Shear connection performance of cold-formed steel and plywood composite flooring systems: Experimental and numerical investigation

被引:5
|
作者
Al-Hunaity, Suleiman A. [1 ]
Karki, Dheeraj [1 ]
Far, Harry [1 ]
机构
[1] Univ Technol Sydney UTS, Fac Engn & Informat Technol, Sch Civil & Environm Engn, Sydney, Australia
关键词
Composite flooring systems; Cold -formed steel; Shear connection performance; Load carrying capacity; Finite element analysis; Composite beams; ANSYS; Steel; Timber; BEHAVIOR; DESIGN; GYPSUM; BEAM;
D O I
10.1016/j.istruc.2023.01.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study carries out numerical and experimental investigation on shear connection performance of flooring systems comprising of cold-formed steel joists and engineered plywood panels. A 3-D finite element model has been developed using ANSYS software which considers the nonlinear behaviour and damage of plywood panels using a maximum stress-based criterion incorporated in the FE model. The yielding behaviour of steel joists and fasteners (screws and bolts) is defined as a multilinear plastic hardening material model defined in ANSYS software. The FE model was validated against the experimental results obtained from push-out tests conducted on specimens utilising different connection arrangements. The validated FE models showed a good agreement with the experimental results of the push-out tests in terms of load-slip behaviour, ultimate peak capacity, and failure modes. Finally, the validated FE models are utilised to perform a parametric study that investigates the effect of varying various parameters, including diameter and yield strength of self-drilling screws, the thickness of plywood panels, value of friction coefficient, and the ratio of fastener diameter to the joist thickness, on the initial stiffness, failure mode and ultimate load capacity of the cold-formed steel and plywood composite connections.
引用
收藏
页码:901 / 917
页数:17
相关论文
共 50 条
  • [41] Study on Shear Performance of Cold-formed Steel Composite Wall with New Type of stud
    Wang, Chungang
    Yue, Sizhe
    Liu, Hong
    Zhang, Zhuangnan
    2017 INTERNATIONAL SYMPOSIUM ON APPLICATION OF MATERIALS SCIENCE AND ENERGY MATERIALS (SAMSE 2017), 2018, 322
  • [42] Finite Element Analyses of Demountable Shear Connection in Cold-Formed Steel-Concrete Composite Beam Based on Experimental Data
    Žuvelek, Vlaho
    Ćurković, Ivan
    Lukačević, Ivan
    Rajić, Andrea
    ce/papers, 2023, 6 (3-4) : 213 - 219
  • [43] Shear Connection Research for Cold-formed Thin-walled Steel and Foam Concrete Composite Member
    Liu, Dianzhong
    Sun, Chao
    Wang, Fayu
    Wu, Qiong
    2016 INTERNATIONAL CONFERENCE ON ARCHITECTURE AND CIVIL ENGINEERING (ICACE 2016), 2016, : 378 - 382
  • [44] Shear connection of reinforcement stiffened cold-formed U-shaped steel and concrete composite beam
    Zhao, Yi
    Yang, Yuanlong
    Xu, Shaoqian
    Liu, Jiepeng
    Chen, Yohchia Frank
    ENGINEERING STRUCTURES, 2020, 219
  • [45] Experimental and numerical study on a full scale apex connection of cold-formed steel portal frames
    Ozturk, Ferhan
    Pul, Selim
    THIN-WALLED STRUCTURES, 2015, 94 : 79 - 88
  • [46] Numerical modelling of rectangular cold-formed steel and composite columns
    Castanheira, Deborah Souza
    Ornelas de Lima, Luciano Rodrigues
    Goncalves da Silva Vellasco, Pedro Colmar
    da Silva, Andre Tenchini
    Rodrigues, Monique Cordeiro
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2019, 172 (11) : 805 - 818
  • [47] Experimental investigation on performance of perforated cold-formed steel tubular stub columns
    Singh, Tekcham Gishan
    Singh, Konjengbam Darunkumar
    THIN-WALLED STRUCTURES, 2018, 131 : 107 - 121
  • [48] Experimental study on mechanical behavior of cold-formed thin-walled steel bamboo plywood composite slabs
    Li, Yu-Shun
    Shan, Wei
    Han, Tian-Shi
    Shen, Huang-Ying
    Zhang, Wang-Li
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2009, 41 (SUPPL. 2): : 101 - 105
  • [49] Numerical study on behavior of bolted shear connector used in composite cold-formed steel beams
    Hosseinpour, Mahmoud
    Zeynalian, Mehran
    Daei, Maryam
    Ataei, Abdoreza
    THIN-WALLED STRUCTURES, 2022, 177
  • [50] Experimental study on axial performance of steel honeycomb sandwich cold-formed steel composite walls
    Wang, Chungang
    Cheng, Tianyu
    Zhang, Zhuangnan
    Liu, Tong
    Feng, Linsheng
    Cheng, Daye
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2024, 45 (11): : 163 - 172