And 177Lu-DOTATATE Therapy Patients
    Happel, C.
    Kranert, W. T.
    Bockisch, B.
    Kratzel, U.
    Baumgarten, J.
    Ngoc, C. Nguyen
    Garayev, E.
    Gruenwald, F.
    Sabet, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S842 - S843
  • [36] Phantom study for activity quantification of 177Lu SPECT/CT imaging
    Ferrando, O.
    Chimenz, A.
    Riondato, M.
    Rambaldi, G.
    Foppiano, F.
    Ciarmiello, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S823 - S823
  • [37] Production of no-carrier-added 177Lu via the 176Yb(n,γ)177Yb→177Lu process
    Hashimoto, K
    Matsuoka, H
    Uchida, S
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 255 (03) : 575 - 579
  • [38] Accuracy of 177Lu activity quantification in SPECT imaging: a phantom study
    Carlos F. Uribe
    Pedro L. Esquinas
    Jesse Tanguay
    Marjorie Gonzalez
    Emilie Gaudin
    Jean-Mathieu Beauregard
    Anna Celler
    EJNMMI Physics, 4
  • [39] Modelling of the 177mLu/177Lu radionuclide generator
    Bhardwaj, Rupali
    Wolterbeek , Hubert T.
    Denkova, Antonia G.
    Serra-Crespo, Pablo
    APPLIED RADIATION AND ISOTOPES, 2020, 166
  • [40] Production of 177Lu at the new research reactor FRM-II:: Irradiation yield of 176Lu(n, γ)177Lu
    Dvorakova, Z.
    Henkelmann, R.
    Lin, X.
    Tuerler, A.
    Gerstenberg, H.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (02) : 147 - 151