A Rare Case of Cochlear Implant Electrode Array Misplacement Into the Posterior Semicircular Canal

被引:0
|
作者
Zhao, Christopher H. [1 ]
Quimby, Alexandra E. [2 ]
Bigelow, Douglas C. [2 ]
机构
[1] Rowan Univ, Cooper Med Sch, 401 South Broadway, Camden, NJ 08103 USA
[2] Univ Penn, Dept Otorhinolaryngol Head & Neck Surg, Philadelphia, PA 19104 USA
来源
LARYNGOSCOPE | 2023年 / 133卷 / 01期
关键词
cochlear implant; cochleostomy; electrode array misplacement; posterior semicircular canal;
D O I
10.1002/lary.30338
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Cochlear implant electrode array misplacement is a rare but serious complication that may result in failure of hearing rehabilitation, non-auditory percepts, vestibular disturbance, or damage to adjacent neurovascular structures. We present a case of an elderly patient who suffered electrode array misplacement into the posterior semicircular canal, resulting in vestibular symptoms and severe downstream sequelae. The risk of misplacement may be higher in patients with a history of chronic otitis media or prior otologic surgery, and with the use of pre-curved electrode arrays. Electrophysiological testing and intraoperative imaging may allow for early detection and intervention in these cases. Laryngoscope, 2022
引用
收藏
页码:175 / 177
页数:3
相关论文
共 50 条
  • [21] Determining optimal cochlear implant electrode array with OTOPLAN
    Yoshimura, Hidekane
    Watanabe, Kizuki
    Nishio, Shin-ya
    Takumi, Yutaka
    Usami, Shin-ichi
    ACTA OTO-LARYNGOLOGICA, 2023, 143 (09) : 748 - 752
  • [22] Cochlear Implant Electrode Array Design and Speech Understanding
    Vohra, Varun
    Andresen, Nicholas S.
    Carver, Courtney
    Dunham, Rachel
    Marsiglia, Dawn
    Yeagle, Jenifer
    Della Santina, Charles C.
    Creighton Jr, Francis X.
    Bowditch, Stephen P.
    Sun, Daniel Q.
    OTOLOGY & NEUROTOLOGY, 2024, 45 (02) : 136 - 142
  • [23] Radiology Quiz Case 2 Posterior semicircular canal dehiscence
    De Diego, Beatriz
    Trinidad, Almudena
    Ramon Garcia-Berrocal, Jose
    Ramirez-Camacho, Rafael
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2011, 137 (04) : 405 - +
  • [24] Posterior Semicircular Canal Dehiscence: First Reported Case Series
    Gopen, Quinton
    Zhou, Guangwei
    Poe, Dennis
    Kenna, Margaret
    Jones, Dwight
    OTOLOGY & NEUROTOLOGY, 2010, 31 (02) : 339 - 344
  • [25] Posterior Semicircular Canal Dehiscence: Case Series and Systematic Review
    Lee, Joshua A.
    Liu, Yuan F.
    Nguyen, Shaun A.
    McRackan, Theodore R.
    Meyer, Ted A.
    Rizk, Habib G.
    OTOLOGY & NEUROTOLOGY, 2020, 41 (04) : 511 - 521
  • [26] Electrode Misdirection into the Superior Semicircular Canal: Complication of Cochlear Implantation by Round Window Approach
    Kim, Minbum
    Yang, Won Sun
    Jeon, Ju Hyun
    Choi, Jae Young
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2014, 10 (03): : 246 - 250
  • [27] A COMPLEX CASE OF COCHLEAR IMPLANT ELECTRODE PLACEMENT
    LEVINE, SC
    AMERICAN JOURNAL OF OTOLOGY, 1989, 10 (06): : 477 - 480
  • [28] Insertion trauma of a cochlear implant electrode array with Nitinol inlay
    Rau, Thomas S.
    Harbach, Lenka
    Pawsey, Nick
    Kluge, Marcel
    Erfurt, Peter
    Lenarz, Thomas
    Majdani, Omid
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (11) : 3573 - 3585
  • [29] Determination of the curling behavior of a preformed cochlear implant electrode array
    Thomas S. Rau
    Omid Majdani
    Andreas Hussong
    Thomas Lenarz
    Martin Leinung
    International Journal of Computer Assisted Radiology and Surgery, 2011, 6 : 421 - 433
  • [30] Fixation of the electrode array with bone pate in cochlear implant surgery
    Gstoettner, WK
    Hamzavi, J
    Baumgartner, WD
    Czerny, CC
    ACTA OTO-LARYNGOLOGICA, 2000, 120 (03) : 369 - 374