Pouring and Curing for Sample Preparation Technology for the Analysis of the Silicon-Aluminum Ratio of Molecular Sieves by Energy Dispersive X-Ray Fluorescence (EDXRF)

被引:1
|
作者
Shan, Qing [1 ]
Luo, Yangxue [1 ]
Zhang, Xinlei [2 ]
Zhang, Zhanpeng [1 ]
Jia, Wenbao [1 ,5 ]
Ling, Yongsheng [1 ]
Hei, Daqian [3 ]
Zhang, Jiandong [1 ]
Shi, Chao [1 ]
Bao, Jiehua [4 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Dept Nucl Sci & Engn, Coll Mat Sci & Technol, Nanjing, Peoples R China
[2] Hikvis Res Inst, Hangzhou, Peoples R China
[3] Lanzhou Univ, Sch Nucl Sci & Technol, Lanzhou, Peoples R China
[4] Nanjing Inst Technol, Sch Mat Sci & Engn, Nanjing, Jiangsu, Peoples R China
[5] Nanjing Univ Aeronaut & Astronaut, Coll Mat Sci & Engn, Dept Nucl Sci & Technol, 29 Jiangjun Rd, Nanjing 211106, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Curing; energy dispersive X-ray fluorescence (EDXRF); molecular sieves; pouring; silicon-aluminum ratio; SPECTROMETRIC ANALYSIS; ZEOLITES;
D O I
10.1080/00032719.2023.2301045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The silicon-aluminum ratio of the molecular sieves is a crucial control index for the quality of synthetic molecular sieves. Here a fast, simple and reliable sample preparation method, referred to as pouring and curing method, is described for determining the silicon-aluminum ratio of high silicon molecular sieves by energy dispersive x-ray fluorescence (EDXRF). Resin is used as the carrier with the addition of a curing agent, so that the sample powder is embedded in the resin matrix. By measuring sixteen random positions of the same cured sample, the homogeneity of the sample was evaluated to ensure the stability of the results. A double logarithmic calibration curve of the analysis line ratio and the corresponding concentration ratio of silicon and aluminum was established according to the binary ratio method. The results by EDXRF and inductively coupled plasma-optical emission spectrometer (ICP-OES) were compared with a relative standard error from 2.934 to 6.777%. The good precision shows that the pouring and curing method is a suitable for measuring the silicon-aluminum ratio of molecular sieves.
引用
收藏
页码:2694 / 2703
页数:10
相关论文
共 50 条
  • [41] Gaseous detectors for energy dispersive X-ray fluorescence analysis
    Veloso, J. F. C. A.
    Silva, A. L. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 24 - 39
  • [42] Determination of multi-element profiles of soil using energy dispersive X-ray fluorescence (EDXRF)
    Yu, KN
    Yeung, ZLL
    Lee, LYL
    Stokes, MJ
    Kwok, RCW
    APPLIED RADIATION AND ISOTOPES, 2002, 57 (02) : 279 - 284
  • [43] Levels of trace elements of few Indian spices by energy dispersive X-ray fluorescence (EDXRF) method
    Joseph, D
    Lal, M
    Bajpai, HN
    Mathur, PK
    JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 1999, 36 (03): : 264 - 265
  • [44] Levels of trace elements of few Indian spices by Energy Dispersive X-ray Fluorescence (EDXRF) method
    Joseph, Daisy
    Lal, M.
    Bajpai, H.N.
    Mathur, P.K.
    Journal of Food Science and Technology, 36 (03): : 264 - 265
  • [45] Effect of sample preparation procedure on standardless wavelength dispersive X-ray fluorescence analysis of plant samples
    Orlic, Jovana
    Grzetic, Ivan
    Ilijevic, Konstantin
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 184
  • [46] Sample preparation of solid materials for X-ray fluorescence analysis
    不详
    SPECTROSCOPY, 2007, : 12 - 12
  • [47] SAMPLE PREPARATION AND X-RAY FLUORESCENCE ANALYSIS OF SULFIDE ORES
    Ling, Ming-Xing
    Liu, Ying
    Zhang, Hong
    Sun, Weidong
    ANALYTICAL LETTERS, 2014, 47 (09) : 1598 - 1605
  • [48] X-ray fluorescence analysis: Investigation of microdroplet sample preparation
    Kawauchi, A
    Ishida, M
    Saitoh, I
    SPECTROSCOPY LETTERS, 1996, 29 (06) : 979 - 993
  • [49] Use of Preconcentration for Sample Preparation in X-ray Fluorescence Analysis
    E. N. Maiorova
    Journal of Analytical Chemistry, 2003, 58 (7) : 637 - 638
  • [50] Solid sample preparation for X-ray fluorescence analysis: a review
    Diaz, Linda Alejandra Perez
    Saiz, Juliana Serna
    Quezada, Henry Torres
    REVISTA COLOMBIANA DE QUIMICA, 2023, 52 (03): : 21 - 40