A modified dual-ejector enhanced dual-evaporator transcritical CO2 refrigeration cycle: 4E (Energy, Exergy, economic and Environmental) assessment

被引:24
|
作者
Zou, Lingeng [1 ]
Liu, Ye [1 ]
Yu, Mengqi [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Transcritical CO 2 cycle; Dual; -evaporator; 4E assessment; Supermarket refrigeration; SYSTEM; OPTIMIZATION; EFFICIENCIES; SIMULATION; EXPANSION;
D O I
10.1016/j.enconman.2024.118181
中图分类号
O414.1 [热力学];
学科分类号
摘要
Recently, the transcritical CO2 refrigeration cycle shows advantages in supermarket refrigeration applications. However, there is high expansion work recovery potential due to its large pressure difference between the inlet and outlet of the expansion valve. Therefore, a dual-ejector enhanced dual-evaporator transcritical CO2 refrigeration cycle (DECRC) is presented in this paper to recover expansion work by using ejectors. The thermodynamic models based on the energy, exergy, economic and environmental analysis are developed to compare their performance with the basic transcritical CO2 refrigeration cycle (BCRC) and the ejector-enhanced transcritical CO2 refrigeration cycle (ECRC). The energy analysis results indicate that compared with the BCRC and ECRC, the cooling coefficient of performance (COPc) of DECRC improves by 49.7% and 27.2%, respectively. The exergy analysis results show that the exergy destruction of the expansion valves in BCRC, ECRC and DECRC is 22.6%, 14.2% and 0.8%, respectively, which demonstrates that the introduction of the ejector could effectively reduce the exergy destruction of the cycle. The economic analysis results reveal that the cost per unit of exergy production by DECRC is 33.2% and 21.5% lower than that of BCRC and ECRC, respectively, while the impact of using ejectors on the total cost of the system is small 16.1%. The environmental analysis demonstrates that the carbon emission of DECRC is 33.2% and 21.4% lower than that of the BCRC and ECRC, respectively, under the given condition. Furthermore, the DECRC could obtain higher performance improvement when the ambient temperature is higher or the evaporating temperature is lower, indicating that the DECRC has a promising application in supermarket refrigeration.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Techno-economic feasibility of CO2 utilization in sustainable energy harvesting: Energy-Exergy-Economic-Environmental (4E) analysis
    Kannaiyan, Kumaran
    Sharma, Bhawandeep
    ENERGY CONVERSION AND MANAGEMENT-X, 2024, 24
  • [22] Energy, Exergy, Economic and Environmental (4E) analysis of integrated direct air capture and CO2 methanation under uncertainty
    Coppitters, Diederik
    Costa, Alexis
    Chauvy, Remi
    Dubois, Lionel
    De Paepe, Ward
    Thomas, Diane
    De Weireld, Guy
    Contino, Francesco
    FUEL, 2023, 344
  • [23] Comparative study on four autocascade refrigeration cycles based on energy, exergy, economic and environmental (4E) analyses
    Chen, Jiaheng
    Zhang, Zhenya
    Wang, Dingbiao
    Wang, Guanghui
    Peng, Xu
    Qin, Xiang
    Li, Hang
    ENERGY CONVERSION AND MANAGEMENT, 2023, 288
  • [24] A parametric study on energy, exergy and exergoeconomic assessments of a modified auto-cascade refrigeration cycle supported by a dual evaporator refrigerator
    Karacayli, Ibrahim
    Altay, Lutfiye
    Hepbasli, Arif
    ENERGY, 2024, 291
  • [25] Energy and exergy performance investigation of a transcritical CO2 vapor ejector-based refrigeration system for marine provision plants
    Syngounas, Evangelos
    Tsimpoukis, Dimitrios
    Bellos, Evangelos
    Koukou, Maria K.
    Tzivanidis, Christos
    Vrachopoulos, Michail Gr.
    APPLIED THERMAL ENGINEERING, 2025, 269
  • [26] Thermodynamic and exergoeconomic performance assessment of a SOFC/GT cogeneration system integrating transcritical CO2 cycle and ejector refrigeration cycle
    Xu, Chaoyi
    Ye, Jingjing
    Jie, Hao
    Liao, Jiawei
    Teng, Haowen
    Hong, Weirong
    APPLIED THERMAL ENGINEERING, 2025, 270
  • [27] Thermodynamic analysis of an enhanced ejector vapor injection refrigeration cycle for CO2 transcritical operation at low evaporating temperatures
    Gutierrez, Miguel Avila
    Perez, Bernardo Peris
    Munoz, Fernando Dominguez
    Besagni, Giorgio
    Lissen, Jose Manuel Salmeron
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 165 : 257 - 276
  • [28] Self-condensing transcritical CO2 cogeneration system with extraction turbine and ejector refrigeration cycle: A techno-economic assessment study
    Liu, Zhan
    Liu, Zihui
    Cao, Xing
    Li, Hailong
    Yang, Xiaohu
    ENERGY, 2020, 208 (208)
  • [29] Energy, exergy, economic and environmental (4E) analysis using a heat pump ejector dryer for cold climate condition
    Abadi, Majid Kheir
    Deymi-Dashtebayaz, Mahdi
    Ghorbani, Sobhan
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 59
  • [30] Experimental study on energy, exergy, and exergoeconomic analyses of a novel compression/ejector transcritical CO2 heat pump system with dual heat sources
    Zhang, Yuxiang
    Wei, Xinli
    Qin, Xiang
    ENERGY CONVERSION AND MANAGEMENT, 2022, 271