Hard X-ray full-field nanoimaging using a direct photon-counting detector

被引:5
|
作者
Flenner, Silja [1 ]
Hagemann, Johannes [2 ]
Wittwer, Felix [2 ,4 ]
Longo, Elena [1 ,5 ]
Kubec, Adam [3 ,6 ]
Rothkirch, Andre [2 ]
David, Christian [3 ]
Mueller, Martin [1 ]
Greving, Imke [1 ]
机构
[1] Helmholtz Zentrum Hereon, Max Planck Str 1, D-21502 Geesthacht, Germany
[2] DESY, Ctr Xray & Nano Sci CXNS, Notkestr 85, D-22607 Hamburg, Germany
[3] Paul Scherrer Inst, Forsch Str 111, CH-5232 Villigen, Switzerland
[4] Lawrence Berkeley Natl Lab, NERSC, Berkeley, CA 94720 USA
[5] Elettra Sincrotrone Trieste SCpA, I-34149 Trieste, Italy
[6] XRnanotech GmbH, Forsch Str 111, CH-5232 Villigen, Switzerland
关键词
nanotomography; full-field X-ray microscopy; near-field holography; near-field ptychography; Zernike phase contrast; singlephoton-counting detector; phase contrast; PHASE-CONTRAST; RESOLUTION; TOMOGRAPHY; HOLOGRAPHY; RETRIEVAL; NOISE;
D O I
10.1107/S1600577522012103
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Full-field X-ray nanoimaging is a widely used tool in a broad range of scientific areas. In particular, for low-absorbing biological or medical samples, phase contrast methods have to be considered. Three well established phase contrast methods at the nanoscale are transmission X-ray microscopy with Zernike phase contrast, near-field holography and near-field ptychography. The high spatial resolution, however, often comes with the drawback of a lower signal-to-noise ratio and significantly longer scan times, compared with microimaging. In order to tackle these challenges a single-photon-counting detector has been implemented at the nanoimaging endstation of the beamline P05 at PETRA III (DESY, Hamburg) operated by Helmholtz-Zentrum Hereon. Thanks to the long sample-to-detector distance available, spatial resolutions of below 100 nm were reached in all three presented nanoimaging techniques. This work shows that a single-photon-counting detector in combination with a long sample-todetector distance allows one to increase the time resolution for in situ nanoimaging, while keeping a high signal-to-noise level.
引用
收藏
页码:390 / 399
页数:10
相关论文
共 50 条
  • [31] Direct photon-counting scintillation detector readout using an SSPM
    Stapels, Christopher J.
    Squillante, Michael R.
    Lawrence, William G.
    Augustine, Frank L.
    Christian, James F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 87 - 90
  • [32] Development of an energy-binned photon-counting detector for X-ray and gamma-ray imaging
    Ogawa, Koichi
    Kobayashi, Toru
    Kaibuki, Futoshi
    Yamakawa, Tsutomu
    Nagano, Tatsuya
    Hashimoto, Daisuke
    Nagaoka, Hideyuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 664 (01): : 29 - 37
  • [33] Multi-Material Decomposition using Low-Current X-Ray and a Photon-Counting CZT Detector
    Kim, Sangtaek
    Hernandez, Andrew
    Alhassen, Fares
    Pivovaroff, Michael
    Cho, Hyo-Min
    Gould, Robert G.
    Seo, Youngho
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4735 - 4738
  • [34] X-Ray Transmittance Modeling-Based Material Decomposition Using a Photon-Counting Detector CT System
    Lee, Okkyun
    Rajendran, Kishore
    Polster, Christoph
    Stierstorfer, Karl
    Kappler, Steffen
    Leng, Shuai
    McCollough, Cynthia H.
    Taguchi, Katsuyuki
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (04) : 508 - 516
  • [35] Usefulness of an energy-binned photon-counting x-ray detector for dental panoramic radiographs
    Fukui, Tatsumasa
    Katsumata, Akitoshi
    Ogawa, Koichi
    Fujiwara, Shuu
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [36] Soft X-ray sensitivity of a photon-counting hybrid pixel detector with a silicon sensor matrix
    Fornaini, A
    Calvet, D
    Visschers, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (01): : 142 - 145
  • [37] X-ray photon-counting detector based on a micro-channel plate for pulsar navigation
    Chen, Baomei
    Zhao, Baosheng
    Hu, Huijun
    Yan, Qiurong
    Sheng, Lizhi
    CHINESE OPTICS LETTERS, 2011, 9 (06)
  • [38] Novel Photon-Counting Energy-Resolving Ultra-Fast X-Ray Detector
    Ertosun, M. Guenhan
    Levin, Craig S.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [39] X-ray photon-counting detector based on a micro-channel plate for pulsar navigation
    陈宝梅
    赵宝升
    胡慧君
    鄢秋荣
    盛立志
    ChineseOpticsLetters, 2011, 9 (06) : 13 - 16
  • [40] Dual scanning and full-field hard x-ray microscopy with a laboratory source
    Blackhall, Cristoffer J.
    Morgan, Kaye S.
    Pelliccia, Daniele
    OPTICS EXPRESS, 2014, 22 (13): : 15437 - 15446