3D SHINKEI MR neurography in evaluation of traumatic brachial plexus

被引:1
|
作者
Zhang, Yizhe [1 ]
Li, Xiaona [1 ]
Liu, Ying [1 ]
Sun, Yingcai [1 ]
Duan, Luyao [1 ]
Zhang, Yingshuai [1 ]
Shi, Ruiqing [1 ]
Yu, Xiaoman [1 ]
Peng, Zhigang [1 ]
机构
[1] Hebei Med Univ, Hosp 3, Dept Radiol, 139 Ziqiang Rd, Shijiazhuang 050051, Hebei, Peoples R China
关键词
MAGNETIC-RESONANCE NEUROGRAPHY; PERIPHERAL-NERVE; INJURY;
D O I
10.1038/s41598-024-57022-0
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
3D SHINKEI neurography is a new sequence for imaging the peripheral nerves. The study aims at assessing traumatic brachial plexus injury using this sequence. Fifty-eight patients with suspected trauma induced brachial plexus injury underwent MR neurography (MRN) imaging in 3D SHINKEI sequence at 3 T. Surgery and intraoperative somatosensory evoked potentials or clinical follow-up results were used as the reference standard. MRN, surgery and electromyography (EMG) findings were recorded at four levels of the brachial plexus-roots, trunks, cords and branches. Fifty-eight patients had pre- or postganglionic injury. The C5-C6 nerve postganglionic segment was the most common (average 42%) among the postganglionic injuries detected by 3D SHINKEI MRN. The diagnostic accuracy (83.75%) and the specificity (90.30%) of MRN higher than that of EMG (p < 0.001). There was no significant difference in the diagnostic sensitivity of MRN compared with EMG (p > 0.05). Eighteen patients with brachial plexus injury underwent surgical exploration after MRN examination and the correlation between MRN and surgery was 66.7%. Due to the high diagnostic accuracy and specificity, 3D SHINKEI MRN can comprehensively display the traumatic brachial plexus injury. This sequence has great potential in the accurate diagnosis of traumatic brachial plexus injury.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging
    Muertz, P.
    Kaschner, M.
    Lakghomi, A.
    Gieseke, J.
    Willinek, W. A.
    Schild, H. H.
    Thomas, D.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (04) : 696 - 702
  • [42] Thoracic outlet syndrome in 3T MR neurography-fibrous bands causing discernible lesions of the lower brachial plexus
    Baumer, P.
    Kele, H.
    Kretschmer, T.
    Koenig, R.
    Pedro, M.
    Bendszus, M.
    Pham, M.
    EUROPEAN RADIOLOGY, 2014, 24 (03) : 756 - 761
  • [43] The Application of ContrastEnhanced 3D-STIR-VISTA MR Imaging of the Brachial Plexus
    Han, Dingsheng
    Zhou, Yanru
    Zhang, Lan
    Zhang, Jiajia
    JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY, 2022, 106 (01):
  • [44] Clinical Evaluation of Balance in Adults with Traumatic Brachial Plexus Injury
    Verma, Chhaya
    Kini, Raveena
    Jadhav, Kshitija
    Mehta, Amita
    Puri, Vinita
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2019, 8 (04): : 61 - 68
  • [45] Diagnostic performance of diffusion-weighted MR neurography as an adjunct to conventional MRI for the assessment of brachial plexus pathology
    Kwee, Robert M.
    Borghans, Rob A. P.
    Bruls, Rik J. M.
    Fasen, Bram A. C. M.
    Kuburic, Damir
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2791 - 2797
  • [46] Diagnostic performance of diffusion-weighted MR neurography as an adjunct to conventional MRI for the assessment of brachial plexus pathology
    Robert M. Kwee
    Rob A. P. Borghans
    Rik J. M. Bruls
    Bram A. C. M. Fasen
    Damir Kuburic
    European Radiology, 2022, 32 : 2791 - 2797
  • [47] High-Resolution 3-T MR Neurography of the Lumbosacral Plexus
    Soldatos, Theodoros
    Andreisek, Gustav
    Thawait, Gaurav K.
    Guggenberger, Roman
    Williams, Eric H.
    Carrino, John A.
    Chhabra, Avneesh
    RADIOGRAPHICS, 2013, 33 (04) : 967 - 987
  • [48] MR EVALUATION OF BRACHIAL PLEXOPATHY FOLLOWING TRAUMATIC DELIVERY
    MILLER, SF
    GLASIER, CM
    STARK, JE
    GRIEBEL, ML
    RADIOLOGY, 1992, 185 : 185 - 185
  • [49] Diagnostic performance of deep learning–based reconstruction algorithm in 3D MR neurography
    Falko Ensle
    Malwina Kaniewska
    Anja Tiessen
    Maelene Lohezic
    Jonas M. Getzmann
    Roman Guggenberger
    Skeletal Radiology, 2023, 52 : 2409 - 2418
  • [50] Evaluation of the sacral nerve plexus in pelvic endometriosis by three-dimensional MR neurography
    Zhang, Xiaoling
    Li, Meizhi
    Guan, Jian
    Wang, Huanjun
    Li, Shurong
    Guo, Yan
    Liu, Mingjuan