Research on the localization of pipe burst based on transient flow in a water supply network

被引:0
|
作者
Zheng, Guolei [1 ,2 ]
Tian, Yimei [1 ,4 ]
Li, Zhengxuan [1 ]
Cheng, Jing [1 ]
Liang, Jianwen [3 ]
Peng, Sen [1 ,4 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin, Peoples R China
[2] Univ Sci & Technol China, Sch Earth & Space Sci, Hefei, Peoples R China
[3] Tianjin Univ, Sch Civil Engn, Tianjin, Peoples R China
[4] Tianjin Univ, Sch Environm Sci & Engn, 135 Yaguan Rd, Haihe Educ Pk, Tianjin 300350, Peoples R China
基金
国家重点研发计划;
关键词
Water supply network; system abnormity; transient flow; pipe burst localization; abnormal features of water pressure; NATURAL-GAS PIPELINES; LEAK DETECTION; LOCATION; SYSTEMS; SINGLE; FRICTION; DESIGN; MODEL;
D O I
10.1177/14759217231209405
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Methods for determining pipe burst (PB) locations based on supervisory control and data acquisition systems (SCADAs) have been widely studied. Existing location methods either only detect PB areas or are only applied to relatively simple pipe networks. Thus, it is necessary to develop a PB localization method that can both accurately locate the PB and be used for complex pipe networks. Accordingly, in this study, a complex experimental pipe network with a high-frequency SCADA was built, and PB events were constructed under different conditions. After they were analyzed, the water pressure and flow anomalous features of the PBs were summarized. According to the propagation laws and damping theories of transient flow (TF), a PB localization method, that is, the TF simulation (TFS) method, was first proposed and developed after a TF model of the experimental pipe network was established. Using this method, two PB events were recognized, the burst pipes were identified, and the PBs were accurately located. Compared with the negative pressure wave method, the TFS method exhibits a higher location accuracy and a wider applicability to pipe networks. Through error analyses, it is shown that the TFS method has small errors. To reduce cost, the sampling frequency was decreased to 50 Hz, that is, the minimum required sampling frequency for this study, and under this condition, PB localization was successfully realized. An additional three PB localizations illustrate that they have acceptable errors and that the TFS method has good repeatability.
引用
收藏
页码:2679 / 2697
页数:19
相关论文
共 50 条
  • [1] Research on the optimization of supply water pipe network
    He, Zhang
    Hui, Zhang Xiao
    Guo, Cui Jian
    PROGRESS IN ENVIRONMENTAL PROTECTION AND PROCESSING OF RESOURCE, PTS 1-4, 2013, 295-298 : 1876 - +
  • [2] Burst Analysis of Water Supply Pipe Based on Hydrodynamic Simulation
    Wang Pengfei
    Jiang Zhiqiang
    Duan Jiefeng
    Water Resources Management, 2023, 37 : 2161 - 2179
  • [3] Burst Analysis of Water Supply Pipe Based on Hydrodynamic Simulation
    Wang, Pengfei
    Jiang, Zhiqiang
    Duan, Jiefeng
    WATER RESOURCES MANAGEMENT, 2023, 37 (05) : 2161 - 2179
  • [4] On the transient flow behavior in pressurized plastic pipe-based water supply systems
    Essaidi, Badreddine
    Triki, Ali
    AQUA-WATER INFRASTRUCTURE ECOSYSTEMS AND SOCIETY, 2021, 70 (01) : 67 - 76
  • [5] Research on Inverse Transient Leakage Location of Water Supply Network Based on Genetic Algorithm
    Fei Jiangang
    Dong Shen
    Lv Mou
    Sheng Zebin
    ADVANCES IN HYDROLOGY AND HYDRAULIC ENGINEERING, PTS 1 AND 2, 2012, 212-213 : 679 - +
  • [6] Research of Evaluation and Maintenance Decision Model about Urban Water Supply Pipe Burst Hidden Trouble Based on GIS
    Ren, Yongchang
    Xing, Tao
    Quan, Qiang
    Zhao, Ying
    PROCEEDINGS OF ISCRAM CHINA 2010: FOURTH INTERNATIONAL CONFERENCE ON INFORMATION SYSTEMS FOR CRISIS RESPONSE AND MANAGEMENT, 2010, : 494 - 501
  • [7] Pipe Burst Risk State Assessment and Classification Based on Water Hammer Analysis for Water Supply Networks
    Wang, Ronghe
    Wang, Zhixun
    Wang, Xiaoxue
    Yang, Haibo
    Sun, Jilong
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2014, 140 (06)
  • [8] Leak localization of water supply network based on temporal convolutional network
    Zhang, Jie
    Yang, Xiaoping
    Li, Juan
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (12)
  • [9] Research on Failure Pressure Prediction of Water Supply Pipe Based on GA-BP Neural Network
    Li, Qingfu
    Li, Zeyi
    WATER, 2024, 16 (18)
  • [10] Using hydraulic model research for the modification of the water supply pipe network optimization
    Jiang, Baiyi
    Jian, Wenyu
    Zhang, Rui
    ADVANCES IN ENERGY SCIENCE AND EQUIPMENT ENGINEERING, 2015, : 75 - 79