Solidification analysis in an ice-on-coil ice storage system: Experimental and numerical approaches

被引:8
|
作者
Ajarostaghi, Seyed Soheil Mousavi [1 ,2 ]
Poncet, Sebastien [1 ]
Sedighi, Kurosh [2 ]
Amiri, Leyla [1 ]
机构
[1] Univ Sherbrooke, Mech Engn Dept, Sherbrooke, PQ, Canada
[2] Babol Noshirvani Univ Technol, Mech Engn Dept, Babol, Iran
关键词
Cooling thermal energy storage (CTES); Ice-on-coil; Coil tube heat exchanger; Solidification; Phase change material (PCM) (-); HEAT-TRANSFER; TRIPLEX TUBE; PCM;
D O I
10.1016/j.est.2023.107291
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Rapid economic growth has led to energy resources shortages, creating unique challenges for developing countries whose activities depend on energy. Thermal energy storage is an important field of technology that can be deployed as a reliable method to decrease net energy usage. For example, ice storage systems are one of the most efficient methods for saving cold energy. In this work, a combined experimental and numerical study has been carried out on the freezing process or solidification as charge mode in a novel ice-on-coil cold storage system with coil tube. Initial experimental results show that the initially designed evaporator, horizontal shell and coil tube heat exchanger (used to transfer cold energy between a mixture of water/ethylene glycol and refrigerant) failed to form uniform ice on the outer surface of the coil tube inside the ice tank. Also, the thickness of ice decreases from the top to the bottom of the coil, while trying to create a uniform thickness of ice around the coil is one of the main challenges in improving the performance of the proposed cold storage system. In the second part of this work, baffles are inserted inside the evaporator to create transverse fluid flows and to prevent shortcut flow, which leads to better heat transfer rates and, consequently, more uniform ice production around the coil tube. The results depict that although baffle placement demonstrates a slightly positive impact on improving the ice thickness along the coil, overall, it fails to eliminate the non-uniformity of ice production along the entire length of the coil tube. In the third section, a modified evaporator with four connected horizontal-placed coils is employed. According to the obtained results, it can be concluded that after 180 min, by employing the modified evaporator, ice thickness has increased by 14.71, 13.51, and 3.39 % in the bottom, middle, and top of the coil, respectively. It can be seen that utilizing the modified version of evaporator with four horizontal-placed coils leads to enhancement in the ice thickness specially at the bottom of the coil where the ice thickness is less than for the rest of the examined points, which was considered as one of the weaknesses of the primary system. Finally, in the last section, to realize better the solidification process around the coil tube inside the ice storage tank, the ice production process is modeled by performing three-dimensional simulations based on the finite volume method. The proposed model is then validated by using the experimental results.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Numerical and Experimental Study on a High-Power Cold Achieving Process of a Coil-Plate Ice-Storage System
    Guo, Liang
    Ye, Hong
    ENERGIES, 2019, 12 (21)
  • [42] Numerical Heat Transfer Analysis of Flake Ice Storage system with Nanofluids
    Zhao, Jingde
    Liu, Ni
    Wang, Yi
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 2716 - +
  • [43] Experimental investigations on the thermal performance of an ice storage system using twin concentric helical coil
    Abdelrahman, H. E.
    Refaey, H. A.
    Alotaibi, A.
    Abdel-Aziz, Ali A.
    Abd Rabbo, M. F.
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [44] Influence of transient inlet system on melting performance and pressure reduction in ice-on-coil latent thermal energy systems
    Awasthi, Abhishek
    Suresh, C.
    Jeon, Yongseok
    APPLIED THERMAL ENGINEERING, 2025, 263
  • [45] EXPERIMENTAL AND NUMERICAL ANALYSIS OF ICE CRUSHING TESTS WITH DIFFERENT SHAPED ICE SPECIMENS
    Mueller, Franciska
    Boehm, Angelo
    Herrnring, Hauke
    von Bock Und Polach, Franz
    Ehlers, Soeren
    PROCEEDINGS OF ASME 2023 42ND INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE & ARCTIC ENGINEERING, OMAE2023, VOL 6, 2023,
  • [46] Heat transfer enhancement of direct-evaporation internal melt ice-on-coil thermal storage tank during discharging process
    Key Laboratory of Renewable Energy and Gas Hydrate, Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
    不详
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2008, 29 (09): : 1524 - 1526
  • [47] NUMERICAL SIMULATION OF THE MELTING PROCESS IN A SHELL AND COIL TUBE ICE STORAGE SYSTEM FOR AIR-CONDITIONING APPLICATION
    Ajarostaghi, S. S. Mousavi
    Poncet, S.
    Delavar, M. A.
    Sedighi, K.
    12TH IIR/IIF INTERNATIONAL CONFERENCE ON PHASE-CHANGE MATERIALS AND SLURRIES FOR REFRIGERATION AND AIR CONDITIONING (PCM 2018), 2018, : 157 - 165
  • [48] Numerical Modeling of the Melting Process in a Shell and Coil Tube Ice Storage System for Air-Conditioning Application
    Ajarostaghi, Seyed Soheil Mousavi
    Poncet, Sebastien
    Sedighi, Kurosh
    Delavar, Mojtaba Aghajani
    APPLIED SCIENCES-BASEL, 2019, 9 (13):
  • [49] Increasing ice production speed of a seasonal ice storage device based on experimental test and numerical simulation
    Huang, Kailiang
    Wei, Jiaxing
    Feng, Guohui
    Ding, Chenjun
    Li, Zhaoxing
    Li, Xiaoxu
    Liu, Xin
    JOURNAL OF ENERGY STORAGE, 2023, 72
  • [50] Experimental and theoretical investigations of solidification and melting of ice for the design and operation of an ice store
    Koller, Torsten
    Spindler, Klaus
    Mueller-Steinhagen, Hans
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (05): : 1253 - 1265