Numerical simulation of microchannel heat exchanger using CFD

被引:5
|
作者
Anjaneya, G. [1 ]
Sunil, S. [2 ]
Kakkeri, Shrishail [3 ]
Math, Mahantesh M. [1 ]
Vaibhav, M. N. [4 ]
Solaimuthu, C. [5 ]
Prasad, C. Durga [5 ]
Vasudev, Hitesh [6 ]
机构
[1] RV Coll Engn, Dept Mech Engn, Bengaluru, Karnataka, India
[2] Sri Venkateshwara Coll Engn, Dept Mech Engn, Bengaluru, Karnataka, India
[3] CF CNC Grp Ind, Peenya 2nd Stage, Bengaluru, Karnataka, India
[4] Indian Inst Sci, Bengaluru, Karnataka, India
[5] RV Inst Technol & Management, Dept Mech Engn, Bengaluru, Karnataka, India
[6] Lovely Profess Univ, Phagwara, India
关键词
Heat sink; Computation fluid dynamics; Microchannel heat exchanger; CHANNEL GEOMETRY; WEAR BEHAVIOR; FLOW; PERFORMANCE; PARAMETERS;
D O I
10.1007/s12008-023-01376-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Modern electronic devices include faster processing times and greater compactness. Heat generation rises as a result of miniaturization and higher power density. The working temperature of electronic components increases beyond their critical limits as a result of increased heat generation. Higher temperatures cause the components to perform poorly and occasionally fail. In order to avoid failures and maintain the long-term dependability of electronic devices, an effective cooling technique is required. One potential solution for this is to use microchannel heat sinks to reduce the temperature of integrated chips (ICs). To get the best design, it is crucial to do thermal analyses on various channel layouts and their cross sections and compare how they operate. In this study, a microchannel heat sink's effectiveness at dissipating heat was examined with respect to its hydraulic diameter, surface area and number of channels using the commercial computational fluid dynamics (CFD) software ANSYS Fluent. Numerical analysis of four alternative 3D heat sinks employing water as a coolant was performed. A laminar and incompressible fluid model was used to conduct steady-state analysis. The simulations were carried out with boundary conditions of a constant mass flow rate of 0.00623875 kg/s and a constant flux of 143,000 W/m(2) for all the models. The results of the study showed that the surface temperature decreased with an increase in cross-sectional area, number of channels and hydraulic diameter from 361 K for a simple rectangular model to 332 K, 326 K, and 324 K for a 5-channel fin, 8-channel fin and 11-channel fin model, respectively. The 8-channel fin model was found to have the best overall heat transfer coefficient compared with the other models, with an increase of 188% above the basic rectangular model.
引用
收藏
页码:5847 / 5863
页数:17
相关论文
共 50 条
  • [21] Numerical Simulation of Different Models of Heat Pipe Heat Exchanger Using AcuSolve
    Zainal, Nurul Amira
    Sulaiman, Saiful Naim
    Shamsudin, Mohd Afdhal
    Waini, Iskandar
    ENGINEERING TECHNOLOGY INTERNATIONAL CONFERENCE 2016 (ETIC 2016), 2017, 97
  • [22] CFD numerical simulation of a U-tube ground heat exchanger used in ground source heat pumps
    Mechanical Engineering School, University of Science and Technology Beijing, Beijing 100083, China
    Beijing Keji Daxue Xuebao, 2007, 3 (329-333): : 329 - 333
  • [23] Numerical Simulation of Heat Transfer in Rectangular Microchannel
    Yao, Jun
    Yao, Yufeng
    Mason, Peter J.
    Patel, Mayur K.
    ADVANCES IN APPLIED MATHEMATICS AND MECHANICS, 2009, 1 (02) : 231 - 241
  • [24] Comparison of cooling performance of manifold and straight microchannel heat sinks using CFD simulation
    Zajac, Piotr
    2021 22ND INTERNATIONAL CONFERENCE ON THERMAL, MECHANICAL AND MULTI-PHYSICS SIMULATION AND EXPERIMENTS IN MICROELECTRONICS AND MICROSYSTEMS (EUROSIME), 2021,
  • [25] Numerical Simulation of Oscillating Heat Pipe Heat Exchanger
    Chai, Benyin
    Shao, Min
    Li, Xuanyou
    Zhou, Shenjie
    Shi, Yongchun
    INTERNATIONAL JOURNAL OF FOOD ENGINEERING, 2010, 6 (01)
  • [26] Numerical Study on the Performance of a Microchannel Heat Exchanger with a Novel Channel Army
    Jeon, Seung Won
    Lee, Kyu Jung
    Moon, Dong Ju
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2011, 35 (11) : 1119 - 1126
  • [27] Experimental and numerical study of the compact heat exchanger with different microchannel shapes
    Glazar, Vladimir
    Frankovic, Bernard
    Trp, Anica
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 51 : 144 - 153
  • [28] Numerical investigation of counter flow microchannel heat exchanger with MEPCM suspension
    Hasan, Mushtaq I.
    APPLIED THERMAL ENGINEERING, 2011, 31 (6-7) : 1068 - 1075
  • [29] CFD SIMULATION OF THE HEAT TRANSFER PROCESS IN A CHEVRON PLATE HEAT EXCHANGER USING THE SST TURBULENCE MODEL
    Skocilas, Jan
    Palaziuk, Ievgen
    ACTA POLYTECHNICA, 2015, 55 (04) : 267 - 274
  • [30] The Simulation of Temperature Distribution in a Ground Heat Exchanger-GHE Using the Autodesk CFD Simulation Program
    Gielzecki, Jan
    Jakubowski, Tomasz
    RENEWABLE ENERGY SOURCES: ENGINEERING, TECHNOLOGY, INNOVATION, 2018, : 333 - 343