Improved operating strategies for the optimization of PEMFC system performance

被引:7
|
作者
Soubeyran, G. [1 ]
Micoud, F. [1 ]
Morin, B. [1 ]
Reytier, M. [1 ]
Poirot-Crouvezier, J. [1 ]
机构
[1] Univ Grenoble Alpes, CEA, Liten, F-38000 Grenoble, France
关键词
Durability; PEMFC; Recovery procedure; Reversible degradations; Efficiency; MEMBRANE FUEL-CELLS; DEGRADATION; DISSOLUTION;
D O I
10.1016/j.jpowsour.2024.234089
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The formation of platinum oxides at PEMFC working cathode potential is one of the main sources of reversible performance loss during operation as this mechanism passivates active surface. Therefore, promoting the electrochemical reduction of these oxides during operation is a solution to increase performance and mitigate reversible losses related to this phenomenon. Thus, a feasible solution to achieve this result in a PEMFC stack and system is to apply frequent and short operating phases with reduced air supply at the cathode. This procedure, called "air starvation" enables the decrease of cathode potential from nominal potential to approximately 0 V vs. RHE, promoting the electrochemical reduction of platinum oxides. This study focuses on the optimization of recovery parameters, first at small single cell scale and then at short-stack scale with air starvation procedure.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Iterative Optimization for a Hybrid PEMFC Power System
    Yang, Y. Z.
    Chen, P. J.
    Lin, C. S.
    Wang, F. C.
    2017 56TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2017, : 1479 - 1484
  • [32] Improving system performance through operating system optimization on embedded devices platform
    Daud, Shuhaizar
    Khalib, Zahereel Ishwar Abdul
    Ahmad, R. Badlishah
    2008 INTERNATIONAL CONFERENCE ON COMPUTER AND COMMUNICATION ENGINEERING, VOLS 1-3, 2008, : 1010 - 1015
  • [33] Improved sensitivity of thin film sensor for humidity measurement inside a operating PEMFC
    Hasegawa, Noriyoshi
    Otsuki, Yota
    Kurosu, Masato
    Araki, Takuto
    18TH INTERNATIONAL CONFERENCE ON MICRO AND NANOTECHNOLOGY FOR POWER GENERATION AND ENERGY CONVERSION APPLICATIONS, 2019, 1407
  • [34] Improved fish migration optimization method to identify PEMFC parameters
    Zhou, Jincheng
    Ali, Masood Ashraf
    Sharma, Kamal
    Alizadeh, As'ad
    Almojil, Sattam Fahad
    Almohana, Abdulaziz Ibrahim
    Alali, Abdulrhman Fahmi
    Almoalimi, Khaled Twfiq
    Ibrahim, Banar Fareed
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (52) : 20028 - 20040
  • [35] Optimization of air-conditioning system operating strategies for hot and humid climates
    Huh, Jung-Ho
    Brandemuehl, Michael J.
    ENERGY AND BUILDINGS, 2008, 40 (07) : 1202 - 1213
  • [36] The impact of operating parameters and system architecture on the water management of a multifunctional PEMFC system
    Werner, Claudia
    Busemeyer, Lucas
    Kallo, Josef
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (35) : 11595 - 11603
  • [37] EXPERIMENTAL AND NUMERICAL INVESTIGATION OF THE EFFECT OF VARIABLE OPERATING CONDITIONS ON PEMFC PERFORMANCE
    Kahraman, Huseyin
    THERMAL SCIENCE, 2023, 27 (4B): : 3089 - 3100
  • [38] Numerical Study of Effects of Operating Conditions on the Performance of High Temperature PEMFC
    Kim, Kyoungyoun
    Sohn, Young-Jun
    Kim, Minjin
    Yang, Tae-Hyun
    JOURNAL OF THE KOREAN ELECTROCHEMICAL SOCIETY, 2010, 13 (04): : 283 - 289
  • [39] Pemfc performance optimization based on frequency of secant angle
    Gao, Zhi
    Wei, Dong
    Wang, Zhen
    Tong, Peng
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (08): : 2376 - 2382
  • [40] Optimization of structural combinations on the performance of a PEMFC's MEA
    Akyalcin, Levent
    Kaytakoglu, Suleyman
    JOURNAL OF POWER SOURCES, 2008, 180 (02) : 767 - 772