Modelling the response of a CsI(Tl)-PiN photodiode Microscintillator detector

被引:0
|
作者
Tabbett, Justin [1 ]
Aplin, Karen L. [1 ]
机构
[1] Univ Bristol, Fac Sci & Engn, Queens Bldg,Univ Walk, Bristol BS8 1TR, England
关键词
Radioactivity detector; Ionisation; Scintillator; PiN photodiode; Simulation; LTspice; LIGHT; DEPENDENCE;
D O I
10.1016/j.nima.2024.169105
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The full instrument response of a superminiaturised CsI(Tl)-PiN photodiode radioactivity detector, intended for deployment on a meteorological radiosonde, has been modelled by combining a physics-based model of the sensor with the detector circuit response, obtained via an LTspice simulation. The model uses the incident energy of a gamma ray as an input, and produces the pulse expected from the detector. The detector response was verified by comparing the simulated energy calibration with a laboratory source. The measurement circuit is found to control the minimum detectable energy of 26 keV, and the maximum detectable energy is similar to 10 MeV. The energy sensitivity of the PiN detector is 0.29 +/- 0.02 mV/keV in the 0-800 keV range. The simulation and laboratory calibrations were consistent to better than 5% over the calibration range of the instrument.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Pulse shape analysis of signals from a CsI(Tl)/photodiode detector
    Bird, A.J.
    Carter, T.
    He, Z.
    Dean, A.J.
    Ramsden, D.
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1995, 353 (1-3):
  • [12] Nuclear counter effect of silicon PIN photodiode used in CsI(Tl) calorimeter
    Satpathy, A
    Tamai, K
    Fukushima, M
    Kim, DY
    Lee, MH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 391 (03): : 423 - 426
  • [13] Noise contributions to energy resolution in CsI(Tl) scintillation detector with PIN photodiode readout (vol 463, pg 288, 2001)
    Mikhailov, MA
    Panteleev, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 483 (03): : 833 - 833
  • [14] PULSE-SHAPE ANALYSIS OF SIGNALS FROM A CSI(TL) PHOTODIODE DETECTOR
    BIRD, AJ
    CARTER, T
    HE, Z
    DEAN, AJ
    RAMSDEN, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 46 - 49
  • [15] CsI(Tl)-pin detector as an element of a charged particle multiplicity filter array
    Bandyopadhyay, D
    Basu, SK
    RADIATION PHYSICS AND CHEMISTRY, 1998, 51 (4-6) : 457 - 458
  • [16] CsI(Tl)-pin detector as an element of a charged particle multiplicity filter array
    VEC Cent, Calcutta, India
    Radiat Phys Chem, 4-6 (457-458):
  • [17] Performance of Indigenously Developed CsI(Tl)-Photodiode Detector for Gamma-ray Spectroscopy
    Singh, S. G.
    Singh, Arvind
    Topkar, Anita
    Gadkari, S. C.
    SOLID STATE PHYSICS: PROCEEDINGS OF THE 55TH DAE SOLID STATE PHYSICS SYMPOSIUM 2010, PTS A AND B, 2011, 1349 : 481 - +
  • [18] CsI(Tl)-photodiode detectors for γ-ray spectroscopy
    Fioretto, E
    Innocenti, F
    Viesti, G
    Cinausero, M
    Zuin, L
    Fabris, D
    Lunardon, M
    Nebbia, G
    Prete, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3): : 412 - 416
  • [19] CsI(Tl)-photodiode detectors for γ-ray spectroscopy
    Fioretto, E
    Innocenti, F
    Viesti, G
    Cinausero, M
    Zuin, L
    Fabris, D
    Lunardon, M
    Nebbia, G
    Prete, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1315 - 1318
  • [20] CsI(Tl)-photodiode detectors for γ-ray spectroscopy
    Fioretto, E
    Innocenti, F
    Viesti, G
    Cinausero, M
    Zuin, L
    Fabris, D
    Lunardon, M
    Nebbia, G
    Prete, G
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 106 - 109