Factors that contribute to false-negative results in CT-guided transthoracic lung core-needle biopsy

被引:4
|
作者
Sun, Daqian [1 ]
Yao, Tianxiao [1 ]
Wang, Lixin [2 ]
Ma, Shengmei [1 ]
Gao, Min [2 ]
Li, Jingshuo [1 ]
Li, Chunhai [1 ]
Xu, Lisheng [3 ,4 ]
机构
[1] Shandong Univ, Qilu Hosp, Dept Radiol, Jinan, Peoples R China
[2] Shandong Univ, Sch Nursing & Rehabil, Jinan, Peoples R China
[3] Shandong Univ, Qilu Hosp, Dept Pulm & Crit Care Med, Jinan, Peoples R China
[4] Shandong Univ, Qilu Hosp, Jinan, Peoples R China
关键词
False-negative results; non-specific benign; risk factors; COMPUTED-TOMOGRAPHY; PULMONARY-LESIONS; CANCER; EXPERIENCE; ASPIRATION; NODULES; BENIGN; MODEL; TRUE;
D O I
10.4103/jcrt.jcrt_2054_22
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: To investigate the possibility of false-negative occurrence of non-specific benign pathological results on CT-guided transthoracic lung core-needle biopsy and identify risk factors for false-negative results.Methods: The clinical, imaging, and surgical data of 403 lung biopsy patients were retrospectively analyzed. Patients were divided into true-negative and false-negative (FN) groups according to the final diagnosis. Univariate analysis was used to compare the variables in two groups for statistical differences, and multivariate analysis was used to clarify the risk factors associated with FN results.Results: Of the 403 lesions, 332 were finally confirmed as benign and 71 to be malignant, with a FN rate of 17.6%. Older patient age (P = 0.01), burr sign (P = 0.00), and pleural traction sign (P = 0.02) were independent risk factors for FN results. The area under the receiver operating characteristic (ROC) curve's area under curve (AUC) was 0.73.Conclusion: CT-guided transthoracic lung core-needle biopsy has a high diagnostic accuracy and low rate of FN results. Older patient age, the burr sign, and the pleural traction sign are independent risk factors for FN results that should be monitored prior to surgery to reduce the risk of FN results.
引用
收藏
页码:86 / 91
页数:6
相关论文
共 50 条
  • [31] Value of CT-guided core-needle biopsy in diagnosis and classification of malignant lymphomas using automated biopsy gun
    Li, Li
    Wu, Qiu-Liang
    Liu, Li-Zhi
    Mo, Yun-Xian
    Xie, Chuan-Miao
    Zheng, Lie
    Chen, Lin
    Wu, Pei-Hong
    WORLD JOURNAL OF GASTROENTEROLOGY, 2005, 11 (31) : 4843 - 4847
  • [32] Radiographic and Clinical Characterization of False Negative Results from CT-Guided Needle Biopsies of Lung Nodules
    Gelbman, Brian D.
    Cham, Mathew D.
    Kim, Won
    Libby, Daniel M.
    Smith, James P.
    Port, Jeffrey L.
    Altorki, Nasser K.
    Henschke, Claudia I.
    Yankelevitz, David F.
    JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (05) : 815 - 820
  • [33] CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy
    Jeon, Min-Cheol
    Kim, Ju Ock
    Jung, Sung Soo
    Park, Hee Sun
    Lee, Jeong Eun
    Moon, Jae Young
    Chung, Chae Uk
    Kang, Da Hyun
    Park, Dong Il
    TUBERCULOSIS AND RESPIRATORY DISEASES, 2018, 81 (04) : 330 - 338
  • [34] Adequacy of CT-guided Lung Core Biopsy with and without Fine Needle Aspiration
    Rivera-Galvis, Lidys
    Zhang, Yong
    Abendroth, Catherine
    LABORATORY INVESTIGATION, 2024, 104 (03) : S461 - S462
  • [35] Analysis of false-negative results after US-guided 14-gauge core needle breast biopsy
    Ji Hyun Youk
    Eun-Kyung Kim
    Min Jung Kim
    Jin Young Kwak
    Eun Ju Son
    European Radiology, 2010, 20 : 782 - 789
  • [36] CT-guided Transthoracic Core-Needle Biopsies of Mediastinal and Lung Lesions in 235 Consecutive Patients: Factors Affecting the Risks of Complications and Occurrence of a Final Diagnosis of Malignancy
    Cesar, Daniel Nicoletti
    Torres, Ulysses S.
    D'Ippolito, Giuseppe
    Souza, Arthur Soares
    ARCHIVOS DE BRONCONEUMOLOGIA, 2019, 55 (06): : 297 - 305
  • [37] Analysis of false-negative results after US-guided 14-gauge core needle breast biopsy
    Youk, Ji Hyun
    Kim, Eun-Kyung
    Kim, Min Jung
    Kwak, Jin Young
    Son, Eun Ju
    EUROPEAN RADIOLOGY, 2010, 20 (04) : 782 - 789
  • [38] Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules
    Nicola Rotolo
    Chiara Floridi
    Andrea Imperatori
    Federico Fontana
    Anna Maria Ierardi
    Monica Mangini
    Veronica Arlant
    Giuseppe De Marchi
    Raffaele Novario
    Lorenzo Dominioni
    Carlo Fugazzola
    Gianpaolo Carrafiello
    European Radiology, 2016, 26 : 381 - 389
  • [39] Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules
    Rotolo, Nicola
    Floridi, Chiara
    Imperatori, Andrea
    Fontana, Federico
    Ierardi, Anna Maria
    Mangini, Monica
    Arlant, Veronica
    De Marchi, Giuseppe
    Novario, Raffaele
    Dominioni, Lorenzo
    Fugazzola, Carlo
    Carrafiello, Gianpaolo
    EUROPEAN RADIOLOGY, 2016, 26 (02) : 381 - 389
  • [40] Initial Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy of Lung Lesions Performed by a Pulmonologist
    Ahn, June Hong
    Jang, Jong Geol
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (06)