Population-based reference values for 4D flow MRI derived aortic blood flow parameters

被引:7
|
作者
Schafstedde, Marie [1 ,2 ,3 ,4 ]
Jarmatz, Lina [1 ]
Bruening, Jan [1 ,4 ]
Huellebrand, Markus [1 ,5 ]
Nordmeyer, Sarah [1 ,2 ]
Harloff, Andreas [6 ,7 ]
Hennemuth, Anja [1 ,4 ,5 ]
机构
[1] German Heart Ctr Charite, Inst Congenital Heart Dis, Berlin, Germany
[2] German Heart Ctr Charite, Dept Congenital Heart Dis, Berlin, Germany
[3] Berlin Inst Hlth, Berlin, Germany
[4] German Ctr Cardiovasc Res, Partner Site Berlin, DZHK, Berlin, Germany
[5] Fraunhofer MEVIS, Bremen, Germany
[6] Univ Med Ctr Freiburg, Dept Neurol, Freiburg, Germany
[7] Univ Freiburg, Fac Med, Freiburg, Germany
关键词
population; 4D flow MRI; cardiovascular magnetic resonance; aorta; blood flow; hemodynamics; reference values; WALL SHEAR-STRESS; PULSE-WAVE VELOCITY; THORACIC AORTA; VALVE; PATTERNS; QUANTIFICATION; AGE; MORPHOLOGY; STIFFNESS;
D O I
10.1088/1361-6579/acb8fd
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. This study assesses age-related differences of thoracic aorta blood flow profiles and provides age- and sex-specific reference values using 4D flow cardiovascular magnetic resonance (CMR) data. Approach. 126 volunteers (age 20-80 years, female 51%) underwent 4D flow CMR and 12 perpendicular analysis planes in the thoracic aorta were specified. For these planes the following parameters were evaluated: body surface area-adjusted aortic area (A '), normalized flow displacement (NFD), the degree of wall parallelism (WPD), the minimal relative cross-sectional area through which 80% of the volume flow passes (A80) and the angle between flow direction and centerline (alpha). Main results. Age-related differences in blood flow parameters were seen in the ascending aorta with higher values for NFD and angle and lower values for WPD and A80 in older subjects. All parameters describing blood flow patterns correlated with the cross-sectional area in the ascending aorta. No relevant sex-differences regarding blood flow profiles were found. Significance. These age- and sex-specific reference values for quantitative parameters describing blood flow within the aorta might help to study the clinical relevance of flow profiles in the future.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Visual 4D MRI Blood Flow Analysis with Line Predicates
    Born, Silvia
    Pfeifle, Matthias
    Markl, Michael
    Scheuermann, Gerik
    IEEE PACIFIC VISUALIZATION SYMPOSIUM 2012, 2012, : 105 - 112
  • [32] Hemodynamics of Acute Type B Aortic Dissections with 4D Flow MRI
    Cebull, Hannah
    Naeem, Muhammad
    Liu, Minliang
    Dong, Hai
    Gleason, Rudolph
    Elefteriades, John
    Piccinelli, Marina
    Oshinski, John
    Leshnower, Bradley
    CIRCULATION, 2024, 150
  • [33] Assessment of Cerebral Blood Flow Pulsatility and Cerebral Arterial Compliance With 4D Flow MRI
    Holmgren, Madelene
    Wahlin, Anders
    Dunas, Tora
    MaIm, Jan
    Eklund, Anders
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (05) : 1516 - 1525
  • [34] Editorial for "Evaluating a Phase-Specific Approach to Aortic Flow: A 4D Flow MRI Study"
    Cebull, Hannah L.
    Oshinski, John N.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (03) : 1068 - 1069
  • [35] Visualizing and quantifying flow stasis in abdominal aortic aneurysms in men using 4D flow MRI
    Ziegler, Magnus
    Welander, Martin
    Lantz, Jonas
    Lindenberger, Marcus
    Bjarnegard, Niclas
    Karlsson, Matts
    Ebbers, Tino
    Lanne, Toste
    Dyverfeldt, Petter
    MAGNETIC RESONANCE IMAGING, 2019, 57 : 103 - 110
  • [36] Spiral readouts for 4D flow MRI
    Andreas Sigfridsson
    Sven Petersson
    Carl Johan Carlhall
    Tino Ebbers
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [37] Abdominal Applications of 4D Flow MRI
    Riedel, Christoph
    Lenz, Alexander
    Fischer, Lutz
    Li, Jun
    Piecha, Feilix
    Kluwe, Johannes
    Adam, Gerhard
    Bannas, Peter
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (04): : 388 - 398
  • [38] Variability of 4D flow parameters when subjected to changes in MRI acquisition parameters using a realistic thoracic aortic phantom
    Montalba, Cristian
    Urbina, Jesus
    Sotelo, Julio
    Andia, Marcelo E.
    Tejos, Cristian
    Irarrazaval, Pablo
    Hurtado, Daniel E.
    Valverde, Israel
    Uribe, Sergio
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 1882 - 1892
  • [39] Impact of Respiratory Gating on Hemodynamic Parameters from 4D Flow MRI
    Denecken, Esteban
    Sotelo, Julio
    Arrieta, Cristobal
    Andia, Marcelo E.
    Uribe, Sergio
    APPLIED SCIENCES-BASEL, 2022, 12 (06):
  • [40] Radiomics-based aortic flow profile characterization with 4D phase-contrast MRI
    Huellebrand, Markus
    Jarmatz, Lina
    Manini, Chiara
    Laube, Ann
    Ivantsits, Matthias
    Schulz-Menger, Jeanette
    Nordmeyer, Sarah
    Harloff, Andreas
    Hansmann, Jochen
    Kelle, Sebastian
    Hennemuth, Anja
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10