Non-Invasive Determination of the Mass Flow Rate for Particulate Solids Using Microwaves

被引:1
|
作者
Zoad, Amrit [1 ]
Koelpin, Alexander [2 ]
Penirschke, Andreas [1 ]
机构
[1] Univ Appl Sci Mittelhessen, High Frequency Technol, D-61169 Friedberg, Germany
[2] Hamburg Univ Technol, Inst High Frequency Technol, D-21073 Hamburg, Germany
关键词
mass flow rate; measurement technique; solid concentration determination; non-invasive sensor; velocity detection;
D O I
10.3390/s23249821
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a novel technique for the mass flow rate determination of particulate solids called the "Sliding Mass Technique". The mass flow rate is a measure of the mass of a substance that passes through a given cross-sectional area per unit time. Its calculation requires simultaneous detection of the concentration and velocity of the Material Under Test. A novel measurement technique is designed for determining the concentration of the mass flow without the necessity for density evaluation. The mass flow rate is determined by fusing the established concentration results with velocity results obtained from "Microwave Spatial Filtering Velocimetry". A new metamaterial-based mass flow sensor for particulate solids was designed, realized and measured in an industrial environment. A Software-Defined Radio (Ettus Research (TM)'s USRP B210) was utilized as a sensor electronic system for DAQ purposes. A MATLAB app was developed to operate the SDR. Measurements were carried out on-site using a state-of-the-art wood pellet heating system with wood pellets with different moisture contents. The measurement results were found to be in very good agreement with the expected results, which strengthens the feasibility of this newly proposed measurement technique.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Non-invasive thermal energy flow rate sensor for turbulent pipe flows
    Alanazi, Mohammed A.
    Diller, Thomas E.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2022, 88
  • [22] NON-INVASIVE MEASUREMENT OF BLOOD FLOW-RATE IN EXPANDED POLYTETRAFLUOROETHYLENE GRAFTS
    RITTGERS, SE
    GARCIAVALDEZ, C
    MCGUIGAN, JA
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1985, 9 (01) : 1 - 4
  • [23] A NEW METHOD FOR NON-INVASIVE BEDSIDE DETERMINATION OF PULMONARY BLOOD-FLOW
    GEDEON, A
    FORSLUND, L
    HEDENSTIERNA, G
    ROMANO, E
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (04) : 411 - 418
  • [24] Measurement of mass flow rate of particulate solids in gravity chute conveyor based on laser sensing array
    Zheng, Yingna
    Li, Yang
    Liu, Qiang
    OPTICS AND LASER TECHNOLOGY, 2007, 39 (02): : 298 - 305
  • [25] NON-INVASIVE DETERMINATION OF PULMONIC TO SYSTEMIC FLOW RATIO BY PULSED DOPPLER ECHO
    STEVENSON, JG
    KAWABORI, I
    CIRCULATION, 1982, 66 (04) : 232 - 232
  • [26] TECHNIQUE FOR NON-INVASIVE DETERMINATION OF PATENCY AND FLOW VELOCITY IN ARTERIOVENOUS SHUNTS AND FISTULAS
    BERNSTEIN, EF
    FRONEK, A
    CIRCULATION, 1975, 52 (04) : 160 - 160
  • [27] Heart Rate Measurement Using Non-invasive Sparse Signal Approach
    Shuaibu, Aliyu Nuhu
    Dajab, Danjuma D.
    Usman, Fahad
    2020 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT AND ADVANCED SYSTEMS (ICIAS), 2021,
  • [28] Microwave Mass Flow Meter for Pneumatic Conveyed Particulate Solids
    Penirschke, Andreas
    Puentes, Margarita
    Maune, Holger
    Schuessler, Martin
    Gaebler, Alexander
    Jakoby, Rolf
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 564 - 569
  • [29] Moisture Insensitive Microwave Mass Flow Detector for Particulate Solids
    Penirschke, Andreas
    Angelovski, Aleksandar
    Jakoby, Rolf
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,
  • [30] A non-invasive heart rate prediction method using a convolutional approach
    Karapinar, Ercument
    Sevinc, Ender
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, : 901 - 914