Physics and small-scale dosimetry of α-emitters for targeted radionuclide therapy: The case of 211At

被引:0
|
作者
Alcocer-Avila, Mario Enrique [1 ,5 ]
Larouze, Alexandre [1 ]
Groetz, Jean-Emmanuel [2 ]
Hindie, Elif [3 ,4 ]
Champion, Christophe [1 ]
机构
[1] Univ Bordeaux, Ctr Lasers Intenses & Applicat UMR CNRS CEA 5107, Talence, France
[2] Univ Bourgogne Franche Comte, Lab Chronoenvironm UMR CNRS 6249, Besancon, France
[3] Univ Bordeaux, CHU Bordeaux Serv Med Nucl, INCIA, Pessac, France
[4] Inst Univ France, Paris, France
[5] Univ Claude Bernard Lyon 1, Inst Phys Infinis Lyon 2, 4 Rue Enrico Fermi, F-69622 Villeurbanne, France
关键词
alpha-emitters; alpha-particles; astatine-211; Monte Carlo simulation; radiation dosimetry; S-values; targeted radionuclide therapy; LIQUID WATER; CELL-MEMBRANE; ELECTRON; ENERGY; PARTICLE; IONIZATION; MICROMETASTASES; HYDROGEN; SYSTEM; BEAMS;
D O I
10.1002/mp.17016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Monte Carlo simulations have been considered for a long time the gold standard for dose calculations in conventional radiotherapy and are currently being applied for the same purpose in innovative radiotherapy techniques such as targeted radionuclide therapy (TRT). Purpose: We present in this work a benchmarking study of the latest version of the Transport d'Ions Lourds Dans l'Aqua & Vivo (TILDA-V) Monte Carlo track structure code, highlighting its capabilities for describing the full slowing down of alpha-particles in water and the energy deposited in cells by alpha-emitters in the context of TRT. Methods: We performed radiation transport simulations of alpha-particles (10 keV u(-1)-100 MeV u(-1)) in water with TILDA-V and the Particle and Heavy Ion Transport code System (PHITS) version 3.33. We compared the predictions of each code in terms of track parameters (stopping power, range and radial dose profiles) and cellular S-values of the promising radionuclide astatine-211 (At-211). Additional comparisons were made with available data in the literature. Results: The stopping power, range and radial dose profiles of alpha-particles computed with TILDA-V were in excellent agreement with other calculations and available data. Overall, minor differences with PHITS were ascribed to phase effects, that is, related to the use of interaction cross sections computed for water vapor or liquid water. However, important discrepancies were observed in the radial dose profiles of monoenergetic alpha-particles, for which PHITS results showed a large underestimation of the absorbed dose compared to other codes and experimental data. The cellular S-values of At-211 computed with TILDA-V agreed within 4% with the values predicted by PHITS and MIRDcell. Conclusions: The validation of the TILDA-V code presented in this work opens the possibility to use it as an accurate simulation tool for investigating the interaction of alpha-particles in biological media down to the nanometer scale in the context of medical research. The code may help nuclear medicine physicians in their choice of alpha-emitters for TRT. Further research will focus on the application of TILDA-V for quantifying radioinduced damage on the deoxyribonucleic acid (DNA) molecule.
引用
收藏
页码:5007 / 5019
页数:13
相关论文
共 50 条
  • [31] The application of polymer gel dosimeters to dosimetry for targeted radionuclide therapy
    Gear, J. I.
    Flux, G. D.
    Charles-Edwards, E.
    Partridge, M.
    Cook, G.
    Ott, R. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14): : 3503 - 3516
  • [32] Impact of Mouse Model on Preclinical Dosimetry in Targeted Radionuclide Therapy
    Boutaleb, Samir
    Pouget, Jean-Pierre
    Hindorf, Cecilia
    Pelegrin, Andre
    Barbet, Jacques
    Kotzki, Pierre-Olivier
    Bardies, Manuel
    PROCEEDINGS OF THE IEEE, 2009, 97 (12) : 2076 - 2085
  • [33] Comparison of Sequential SPECT and CT for Targeted Radionuclide Therapy Dosimetry
    Li, T.
    Leong, K.
    Ao, E.
    Mok, G. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S333 - S333
  • [34] Evaluation of sequential SPECT and CT for targeted radionuclide therapy dosimetry
    Li, Tiantian
    Wu, Nien-Yun
    Song, Na
    Mok, Greta S. P.
    ANNALS OF NUCLEAR MEDICINE, 2018, 32 (01) : 34 - 43
  • [35] Quantitative Imaging for Targeted Radionuclide Therapy Dosimetry - Technical Review
    Li, Tiantian
    Ao, Edwin C. I.
    Lambert, Bieke
    Brans, Boudewijn
    Vandenberghe, Stefaan
    Mok, Greta S. P.
    THERANOSTICS, 2017, 7 (18): : 4551 - 4565
  • [36] Evaluation of sequential SPECT and CT for targeted radionuclide therapy dosimetry
    Tiantian Li
    Nien-Yun Wu
    Na Song
    Greta S. P. Mok
    Annals of Nuclear Medicine, 2018, 32 : 34 - 43
  • [37] ARE MONOCLONAL ANTIBODIES SUITABLE IN TARGETED RADIONUCLIDE THERAPY USING ALPHA EMITTERS?
    Kumar, Divesh
    INTERNAL MEDICINE JOURNAL, 2023, 53 : 69 - 70
  • [38] Targeted Radionuclide Therapy Using Auger Electron Emitters: The Quest for the Right Vector and the Right Radionuclide
    Idrissou, Malick Bio
    Pichard, Alexandre
    Tee, Bryan
    Kibedi, Tibor
    Poty, Sophie
    Pouget, Jean-Pierre
    PHARMACEUTICS, 2021, 13 (07)
  • [39] Quantification of activity by alpha-camera imaging and small-scale dosimetry within ovarian carcinoma micrometastases treated with targeted alpha therapy
    Chouin, N.
    Lindegren, S.
    Jensen, H.
    Albertsson, P.
    Back, T.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 56 (06): : 487 - 495
  • [40] High Performance Virtual CT for Enhanced Targeted Radionuclide Therapy Dosimetry
    Mok, Greta
    Li, Tiantian
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58