Influence of ionization volume and sample gas flow rate on separation power in gas chromatography-ion mobility spectrometry

被引:0
|
作者
Kobelt, Tim [1 ]
Lippmann, Martin [1 ]
Wuttke, Jannik [1 ]
Wessel, Hanno [1 ]
Zimmermann, Stefan [1 ]
机构
[1] Leibniz Univ Hannover, Inst Elect Engn & Measurement Technol, Dept Sensors & Measurement Technol, Appelstr 9A, D-30167 Hannover, Germany
关键词
GC-IMS; Peak broadening; Ionization volume; Effective detector volume; QUANTITATIVE-ANALYSIS; TOLUENE; EXPLOSIVES; EFFICIENCY; DETECTORS; DIFFUSION; BENZENE; XYLENE;
D O I
10.1016/j.chroma.2023.464506
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, the influence of the sample gas flow rate and the ionization region volume of an ion mobility spectrometer (IMS) used as a detector in gas chromatography (GC) on GC-IMS peak shape has been investigated. Therefore, a drift tube IMS with a field-switching ion shutter, a defined ionization region volume and an ultraviolet radiation source was used. To identify the influence of the sample gas flow rate entering the ionization region (equals the GC carrier gas flow rate if no further make-up gas is used) and the ionization region volume on peak broadening and signal intensity, different sample volumes as they would elute from a GC were tested at a variety of sample gas flow rates at a given ionization region volume. The results clearly show that for low sample gas flow rates a depletion of sample molecules in the ionization region leads to a significant decrease in effective detector volume but also to reduced signal intensities. Therefore, for optimal performance of a GC-IMS, the optimal operating point of the GC should match the flow range, where the IMS provides the best compromise between signal-to-noise ratio and peak broadening.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Sweat-based stress screening with gas chromatography-ion mobility spectrometry and electronic nose
    Tungkijanansin, Nuttanee
    Sirinara, Patthrarawalai
    Tunvirachaisakul, Chavit
    Srikam, Saran
    Kittiban, Kasinee
    Thongthip, Siriwan
    Kerdcharoen, Teerakiat
    Maes, Michael
    Kulsing, Chadin
    ANALYTICA CHIMICA ACTA, 2024, 1320
  • [32] Identification of terpenes and essential oils by means of static headspace gas chromatography-ion mobility spectrometry
    Rodriguez-Maecker, Roman
    Vyhmeister, Eduardo
    Meisen, Stefan
    Rosales Martinez, Antonio
    Kuklya, Andriy
    Telgheder, Ursula
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (28) : 6595 - 6603
  • [33] Adulteration detection of essence in sesame oil based on headspace gas chromatography-ion mobility spectrometry
    Dou, Xinjing
    Zhang, Liangxiao
    Yang, Ruinan
    Wang, Xiao
    Yu, Li
    Yue, Xiaofeng
    Ma, Fei
    Mao, Jin
    Wang, Xiupin
    Li, Peiwu
    FOOD CHEMISTRY, 2022, 370
  • [34] Identification of Characteristic Odorants in Duck Meat by Headspace-Gas Chromatography-Ion Mobility Spectrometry
    Zhao G.
    Wang S.
    Zhu C.
    Sun L.
    Wang Z.
    Wang X.
    Xie W.
    Shipin Kexue/Food Science, 2023, 44 (04): : 247 - 255
  • [35] Ion mobility spectrometry detection for gas chromatography
    Kanu, Abu B.
    Hill, Herbert H., Jr.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1177 (01) : 12 - 27
  • [36] Coupling Gas Chromatography with Ion Mobility Spectrometry
    Witkiewicz, Zygfryd
    Perycz, Urszula
    Maziejuk, Miroslaw
    Puton, Jaroslaw
    LCGC EUROPE, 2016, 29 (06) : 294 - 303
  • [37] The novel use of gas chromatography-ion mobility-time of flight mass spectrometry with secondary electrospray ionization for complex mixture analysis
    Crawford, Christina L.
    Graf, Stephan
    Gonin, Marc
    Fuhrer, Katrin
    Zhang, Xing
    Hill, Herbert H., Jr.
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2011, 14 (01) : 23 - 30
  • [38] Effect of Different Fermentation Methods on Aroma Composition of Yellow Peach Wine Analyzed by Gas Chromatography-Mass Spectrometry and Gas Chromatography-Ion Mobility Spectrometry
    Ma N.
    Yao L.
    Sun M.
    Wang H.
    Song S.
    Chang X.
    Feng T.
    Shipin Kexue/Food Science, 2023, 44 (12): : 306 - 314
  • [39] Closed tube sample introduction for gas chromatography-ion mobility spectrometry analysis of water contaminated with a chemical warfare agent surrogate compound
    Erickson, RP
    Tripathi, A
    Maswadeh, WM
    Snyder, AP
    Smith, PA
    ANALYTICA CHIMICA ACTA, 2006, 556 (02) : 455 - 461
  • [40] Gas Chromatography-Ion Mobility Spectrometry Detection of Odor Fingerprint as Markers of Rapeseed Oil Refined Grade
    Chen, Tong
    Qi, Xingpu
    Chen, Mingjie
    Chen, Bin
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2019, 2019