Comparative Analysis of Supplemental Medial Buttress Plate Fixation for High-Energy Displaced Femoral Neck Fractures in Young Adults

被引:4
|
作者
Collinge, Cory A. [1 ]
Harris, Payton [1 ]
Sagi, H. Claude [2 ]
Rodriguez-Buitrago, Andres [3 ,4 ]
Beltran, Michael M. [2 ]
Mitchell, Phillip R. [3 ]
Mir, Hassan F. [5 ,6 ]
Lebus, George [7 ]
Tornetta, Paul, III [8 ]
de la Fuente, Guadalupe [1 ]
机构
[1] Ft Worth Orthoped Trauma Surg, Ft Worth, TX USA
[2] Univ Cincinnati, Dept Orthoped Surg, Cincinnati, OH USA
[3] Vanderbilt Univ, Med Ctr, Dept Orthopaed Surg, Nashville, TN USA
[4] Fdn Santa Fe Bogota, Dept Orthopaed Surg, Bogota, Colombia
[5] Florida Orthopaed Inst, Orthopaed Trauma Serv, Tampa, FL USA
[6] Univ S Florida, Tampa, FL 33620 USA
[7] Texas Orthopaed Associates, Ft Worth, TX USA
[8] Boston Univ, Med Ctr, Dept Orthoped Surg, Boston, MA USA
关键词
medial plate; buttress; plate; femoral neck; fracture; young; Pauwels; Smith-Petersen; BIOMECHANICAL ANALYSIS; INTERNAL-FIXATION; VARUS COLLAPSE; SHEAR; HIP; SCREW; AGES;
D O I
10.1097/BOT.0000000000002578
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives:To evaluate whether augmenting traditional fixation with a femoral neck buttress plate (FNBP) improves clinical outcomes in young adults with high-energy displaced femoral neck fractures.Design:Multicenter retrospective matched cohort comparative clinical study.Setting:Twenty-seven North American Level 1 trauma centers.Patients:Adult patients younger than 55 years who sustained a high-energy (nonpathologic) displaced femoral neck fracture.Intervention:Operative reduction and stabilization of a displaced femoral neck fracture with (group 1) and without (group 2) an FNBP.Main Outcome Measurements:Complications including failed fixation, nonunion, osteonecrosis, malunion, and need for subsequent major reconstructive surgery (early revision of reduction and/or fixation), proximal femoral osteotomy, or arthroplasty.Results:Of 478 patients younger than 55 years treated operatively for a displaced femoral neck fracture, 11% (n = 51) had the definitive fixation augmented with an FNBP. One or more forms of treatment failure occurred in 29% (n = 15/51) for group 1 and 49% (209/427) for group 2 (P < 0.01). When FNBP fixation was used, mini-fragment (2.4/2.7 mm) fixation failed significantly more often than small-fragment (3.5 mm) fixation (42% vs. 5%, P < 0.01). Irrespective of plate size, anterior and anteromedial plates failed significantly more often than direct medial plates (75% and 33% vs. 9%, P < 0.001).Conclusions:The use of a femoral neck buttress plate to augment traditional fixation in displaced femoral neck fractures is associated with improved clinical outcomes, including lower rates of failed fixation, nonunion, osteonecrosis, and need for secondary reconstructive surgery. The benefits of this technique are optimized when a small-fragment (3.5 mm) plate is applied directly to the medial aspect of the femoral neck, avoiding more anterior positioning.
引用
收藏
页码:207 / 213
页数:7
相关论文
共 50 条
  • [21] Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures
    Onder, Yilmaz
    Bulut, Tugrul
    Eroglu, Osman Nuri
    Ciklacandir, Samet
    Isler, Yalcin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (06)
  • [22] Treatment of old femoral neck fractures in young adults with a medial buttress plate combined with three cannulated screws and iliac autograft: Surgical technique and preliminary results
    Zhao, Guanglei
    Chen, Wenjun
    Wu, Jianguo
    Ma, Tiancong
    Wang, Siqun
    Wei, Yibing
    Xia, Jun
    Huang, Gangyong
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (04)
  • [23] Prospective and Comparative Analysis of Internal Fixation of Femoral Neck Fractures With or Without Vascularized Iliac Graft in Young Adults
    Yu, Xiao-bing
    Zhao, De-wei
    Zhong, Shi-zhen
    Liu, Bao-yi
    Wang, Ben-jie
    Liu, Yu-peng
    Zhang, Yao
    Cui, Da-ping
    Fu, Da-peng
    Xie, Hui
    ORTHOPEDICS, 2013, 36 (02) : E132 - E138
  • [24] Effect of integrity of the posterior cortex in displaced femoral neck fractures on outcome after surgical fixation in young adults
    Huang, Tsan-Wen
    Hsu, Wei-Hsiu
    Peng, Kuo-Ti
    Lee, Ching-Yu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (02): : 217 - 222
  • [25] Vascularized iliac bone graft for displaced femoral neck fractures in young adults
    Chang, MC
    Lo, WH
    Chen, TH
    ORTHOPEDICS, 1999, 22 (05) : 493 - 499
  • [26] FUNCTIONAL AND RADIOLOGICAL EVALUATIONS OF HIGH-ENERGY TIBIAL PLATEAU FRACTURES TREATED WITH DOUBLE-BUTTRESS PLATE FIXATION
    Yu, Z.
    Zheng, L.
    Zhang, Y.
    Li, J.
    Ma, B.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2009, 14 (05) : 200 - 205
  • [27] Femoral neck fracture in a young person - ORIF but do we use a medial buttress plate as well on the femoral neck? OTG 23
    Giordano, Vincenzo
    Rayes, Johnny
    Buckley, R. E.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (12): : 3867 - 3868
  • [28] RESULTS OF DELAYED FIXATION OF DISPLACED FEMORAL NECK FRACTURES IN ADULTS: A RETROSPECTIVE CLINICAL STUDY
    Pal, Utkarsh
    Choubey, Raghvendra
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (57): : 9883 - 9888
  • [29] Functional and radiological evaluations of high-energy tibial plateau fractures treated with double-buttress plate fixation
    Z Yu
    L Zheng
    Y Zhang
    J Li
    B Ma
    European Journal of Medical Research, 14
  • [30] OSTEOSYNTHESIS OF MEDIAL FRACTURES OF FEMORAL-NECK BY SLIDING NAIL-PLATE FIXATION
    FRANDSEN, PA
    JORGENSEN, F
    ACTA ORTHOPAEDICA SCANDINAVICA, 1977, 48 (01): : 57 - 62