Conditional-Extreme-Point Based Fault-Tolerant Predictive Control of Five-Phase PMSM With Low Switching Frequency

被引:2
|
作者
Wang, Huanan [1 ]
Zhao, Wenxiang [1 ]
Tao, Tao [1 ]
Kang, Mei [1 ]
Qian, Yuanfang [1 ]
机构
[1] Jiangsu Univ, Sch Elect & Informat Engn, Zhenjiang 212013, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Conditional extreme point; dual control set; fault-tolerant control; five-phase motor; model predictive control; reference voltage vector; DIRECT TORQUE CONTROL; MAGNET SYNCHRONOUS MACHINES; INDUCTION-MOTOR; CONTROL SCHEME; FLUX CONTROL; FCS-MPC; OPERATION;
D O I
10.1109/TIE.2022.3227236
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The virtual voltage vector based fault-tolerant control has been widely concerned, but suffering from the increased switching frequency and the reduced bus voltage utilization at the faulty operation. Also, the harmonic space is uncontrollable. This article proposes a conditional-extreme-point based fault-tolerant model predictive control for a five-phase permanent magnet synchronous motor. The conditional extreme point is used to predict the optimal reference voltage vector. First, to suppress the harmonics, dual control sets are established without the sacrifice of bus voltage utilization. Then, the unconditional extreme point and y-axis voltage are predicted to select the appropriate control set, and two adjacent vectors are preselected for generating the optimal reference voltage vector. Subsequently, the conditional extreme point of the cost function is calculated to obtain the optimal reference voltage vector. Due to the unemployment of the null vector, the switching frequency is greatly reduced. Finally, the experimental results are presented to verify the proposed control scheme.
引用
收藏
页码:11495 / 11506
页数:12
相关论文
共 50 条
  • [41] Fault-tolerant Control Strategy of Five-phase Permanent Magnet Synchronous Motor
    Wang, Ranran
    Tao, Caixia
    Gao, Fengyang
    Wang, Weibin
    Zhang, Jiangang
    2021 8TH INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION, IFEEA, 2021, : 577 - 582
  • [42] Fault-tolerant control strategy for five-phase permanent magnet synchronous motor
    Gao, Hong-Wei
    Yang, Gui-Jie
    Liu, Jian
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2014, 18 (06): : 61 - 65
  • [43] FCS-MPC-Based Fault-Tolerant Control of Five-Phase IPMSM for MTPA Operation
    Liu, Guohai
    Song, Chengyan
    Chen, Qian
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (03) : 2882 - 2894
  • [44] Fault-Tolerant Control Using the GA Optimization Considering the Reluctance Torque of a Five-Phase Flux Switching Machine
    Ben Sedrine, E.
    Ojeda, J.
    Gabsi, M.
    Slama-Belkhodja, I.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (03) : 927 - 938
  • [45] Fault-Tolerant Predictive Control of Six-Phase PMSM Drives Based on Pulsewidth Modulation
    Lu, Hanxiao
    Li, Jian
    Qu, Ronghai
    Ye, Donglin
    Lu, Yang
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (07) : 4992 - 5003
  • [46] Robust Predictive Current Control for Fault-Tolerant Operation of Five-Phase PM Motors Based on Online Stator Inductance Identification
    An, Xingke
    Liu, Guohai
    Chen, Qian
    Zhao, Wenxiang
    Song, Xiangjin
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (11) : 13162 - 13175
  • [47] Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with Inverter Faults
    Meinguet, Fabien
    Ngac-Ky Nguyen
    Sandulescu, Paul
    Kestelyn, Xavier
    Semail, Eric
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 5191 - 5196
  • [48] Model Predictive Current Control of Open-Circuit Fault-Tolerant Five-Phase Flux-Switching Permanent Magnet Motor Drives
    Huang, Wentao
    Hua, Wei
    Chen, Fuyang
    Yin, Fangbo
    Qi, Ji
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2018, 6 (04) : 1840 - 1849
  • [49] Open-circuit Fault-tolerant Strategies for a Five-phase Flux-switching Permanent Magnet Motor Based on Model Predictive Torque Control Method
    Chen F.
    Hua W.
    Huang W.
    Zhu J.
    Tong M.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (02): : 337 - 346
  • [50] Fault-tolerant five-phase permanent magnet motor drives
    Parsa, L
    Toliyat, HA
    CONFERENCE RECORD OF THE 2004 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4: COVERING THEORY TO PRACTICE, 2004, : 1048 - 1054