SGRT-based stereotactic body radiotherapy for lung cancer setup accuracy and margin of the PTV

被引:3
|
作者
Guo, Hai-Liang [1 ]
Wu, Wei-Wei [2 ]
Huan, Yan [3 ]
Zhang, Huai-Wen [4 ,5 ]
机构
[1] Gannan Med Univ, Affiliated Hosp 1, Dept Oncol, Ganzhou, Peoples R China
[2] Gannan Med Univ, Affiliated Canc Hosp, GanZhou Canc Hosp, Dept Radiotherapy, Ganzhou, Peoples R China
[3] Peoples Hosp Qianxinan Buyi & Miao Minor Autonomou, Dept Oncol, Qian Xinan, Peoples R China
[4] Nanchang Med Coll, Affiliated Hosp 2, NHC Key Lab Personalized Diag & Treatment Nasophar, Dept Radiotherapy,Jiangxi Canc Hosp, Nanchang 330029, Peoples R China
[5] Third Peoples Hosp Jingdezhen, Dept Oncol, Jingdezhen, Peoples R China
来源
关键词
intrafraction error; lung cancer; stereotactic radiotherapy; surface-guided radiation therapy; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; LOCALIZATION; SYSTEMS; SBRT;
D O I
10.1002/acm2.14195
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Surface-guided radiation therapy (SGRT, AlignRT) was used to analyze motion during stereotactic body radiotherapy (SBRT) in lung cancer patients and to explore the margin of the planning target volume (PTV).Methods: The residual errors of the AlignRT were evaluated based on grayscale cone-beam computed tomography registration results before each treatment. AlignRT log file was used to analyze the correlation between the frequency and longest duration of errors larger than 2 mm and lasting longer than 2 s and maximum error with age and treatment duration. The displacement value at the end of treatment, the average displacement value, and the 95% probability density displacement interval were defined as intrafraction errors, and PTV1, PTV2, PTV3 were calculated by Van Herk formula or Z score analysis. Organ dosimetric differences were compared after the experience-based margin was replaced with PTV3.Results: The interfraction residual errors were Vrt(0), 0.06 +/- 0.18 cm; Lng(0), -0.03 +/- 0.19 cm; Lat(0), 0.02 +/- 0.15 cm; Pitch(0), 0.23 +/- 0.7 degrees; Roll(0), 0.1 +/- 0.69 degrees; Rtn(0), -0.02 +/- 0.79 degrees. The frequency, longest duration and maximum error in vertical direction were correlated with treatment duration (r = 0.404, 0.353, 0.283, p < 0.05, respectively). In the longitudinal direction, the frequency was correlated with age and treatment duration (r = 0.376, 0.283, p < 0.05, respectively), maximum error was correlated with age (r = 0.4, P < 0.05). Vertical, longitudinal, lateral margins of PTV1, PTV2, PTV3 were 2 mm, 4 mm, 2 mm; 2 mm, 2 mm, 2 mm, 3 mm, 5 mm, 3 mm, respectively. After replacing the original PTV, mean lung dose (MLD), 2-cm(3) chest wall dose (CD), lung V-20 decreased by 0.2 Gy, 2.1 Gy, 0.5%, respectively (p < 0.05).Conclusion: AlignRT can be used for interfraction setup and monitoring intrafraction motion. It is more reasonable to use upper and lower limits of the 95% probability density interval as an intrafraction error.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Stereotactic body radiotherapy for adrenal oligometastasis in lung cancer patients
    Arcidiacono, Fabio
    Aristei, Cynthia
    Marchionni, Alessandro
    Italiani, Marco
    Fulcheri, Cristian Paolo Luca
    Saldi, Simonetta
    Casale, Michelina
    Ingrosso, Gianluca
    Anselmo, Paola
    Maranzano, Ernesto
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1115):
  • [42] Surgery versus stereotactic body radiotherapy for resectable lung cancer
    Jimenez M.F.
    Novoa N.M.
    Varela G.
    Current Surgery Reports, 4 (11)
  • [43] Stereotactic body radiotherapy (SBRT) for Stage I lung cancer
    Nagata, Yasushi
    Kimura, Tomoki
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2018, 48 (05) : 405 - 409
  • [44] Stereotactic body radiotherapy for adrenal metastases from lung cancer
    Guiou, Michael
    Mayr, Nina A.
    Kim, Edward Y.
    Williams, Terence
    Lo, Simon S.
    JOURNAL OF RADIATION ONCOLOGY, 2012, 1 (02) : 155 - 163
  • [45] Individual Target Margin for Stereotactic Body Radiation Therapy of Lung Cancer
    Zheng, B.
    Di, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S839 - S840
  • [46] Mid-ventilation based PTV margins in Stereotactic Body Radiotherapy (SBRT): A clinical evaluation
    Peulen, Heike
    Belderbos, Jose
    Rossi, Maddalena
    Sonke, Jan-Jakob
    RADIOTHERAPY AND ONCOLOGY, 2014, 110 (03) : 511 - 516
  • [47] Phantom Study of Cone Beam Computed Tomography Setup Accuracy in Stereotactic Body Radiation Therapy for Lung Cancer Treatment
    Huang, L.
    Papiez, L.
    Papiez, E.
    Solberg, T.
    Timmerman, R.
    MEDICAL PHYSICS, 2010, 37 (06) : 3092 - +
  • [48] Lung reirradiation with stereotactic body radiotherapy
    Maranzano, Ernesto
    Draghini, Lorena
    Anselmo, Paola
    Casale, Michelina
    Arcidiacono, Fabio
    Chirico, Luigia
    Italiani, Marco
    Trippa, Fabio
    JOURNAL OF RADIOSURGERY AND SBRT, 2016, 4 (01): : 61 - 68
  • [49] PTV margin required for radiotherapy of prostate cancer on an MR linac
    Christiansen, R. L.
    Dysager, L.
    Hansen, O.
    Brink, C.
    Bernchou, U.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1284 - S1284
  • [50] Factors affecting bony anatomy setup errors for lung Stereotactic Ablative Body Radiotherapy (SABR)
    Quinn, Emily
    Bennett, Erica
    Barry, Laura
    England, Andrew
    Devine, Annemarie
    McEntee, Mark
    O'Donovan, Theresa
    Kelly, Paul
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S5613 - S5615