Closely Fitted 16-Channel Breast Array for MRI

被引:1
|
作者
Narongrit, Folk W. [1 ]
Ramesh, Thejas Vishnu [2 ]
Rispoli, Joseph V. [1 ,3 ]
机构
[1] Purdue Univ, Elmore Family Sch Elect & Comp Engn, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[3] Univ Virginia, Radiol & Med Imaging, Charlottesville, VA USA
关键词
MRI; RF Coils; Signal-to-Noise Ratio; Breast Imaging;
D O I
10.1109/IMBIOC56839.2023.10304880
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: We propose a 16-channel bilateral breast coil array prototype for high-resolution MR imaging at 3T. This coil aims to improve signal-to-noise ratio (SNR) by positioning the coil array close to the breast. Methods: Sixteen 80-mm coil elements made on flexible printed circuit boards were placed on top of a 3D-printed plastic housing modeled to fit most cup sizes. Match, tune, and detune elements were incorporated onto the coil. Phantom and in-vivo scans were performed to demonstrate the SNR profile and clinical efficacy of the coil. Conclusion: The in-vivo images show high sensitivity and coverage of the breast, and the SNR profile evaluated from the phantom images was relatively uniform throughout the imaging volume.
引用
收藏
页码:40 / 42
页数:3
相关论文
共 50 条
  • [11] Chronic Dopamine Detection With a 16-Channel Carbon Fiber Microelectrode Array
    Popov, Pavlo
    Patel, Paras
    Cai, Dawen
    Becker, Jill
    Chestek, Cynthia
    NEUROPSYCHOPHARMACOLOGY, 2018, 43 : S521 - S522
  • [12] A 16-Channel 13C Array Coil for Magnetic Resonance Spectroscopy of the Breast at 7T
    Wilcox, Matthew
    Ogier, Stephen
    Cheshkov, Sergey
    Dimitrov, Ivan
    Malloy, Craig
    Wright, Steven
    McDougall, Mary
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (06) : 2036 - 2046
  • [13] Experimental demonstration of a 16-channel DFB laser array based on nanoimprint technology
    Zhao, Jianyi
    Chen, Xin
    Zhou, Ning
    Qian, Kun
    Wang, Lei
    Huang, Xiaodong
    Liu, Wen
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 2013, 28 (05)
  • [14] Performance of 16-channel, photonic, phased-array antenna calibration system
    McDermitt, C. S.
    Dorsey, W. M.
    Godinez, M. E.
    Bucholtz, F.
    Parent, M. G.
    ELECTRONICS LETTERS, 2009, 45 (24) : 1249 - U81
  • [15] A reconfigurable FPGA-based 16-channel front-end for MRI
    Dalal, Ishaan L.
    Fontaine, Fred L.
    2006 FORTIETH ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS AND COMPUTERS, VOLS 1-5, 2006, : 1860 - +
  • [16] Realization of 16-channel digital PGC demodulator for fiber laser sensor array
    Wang, Lin
    He, Jun
    Li, Fang
    Liu, Yu-Liang
    3RD INTERNATIONAL PHOTONICS AND OPTOELECTRONICS MEETINGS (POEM 2010), 2011, 276
  • [17] A patient-friendly 16-channel transmit/64-channel receive coil array for combined head-neck MRI at 7 Tesla
    May, Markus W.
    Hansen, Sam-Luca J. D.
    Mahmutovic, Mirsad
    Scholz, Alina
    Kutscha, Nicolas
    Guerin, Bastien
    Stockmann, Jason P.
    Barry, Robert L.
    Kazemivalipour, Ehsan
    Gumbrecht, Rene
    Kimmlingen, Ralph
    Adriany, Markus
    Chang, Yulin
    Triantafyllou, Christina
    Knake, Susanne
    Wald, Lawrence L.
    Keil, Boris
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (03) : 1419 - 1433
  • [18] EXTRACOCHLEAR 16-CHANNEL ELECTRODE SYSTEM
    BANFAI, P
    KARCZAG, A
    KUBIK, S
    LUERS, P
    SURTH, W
    OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 1986, 19 (02) : 371 - 408
  • [19] A 16-Channel Programmable Antialiasing Amplifier
    Boiano, C.
    Guazzoni, C.
    Guazzoni, P.
    Zetta, L.
    Pagano, A.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1389 - 1391
  • [20] 16-Channel micro magnetic flux sensor array for IGBT current distribution measurement
    Tomonaga, H.
    Tsukuda, M.
    Okoda, S.
    Noda, R.
    Tashiro, K.
    Omura, I.
    MICROELECTRONICS RELIABILITY, 2015, 55 (9-10) : 1357 - 1362