OVERVIEW OF MODERN SENSORS FOR CONTINUOUS GLUCOSE MONITORING

被引:0
|
作者
Momynaliev, Kuvat T. [1 ]
Prokopiev, Maxim V. [1 ]
Ivanov, Igor V. [1 ]
机构
[1] All Russian Sci Res & Testing Inst Med Devices, Moscow, Russia
来源
DIABETES MELLITUS | 2023年 / 26卷 / 06期
关键词
diabetes mellitus; continuous glucose monitoring; sensor; medical device; registration; PROSPECTIVE MULTICENTER EVALUATION; ACCURACY; ADOLESCENTS; PRECISE; ADULTS; STILL;
D O I
10.14341/DM13043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The incidence of diabetes is increasing in all age groups. The use of technological devices for the treatment of diabetes, such as continuous glucose monitoring (CGM), is expanding and is associated with improved control of blood glucose levels in order to prevent complications of this disease. Reducing glycemic variability and maintaining optimal glycemic control is critical to the management of patients with type 1 diabetes. The usefulness of glycemic monitoring devices has also been shown for patients with type 2 diabetes. CGM technology is constantly being improved in terms of analytical performance, biocompatibility, wear duration, safety and clinical performance. However, commonly used minimally invasive CGMs do not measure blood glucose directly, but instead measure the glucose concentration in the interstitial fluid (IF), so changes in IF glucose occur with a delay of 5 to 15 minutes compared to blood glucose. In addition, the lifetime of minimally invasive CGM sensors is relatively short, up to 14 days. Therefore, the introduction into clinical practice of devices for non-invasive glucose measurement in people with diabetes, which overcome the above-mentioned limitations of minimally invasive CGM, will expand the possibilities of glucose monitoring among patients with diabetes. The purpose of this review was to present the technologies of CGM system sensors approved for medical use in Russia and other countries.
引用
收藏
页码:575 / 584
页数:10
相关论文
共 50 条
  • [41] BLOOD-GLUCOSE SENSORS - AN OVERVIEW
    PEURA, RA
    MENDELSON, Y
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (08) : 582 - 582
  • [42] Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors
    L. Heinemann
    G. Schmelzeisen-Redeker
    Diabetologia, 1998, 41 : 848 - 854
  • [43] Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors
    Heinemann, L
    Schmelzeisen-Redeker, G
    DIABETOLOGIA, 1998, 41 (07) : 848 - 854
  • [44] A Critical Overview of Sensors for Monitoring Polymerizations
    Fonseca, Gabriela E.
    Dube, Marc A.
    Penlidis, Alexander
    MACROMOLECULAR REACTION ENGINEERING, 2009, 3 (07) : 327 - 373
  • [45] Overview of sensors and needs for environmental monitoring
    Ho, CK
    Robinson, A
    Miller, DR
    Davis, MJ
    SENSORS, 2005, 5 (1-2) : 4 - 37
  • [46] Continuous glucose monitoring using wearable non-enzymatic sensors in a physiological environment
    Abbasnia Tehrani M.
    Ahmadi S.H.
    Alimohammadi S.
    Sasanpour P.
    Batvani N.
    Kazemi S.H.
    Kiani M.A.
    Biosensors and Bioelectronics: X, 2024, 18
  • [47] Comparison of three continuous glucose monitoring systems with six sensors per subject in parallel
    Link, M.
    Freckmann, G.
    Pleus, S.
    Zschornack, E.
    Haug, C.
    Kloetzer, H. -M.
    Ramstetter, E.
    Schmidt, W.
    Schoemaker, M.
    DIABETOLOGIA, 2012, 55 : S428 - S428
  • [48] Laboratory Protocol and Pilot Results for Dynamic Interference Testing of Continuous Glucose Monitoring Sensors
    Pfuetzner, Andreas
    Jensch, Hendrick
    Cardinal, Christopher
    Srikanthamoorthy, Geetham
    Riehn, Eric
    Thome, Nicole
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (01): : 59 - 65
  • [49] Minimizing Adverse Skin Reactions to Wearable Continuous Glucose Monitoring Sensors in Patients With Diabetes
    Seibold, Alexander
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (03): : 713 - 714
  • [50] A contact lens with integrated telecommunication circuit and sensors for wireless and continuous tear glucose monitoring
    Yao, H.
    Liao, Y.
    Lingley, A. R.
    Afanasiev, A.
    Lahdesmaki, I.
    Otis, B. P.
    Parviz, B. A.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2012, 22 (07)