Proposal of a diagnostic algorithm based on the use of pulse oximetry in obstructive sleep apnea

被引:2
|
作者
Borsini, Eduardo [1 ]
Nigro, Carlos Alberto [2 ]
机构
[1] Buenos Aires Hosp Britanico, Sleep & Ventilat Unit, 74 Perdriel, Buenos Aires, Argentina
[2] Hosp Aleman, Pulmonol Serv, Buenos Aires, Argentina
关键词
Sleep apnea syndromes; Oximetry; Diagnosis; Algorithms; AIRWAY PRESSURE TRIAL; ADULTS; INDEX; POLYSOMNOGRAPHY; QUESTIONNAIRE; VALIDATION; MANAGEMENT; MODERATE; CARE;
D O I
10.1007/s11325-022-02757-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose The aims of this study were to assess the cut-off values for oxygen desaturation index > 3% (ODI3) to confirm obstructive sleep apnea (OSA) in subjects undergoing polysomnography (PSG) and home-based respiratory polygraphy (RP), and to propose an algorithm based on pulse oximetry (PO) for initial management of patients with suspected OSA. Methods This was an observational, cross-sectional, retrospective study. ODI3 was used to classify subjects as healthy (no OSA = AHI < 5 or < 15 events/h) or unhealthy (OSA = AHI >= 5 or >= 15 events/h). On the PSG or experimental group (ExpG), we determined ODI3 cut-off values with 100% specificity (Sp) for both OSA definitions. ODI3 values without false positives in the Exp-G were applied to a validation group (Val-G) to assess their performance. A strategy based on PO was proposed in patients with suspected OSA. Results In Exp-G (PSG) 1141 patients and in Val-G (RP) 1141 patients were included. In Exp-G, ODI3 > 12 (OSA = AHI >= 5) had a sensitivity of 69.5% (CI95% 66.1-72.7) and Sp of 100% (CI95% 99-100), while an ODI3 > 26 had a 53.8% sensitivity (CI95% 49.3-58.2) and Sp of 100% (CI95% 99.4-100) for AHI >= 15. A high pretest probability for OSA by Berlin questionaire (> 2 categories) had a lower diagnostic performance than by STOP-BANG questionnaire >= 5 points (AHI > 5: 0.856 vs. 0.899, p < 0.001; AHI >= 15: 0.783 vs. 0.807, p 0.026). Conclusion We propose the initial use of PO at home in cases of moderate-to-high pretest probability of OSA. This algorithm considers PO as well as RP and PSG for more challenging cases or in case of doubt.
引用
收藏
页码:1677 / 1686
页数:10
相关论文
共 50 条
  • [31] Comparison of the Indices of Oxyhemoglobin Saturation by Pulse Oximetry in Obstructive Sleep Apnea Hypopnea Syndrome
    Lin, Chen-Liang
    Yeh, Chinson
    Yen, Chen-Wen
    Hsu, Wu-Huei
    Hang, Liang-Wen
    CHEST, 2009, 135 (01) : 86 - 93
  • [32] The role of nocturnal pulse oximetry in the screening for obstructive sleep apnea in obese children and adolescents
    Van Eyck, Annelies
    Lambrechts, Chinouk
    Vanheeswijck, Liesbeth
    Van Hoorenbeeck, Kim
    Haentjens, Dominique
    Boudewyns, An
    De Winter, Benedicte Y.
    Van Gaal, Luc
    De Backer, Wilfried
    Verhulst, Stijn L.
    SLEEP MEDICINE, 2015, 16 (11) : 1409 - 1412
  • [33] A novel, simple, and accurate pulse oximetry indicator for screening adult obstructive sleep apnea
    Nigro, Carlos Alberto
    Castano, Gonzalo
    Bledel, Ignacio
    Colombi, Alfredo
    Zicari, Maria Cecilia
    SLEEP AND BREATHING, 2022, 26 (03) : 1125 - 1134
  • [34] The role of nocturnal pulse oximetry in the screening for obstructive sleep apnea in obese children and adolescents
    Van Eyck, Annelies
    Vanheeswijck, Liesbeth
    Lambrechts, Chinouk
    Van Hoorenbeeck, Kim
    Boudewyns, An
    De Winter, Benedicte
    Van Gaal, Luc
    De Backer, Wilfried
    Verhulst, Stijn
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [35] Utility Of Nocturnal Pulse-Oximetry In Detecting Obstructive Sleep Apnea In Hospitalized Patients
    Kahn, D. A.
    Keith, S.
    Mather, P.
    Rubin, S.
    Reeves, G.
    Bonita, R.
    Resnick, L.
    Malloy, C.
    Hasan, N.
    Sharma, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [36] A novel, simple, and accurate pulse oximetry indicator for screening adult obstructive sleep apnea
    Carlos Alberto Nigro
    Gonzalo Castaño
    Ignacio Bledel
    Alfredo Colombi
    María Cecilia Zicari
    Sleep and Breathing, 2022, 26 : 1125 - 1134
  • [37] Value of pulse oximetry watch for diagnosing pediatric obstructive sleep apnea/hypopnea syndrome
    Ma, Jing-Ru
    Huang, Jing-Jing
    Chen, Qi
    Wu, Hai-Tao
    Xiao, Kuan-Lin
    Zhang, Yu-Tian
    ACTA OTO-LARYNGOLOGICA, 2018, 138 (02) : 175 - 179
  • [38] Obstructive Sleep Apnea Screening using Nonlinear Characteristics of Overnight Pulse Oximetry Recordings
    Schmittendorf, E.
    Schultheiss, B.
    Goffart, M.
    Boehning, N.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 724 - 727
  • [39] Nocturnal pulse oximetry as an abbreviated testing modality for pediatric obstructive sleep apnea (OSA)
    Brouillette, RT
    Morielli, A
    Leimanis, A
    Waters, KA
    Luciano, R
    Ducharme, FM
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A485 - A485
  • [40] Nocturnal pulse oximetry as a possible screening method for obstructive sleep apnea in infants with laryngomalacia
    Makhout, Sanae
    Boudewyns, An
    Van Hoorenbeeck, Kim
    Verhulst, Stijn
    Van Eyck, Annelies
    SLEEP MEDICINE, 2022, 90 : 91 - 95